Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test-retest reliability

被引:3
作者
Simpson, Daniel [1 ]
Ehrensberger, Monika [1 ]
Nulty, Christopher [1 ]
Regan, Joanne [1 ]
Broderick, Patrick [1 ]
Blake, Catherine [2 ]
Monaghan, Kenneth [1 ]
机构
[1] Inst Technol, Sch Sci, Clin Hlth & Nutr Ctr CHANCE, Sligo, Ireland
[2] Univ Coll Dublin, Sch Publ Hlth Physiotherapy & Sports Sci, Dublin, Ireland
关键词
Reliability; strength testing; Biodex system 3; ankle dorsiflexion; elbow extension; STRENGTH MEASUREMENTS; INTRACLASS CORRELATIONS; MUSCLE STRENGTH; BIODEX; ELECTROMYOGRAPHY; VOLUNTARY; EXTENSOR; FLEXOR; SPEED;
D O I
10.1142/S1013702519500069
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Peak Torque (PT), Rate of Torque Development (RTD) and Average Torque (AT) over a single contraction assess the three components of muscle function during isometric contractions. Surprisingly, AT has never been reported or its reliability confirmed. Objectives: This study aims to establish protocol reliability for ankle dorsiflexion and elbow extension isometric muscle function (PT, RTD, AT) in healthy participants using the Biodex System 3 Dynamometer. Methods: Twelve participants (6 male, 6 female, mean age 39.8 +/- 16.0 years) performed four maximal isometric contractions on two occasions. Intraclass Correlation Coefficient (ICC), Typical Error (TE) and Coefficient of Variation (CV) for PT, RTD and AT were reported. Results: The ICC for all strength parameters varied from 0.98-0.92. TE for ankle dorsiflexion PT was 1.38 Nm, RTD 7.43 Nm/s and AT 1.33 Nm, CV varied from 6.26 +/- 6.25% to 11.72 +/- 8.27%. For elbow extension. TE was 3.36 Nm for PT, 14.87 Nm/s for RTD and 3.03 Nm for AT, CV varied from 5.97 +/- 4.52% to 18.46 +/- 14.78%. Conclusion: Maximal isometric ankle dorsiflexion and elbow extension PT, RTD and AT can be evaluated with excellent reliability when following the described protocol. This testing procedure, including the application of AT, can be confidently applied in research, exercise or clinical settings.
引用
收藏
页码:67 / 76
页数:10
相关论文
共 42 条
  • [31] Test-retest reliability of a single isometric mid-thigh pull protocol to assess peak force and strength-endurance
    Grover, Zak
    McCormack, James
    Cooper, Jonathan
    Fisher, James P.
    PEERJ, 2024, 12
  • [32] Hip Abductor Rate of Torque Development as Opposed to Isometric Strength Predicts Peak Knee Valgus During Landing: Implications for Anterior Cruciate Ligament Injury
    Stearns-Reider, Kristen M.
    Straub, Rachel K.
    Powers, Christopher M.
    JOURNAL OF APPLIED BIOMECHANICS, 2021, 37 (05) : 471 - 476
  • [33] Neural, biomechanical, and physiological factors involved in sex-related differences in the maximal rate of isometric torque development
    Inglis, J. Greig
    McIntosh, Kyle
    Gabriel, David A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2017, 117 (01) : 17 - 26
  • [34] Neural, biomechanical, and physiological factors involved in sex-related differences in the maximal rate of isometric torque development
    J. Greig Inglis
    Kyle McIntosh
    David A. Gabriel
    European Journal of Applied Physiology, 2017, 117 : 17 - 26
  • [35] Symmetry of electromechanical delay, peak torque and rate of force development in knee flexors and extensors in female and male subjects
    Szpala, Agnieszka S
    Rutkowska-Kucharska, Alicja
    Stawiany, Mateusz
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2015, 17 (01) : 61 - 68
  • [36] Muscle and tendon stiffness and belly gearing positively correlate with rate of torque development during explosive fixed end contractions
    Monte, Andrea
    Zignoli, Andrea
    JOURNAL OF BIOMECHANICS, 2021, 114
  • [37] Intra- and Inter-Rater Reliability of a Well-Used and a Less-Used IsoMed 2000 Dynamometer for Knee Flexion and Extension Peak Torque Measurements in a Concentric Test in Athletes
    Kocahan, Tugba
    Akinoglu, Bihter
    Yilmaz, Ayfer Ezgi
    Rosemann, Thomas
    Knechtle, Beat
    APPLIED SCIENCES-BASEL, 2021, 11 (11):
  • [38] Data-Driven Recommendations for Assessing the Early-Phase Rate of Torque Development: An Intersession Reliability Study in Physically Active Men and Women
    Speedtsberg, Merete Brink
    Zebis, Mette Kreutzfeldt
    Andersen, Lars Louis
    Sondergaard, Rasmus
    Holmich, Per
    Aagaard, Per
    Bencke, Jesper
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2025, 35 (03)
  • [39] Test-retest reliability of knee extensor rate of velocity and power development in older adults using the isotonic mode on a Biodex System 3 dynamometer
    Van Driessche, Stijn
    Van Roie, Evelien
    Vanwanseele, Benedicte
    Delecluse, Christophe
    PLOS ONE, 2018, 13 (05):
  • [40] Knee flexor strength, rate of torque development and flexibility in women and men with patellofemoral pain: Relationship with pain and the performance in the single leg bridge test
    Maiolini Ducatti, Matheus Henrique
    Waiteman, Marina Cabral
    Balotari Botta, Ana Flavia
    Lopes, Helder dos Santos
    Glaviano, Neal Robert
    de Azevedo, Fabio Micolis
    Briani, Ronaldo Valdir
    PHYSICAL THERAPY IN SPORT, 2021, 50 : 166 - 172