The efficacy of real-time 3-dimensional echocardiography for right ventricular biopsy

被引:6
作者
Aggarwal, M
Drachenberg, C
Douglass, L
DeFilippi, C
机构
[1] Univ Maryland, Div Cardiol, Med Ctr, Baltimore, MD 21201 USA
[2] Univ Maryland, Dept Pathol, Med Ctr, Baltimore, MD 21201 USA
关键词
D O I
10.1016/j.echo.2005.04.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In recipients of cardiac transplant, repetitive right ventricular (RV) biopsies can result in decreased sample quality as a consequence of fibrosis from oversampling specific locations. Real-time 3-dimensional echocardiography (RT3D) is a new imaging modality that may precisely guide bioptome placement and, therefore, is a potential alternative to fluoroscopy (FI). We sought to determine if a RT3D-guided biopsy procedure would result in a comparable or decreased incidence of fibrosis versus Fl. Methods: Fifteen patients underwent 32 RV biopsy procedures with an equal number by each technique. RT3D was performed from the apical 4-chamber position. Fl was performed with biplane images. With both RT3D and Fl, attempts were made to vary bioptome position with each sample. A pathologist determined the percent fibrosis, with a biopsy sample containing 50% or more fibrosis considered uninterpretable for rejection. Results. RT3D provided excellent visualization of the distal end of the bioptome within the right atrium and RV. A mean of 4.3 +/- 1.0 RV biopsy samples were collected per procedure with 64 samples obtained by Fl and 72 obtained by RT3D. In all, 13 samples (20.3%) by Fl versus 10 samples (13.9%) by RT3D (P =.45) contained fibrosis and 7 samples (10.9%) by Fl versus 4 samples (5.6%) were uninterpretable (P =.41). Two Fl- versus zero RT3D-guided procedures contained 75% or more uninterpretable samples (P =.47) and were, therefore, nondiagnostic. There were no complications. Conclusions: RT3D is a new modality to facilitate accurate localization of the bioptome in patients undergoing transplant providing comparable quality RV samples to that of biplane Fl.
引用
收藏
页码:1208 / 1212
页数:5
相关论文
共 12 条
[1]  
BARALDIJUNKINS C, 1993, J HEART LUNG TRANSPL, V12, P63
[2]  
Billingham M E, 1990, Semin Thorac Cardiovasc Surg, V2, P233
[3]  
CAVES PK, 1974, LANCET, V1, P821
[4]   COMPLICATIONS OF TRANSVENOUS RIGHT VENTRICULAR ENDOMYOCARDIAL BIOPSY IN ADULT PATIENTS WITH CARDIOMYOPATHY - A 7-YEAR SURVEY OF 546 CONSECUTIVE DIAGNOSTIC PROCEDURES IN A TERTIARY REFERRAL CENTER [J].
DECKERS, JW ;
HARE, JM ;
BAUGHMAN, KL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (01) :43-47
[5]   Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: A comparison with fluoroscopy [J].
McCreery, CJ ;
McCulloch, M ;
Ahmad, M ;
deFilippi, CR .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (09) :927-933
[6]  
MILLER LW, 1988, CIRCULATION, V78, P99
[7]   MANAGEMENT OF PATIENTS AFTER CARDIAC TRANSPLANTATION [J].
OLSON, LJ ;
RODEHEFFER, RJ .
MAYO CLINIC PROCEEDINGS, 1992, 67 (08) :775-784
[8]   Real-time three-dimensional echocardiography: An overview [J].
Panza, JA .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (03) :227-235
[9]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC GUIDING OF ENDOMYOCARDIAL BIOPSY [J].
PIERARD, L ;
ELALLAF, D ;
DORIO, V ;
DEMOULIN, JC ;
CARLIER, J .
CHEST, 1984, 85 (06) :759-762
[10]  
ROSE AG, 1986, ARCH PATHOL LAB MED, V110, P622