Three-dimensional active imaging with maximum depth range

被引:32
|
作者
Zhang, Xiuda [1 ]
Yan, Huimin [1 ]
机构
[1] Zhejiang Univ, State Key Lab Modern Opt Instruments, NERC Opt Instruments, Dept Opt Engn, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
LASER;
D O I
10.1364/AO.50.001682
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In traditional three-dimensional (3D) active imaging methods, the detection depth range is observed to increase linearly with the detection time, and the intensity information was not fully utilized. However, by encoding the relative values into pseudovalues, the intensity information was fully utilized, and we found the maximum detection depth range increases exponentially with the detection time. Furthermore, we present a 3D imaging system capable of exponentially expanding the detection depth range. A 3D scene reconstruction was undertaken with the targets placed at a distance of 600-1100m. Experimental results indicate that the method expands the detection depth range exponentially without distance resolution loss as compared with the conventional method. (C) 2011 Optical Society of America
引用
收藏
页码:1682 / 1686
页数:5
相关论文
共 50 条
  • [31] Three-Dimensional Additively Manufactured Microstructures and Their Mechanical Properties
    Rodgers, Theron M.
    Lim, Hojun
    Brown, Judith A.
    JOM, 2020, 72 (01) : 75 - 82
  • [32] Three-dimensional theory of the magneto-optical trap
    Prudnikov, O. N.
    Taichenachev, A. V.
    Yudin, V. I.
    JOURNAL OF EXPERIMENTAL AND THEORETICAL PHYSICS, 2015, 120 (04) : 587 - 594
  • [33] Noncontact three-dimensional laser measuring device for tracheoscopy
    Müller, A
    Schubert, M
    Beleites, E
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (09) : 821 - 827
  • [34] Three-dimensional surfaces reconstruction base on laser triangulation
    Lizcano, C
    Márquez, M
    RIAO/OPTILAS 2004: 5TH IBEROAMERICAN MEETING ON OPTICS AND 8TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, PTS 1-3: ICO REGIONAL MEETING, 2004, 5622 : 1322 - 1327
  • [35] Three-dimensional measurement endoscope system with virtual rulers
    Nakatani, Hiromasa
    Abe, Keiichi
    Miyakawa, Atsuo
    Terakawa, Susumu
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (05)
  • [36] Three-dimensional theory of weakly nonlinear Compton scattering
    Albert, F.
    Anderson, S. G.
    Gibson, D. J.
    Marsh, R. A.
    Siders, C. W.
    Barty, C. P. J.
    Hartemann, F. V.
    PHYSICS OF PLASMAS, 2011, 18 (01)
  • [37] Three-Dimensional Plasmonic Micro Projector for Light Manipulation
    Chang, Chia Min
    Tseng, Ming Lun
    Cheng, Bo Han
    Chu, Cheng Hung
    Ho, You Zhe
    Huang, Hsin Wei
    Lan, Yung-Chiang
    Huang, Ding-Wei
    Liu, Ai Qun
    Tsai, Din Ping
    ADVANCED MATERIALS, 2013, 25 (08) : 1118 - 1123
  • [38] Multi-scale band-limited illumination profilometry for robust three-dimensional surface imaging at video rate
    Jiang, Cheng
    Kilcullen, Patrick
    Lai, Yingming
    Wang, Siqi
    Ozaki, Tsuneyuki
    Liang, Jinyang
    OPTICS EXPRESS, 2022, 30 (11) : 19824 - 19838
  • [39] Three-dimensional measurement of the local extinction coefficient in a dense spray
    Wellander, Rikard
    Berrocal, Edouard
    Kristensson, Elias
    Richter, Mattias
    Alden, Marcus
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (12)
  • [40] Three-dimensional microfabrication by laser-induced chemical deposition
    Liu, LB
    Li, MH
    Zhao, Y
    Yang, CX
    LASERS IN MATERIAL PROCESSING AND MANUFACTURING, 2002, 4915 : 278 - 284