Separation of dansyl amino acid enantiomers by ligand-exchange capillary electrochromatography using an L-lysinamide-modified monolithic silica column

被引:5
|
作者
Nishiyama, T [1 ]
Chen, ZL [1 ]
Nakagama, T [1 ]
Uchiyama, K [1 ]
Hobo, T [1 ]
机构
[1] Tokyo Metropolitan Univ, Grad Sch Engn, Dept Appl Chem, Hachioji, Tokyo 1920397, Japan
关键词
chiral separation; capillary electrochromatography; monolithic column; dansyl amino acids; lysinamide;
D O I
10.2116/bunsekikagaku.52.1005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An L-lysinamide-modified monolithic column has been prepared by a sol-gel process and chemical modifications, and used for the enantioseparation of dansyl amino acids by both modes of capillary electrochromatography (CEC) and micro-high performance liquid chromatography (mu-HPLC). The electroosmotic flow (EOF), separation conditions and enantioselectivity have been investigated. The chiral selector of L-lysinamide loaded with Cu(II) ion generates a strong EOF, probably due to the nature of lysinamide containing two amino groups in a molecule. Besides, the separation behaviors in CEC and mu-HPLC have been compared.
引用
收藏
页码:1005 / 1009
页数:5
相关论文
共 50 条
  • [1] Cyclodextrin-modified monolithic columns for resolving dansyl amino acid enantiomers and positional isomers by capillary electrochromatography
    Chen, ZL
    Ozawa, H
    Uchiyama, K
    Hobo, T
    ELECTROPHORESIS, 2003, 24 (15) : 2550 - 2558
  • [2] Capillary electrochromatographic behaviors of dansyl amino acid enantiomers on a cyclodextrin-immobilized monolithic silica column
    Ozawa, H
    Chen, ZL
    Kawata, K
    Nakagama, T
    Uchiyama, K
    Hobo, T
    BUNSEKI KAGAKU, 2003, 52 (12) : 1105 - 1112
  • [3] Chemically L-phenylalaninamide-modified monolithic silica column prepared by a sol-gel process far enantioseparation of dansyl amino acids by ligand exchange-capillary electrochromatography
    Chen, ZL
    Hobo, T
    ANALYTICAL CHEMISTRY, 2001, 73 (14) : 3348 - 3357
  • [4] Chiral separation of amino acids by ligand-exchange capillary electrochromatography using continuous beds
    Schmid, MG
    Grobuschek, N
    Tuscher, C
    Gübitz, G
    Végvári, A
    Machtejevas, E
    Maruska, A
    Hjertén, S
    ELECTROPHORESIS, 2000, 21 (15) : 3141 - 3144
  • [5] Chemically L-prolinamide-modified monolithic silica column for enantiomeric separation of dansyl amino acids and hydroxy acids by capillary electrochromatography and μ-high performance liquid chromatography
    Chen, ZL
    Hobo, T
    ELECTROPHORESIS, 2001, 22 (15) : 3339 - 3346
  • [6] Chiral ligand-exchange separation and determination of malic acid enantiomers in apple juice by open-tubular capillary electrochromatography
    Aydogan, Cemil
    Karakoc, Veyis
    Denizli, Adil
    FOOD CHEMISTRY, 2015, 187 : 130 - 134
  • [7] Chiral separation of dansyl amino acids by ligand exchange capillary electrochromatography in a low molecular weight organogel
    Mizrahi, Shaul
    Rizkov, Dan
    Shames, Alexander I.
    Lev, Ovadia
    ELECTROPHORESIS, 2008, 29 (18) : 3941 - 3948
  • [8] Fast chiral separation by ligand-exchange HPLC using a dynamically coated monolithic column
    Schmid, Martin G.
    Schreiner, Karin
    Reisinger, Daniela
    Guebitz, Gerald
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (10) : 1470 - 1475
  • [9] Enantioseparation of dansyl amino acids by ligand-exchange capillary electrophoresis with zinc(II)-L-phenylalaninamide complex
    Qi, Li
    Yang, Gengliang
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) : 3209 - 3214
  • [10] Chiral separation of underivatized and dansyl amino acids by ligand-exchange micellar electrokinetic capillary chromatography using a copper(II)-L-valine complex as selector
    Zheng, ZX
    Lin, JM
    Qu, F
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1007 (1-2) : 189 - 196