Showering Thermal Sensation in Residential Bathrooms

被引:5
作者
Wong, Ling-Tim [1 ]
Mui, Kwok-Wai [1 ]
Chan, Yiu-Wing [1 ]
机构
[1] Hong Kong Polytech Univ, Res Inst Smart Energy, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
关键词
thermal sensation; thermal environment; showering; residential bathroom; hot water; COMFORT; WATER;
D O I
10.3390/w14192940
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermal energy consumed by showering to the satisfaction of the showering subject, is largely dependent on the water temperature, shower duration, water flow rate, and bathroom air temperature. A research gap, between human thermal preferences and the smart use of thermal energy in high-rise urban residential bathroom environments, has been identified. This study examines the influence of a bathroom's thermal environment on the showering subject's thermal sensation. Of the 98 invited respondents, a total of 31 volunteers (12 females and 19 males) participated in the showering experiments, under three thermal conditions (control, colder, and warmer); their subjective thermal responses, including thermal sensation, thermal comfort, and thermal acceptability votes, were recorded. The results showed a non-linear trend of thermal sensation vote (TSV) against the bathroom air temperature. The predicted dissatisfied (PD) was asymmetrical, and the showering subjects preferred a slightly warm environment. Although the female TSV values were more sensitive than the male ones, in both the colder and warmer experiments, there were no significant gender differences. The findings of this study-including the expressions derived from the shower-water and bathroom air temperatures for the thermal comfort zone in a bathroom environment-can be used as a reference to enhance our understanding of thermal energy consumption in environmental design, and to help optimize the thermal environment in bathrooms.
引用
收藏
页数:9
相关论文
共 17 条
[1]  
Cheng C.L., 2005, J ASIAN ARCHIT BUILD, V4, P259, DOI [10.3130/jaabe.4.259, DOI 10.3130/JAABE.4.259]
[2]  
FANGER PO, 1973, BRIT J IND MED, V30, P313
[3]  
Hashiguchi Nobuko, 2002, Journal of Physiological Anthropology and Applied Human Science, V21, P277, DOI 10.2114/jpa.21.277
[4]   HUMANS UNDER SHOWERS - THERMAL SENSITIVITY, THERMONEUTRAL SENSATIONS, AND COMFORT ESTIMATES [J].
HERRMANN, C ;
CANDAS, V ;
HOEFT, A ;
GARREAUD, I .
PHYSIOLOGY & BEHAVIOR, 1994, 56 (05) :1003-1008
[5]  
Kanda Kiyoko, 1996, Applied Human Science, V15, P19, DOI 10.2114/jpa.15.19
[6]   An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings [J].
Lai, A. C. K. ;
Mui, K. W. ;
Wong, L. T. ;
Law, L. Y. .
ENERGY AND BUILDINGS, 2009, 41 (09) :930-936
[7]   Thermal and cardiovascular responses and thermal sensation during hot-water bathing and the influence of room temperature [J].
Masuda, Yuta ;
Marui, Shuri ;
Kato, Issei ;
Fujiki, Mayuka ;
Nakada, Mariko ;
Nagashima, Kei .
JOURNAL OF THERMAL BIOLOGY, 2019, 82 :83-89
[8]   Water and Energy Interactions [J].
McMahon, James E. ;
Price, Sarah K. .
ANNUAL REVIEW OF ENVIRONMENT AND RESOURCES, VOL 36, 2011, 36 :163-191
[9]   Efficient drain water heat recovery in horizontal domestic shower drains [J].
McNabola, Aonghus ;
Shields, Killian .
ENERGY AND BUILDINGS, 2013, 59 :44-49
[10]  
Moss K J., 2015, Heat and mass transfer in buildings