Comparison of methods for evaluation of wood smoke and estimation of UK ambient concentrations

被引:81
作者
Harrison, R. M. [1 ,2 ]
Beddows, D. C. S. [1 ]
Hu, L. [1 ]
Yin, J. [1 ]
机构
[1] Univ Birmingham, Sch Geog Earth & Environm Sci, Div Environm Hlth & Risk Management, Natl Ctr Atmospher Sci, Birmingham B15 2TT, W Midlands, England
[2] King Abdulaziz Univ, Ctr Excellence Environm Studies, Dept Environm Sci, Jeddah 21589, Saudi Arabia
基金
英国自然环境研究理事会;
关键词
FINE-PARTICLE EMISSIONS; PARTICULATE MATTER; CHEMICAL-CHARACTERIZATION; SOURCE APPORTIONMENT; ATMOSPHERIC AEROSOLS; FIREPLACE COMBUSTION; ORGANIC-COMPOUNDS; STOVE COMBUSTION; URBAN; POLLUTION;
D O I
10.5194/acp-12-8271-2012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Airborne concentrations of the wood smoke tracers, levoglucosan and fine potassium have been measured at urban and rural sites in the United Kingdom alongside measurements with a multi-wavelength aethalometer. The UK sites, and especially those in cities, show low ratios of levoglucosan to potassium in comparison to the majority of published data. It is concluded that there may be two distinct source types, one from wood stoves and fireplaces with a high organic carbon content, best represented by levoglucosan, the other from larger, modern appliances with a very high burn-out efficiency, best represented by potassium. Based upon levoglucosan concentrations and a conversion factor of 11.2 from levoglucosan to wood smoke mass, average concentrations of wood smoke including winter and summer sampling periods are 0.23 mu g m(-3) in Birmingham and 0.33 mu g m(-3) in London, well below concentrations typical of other northern European urban areas. There may be a further contribution from sources of potassium-rich emissions amounting to an estimated 0.08 mu g m(-3) in Birmingham and 0.30 mu g m(-3) in London. Concentrations were highly correlated between two London sites separated by 4 km suggesting that a regional source is responsible. Data from the aethalometer are either supportive of these conclusions or suggest higher concentrations, depending upon the way in which the data are analysed.
引用
收藏
页码:8271 / 8283
页数:13
相关论文
共 43 条
[1]  
[Anonymous], THESIS VIENNA U TECH
[2]   Temporal variation and impact of wood smoke pollution on a residential area in southern Germany [J].
Bari, Md Aynul ;
Baumbach, Guenter ;
Kuch, Bertram ;
Scheffknecht, Guenter .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (31) :3823-3832
[3]   Analysis of the air pollution climate at a central urban background site [J].
Bigi, Alessandro ;
Harrison, Roy M. .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (16) :2004-2012
[4]   Characterization of inorganic particulate matter from residential combustion of pelletized biomass fuels [J].
Boman, C ;
Nordin, A ;
Boström, D ;
Öhman, M .
ENERGY & FUELS, 2004, 18 (02) :338-348
[5]   Primary particle emissions from residential coal burning: Optical properties and size distributions [J].
Bond, TC ;
Covert, DS ;
Kramlich, JC ;
Larson, TV ;
Charlson, RJ .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2002, 107 (D21)
[6]   Variations in wood burning organic marker concentrations in the atmospheres of four European cities [J].
Caseiro, Alexandre ;
Oliveira, Cesar .
JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (08) :2261-2269
[7]   Wood burning impact on PM10 in three Austrian regions [J].
Caseiro, Alexandre ;
Bauer, Heidi ;
Schmidl, Christoph ;
Pio, Casimiro A. ;
Puxbaum, Hans .
ATMOSPHERIC ENVIRONMENT, 2009, 43 (13) :2186-2195
[8]   Toward a standardised thermal-optical protocol for measuring atmospheric organic and elemental carbon: the EUSAAR protocol [J].
Cavalli, F. ;
Viana, M. ;
Yttri, K. E. ;
Genberg, J. ;
Putaud, J. -P. .
ATMOSPHERIC MEASUREMENT TECHNIQUES, 2010, 3 (01) :79-89
[9]   What are the sources and conditions responsible for exceedences of the 24 h PM10 limit value (50 μg m-3) at a heavily trafficked London site? [J].
Charron, Aurelie ;
Harrison, Roy M. ;
Quincey, Paul .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (09) :1960-1975
[10]   Aerosol and trace gas vehicle emission factors measured in a tunnel using an Aerosol Mass Spectrometer and other on-line instrumentation [J].
Chirico, Roberto ;
Prevot, Andre S. H. ;
DeCarlo, Peter F. ;
Heringa, Maarten F. ;
Richter, Rene ;
Weingartner, Ernest ;
Baltensperger, Urs .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (13) :2182-2192