Characterising an electron pencil beam: Monte Carlo vs measurement

被引:0
|
作者
Ebert, M [1 ]
Barnes, M [1 ]
机构
[1] Univ Newcastle, Newcastle, NSW 2308, Australia
关键词
D O I
10.1118/1.1998013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Electron beams from linear accelerators have widely varying characteristics in terms of spectral properties, mixtures of electrons and photons, spatial and angular characteristics. Characterizing pencil beams for pencil‐beam based calculations and for complex electron optimization calculations is thus necessary for individual electron beams. We evaluated an extrapolation method for characterizing an electron pencil beam and compared a Monte Carlo based method with measurement. Method and Materials: Radiographic film was used to measure narrow 12 MeV electron beams from a Varian 21EX accelerator. A series of circular beams was considered, collimated with LMPA material between diameters of 1.5 and 32 millimeters. Beam profiles were measured at discrete depths, and the presence of photon contamination from the LMPA was accounted for by subtracting measurements for a solid piece of LMPA. From these measurements, an extrapolation was made to estimate the distribution for a 0.1 mm diameter beam. A similar process was carried out using EGSnrc Monte Carlo, with electron beam characteristics determined using BEAM. Results: A large amount of similarity was found between pencil beam distributions extrapolated from film‐measured and Monte Carlo derived data. Given the amount of noise present in the measured and simulated results, the curve‐fitting procedure yielded relatively smooth and appropriate pencil beam distributions. It was also found that the parameters from the curve‐fitting could be used to extract central axis percentage depth dose distributions which were consistent (past dmax) with measured broad beam data. Conclusion: This study showed that the extrapolation method is appropriate for derivation of dose distributions for very narrow beams. A Monte Carlo simulated narrow beam distribution would normally be sufficient for characterizing such a distribution, though if high resolution is required, the extrapolation method would be useful. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2015 / 2016
页数:2
相关论文
共 50 条
  • [1] Comparison of Monte Carlo and pencil beam electron planning algorithms
    Perrett, T
    Gray, K
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S92 - S92
  • [2] An evaluation of Pencil Beam vs Monte Carlo calculations for intracranial stereotactic radiosurgery
    Rembish, Jacob
    Myers, Pamela
    Kirby, Neil
    Saenz, Daniel
    Rasmussen, Karl
    Papanikolaou, Nikos
    Stathakis, Sotirios
    JOURNAL OF BUON, 2020, 25 (06): : 2731 - 2736
  • [3] Comparison of Electron Monte Carlo and Pencil-Beam Algorithms in Clinical Electron Beam Radiation Dosimetry
    Liu, Z.
    Hargrove, I.
    Tazi, A.
    Barrett, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] USE OF MONTE-CARLO GENERATED PENCIL BEAM DATA IN ELECTRON DOSIMETRY
    RILEY, RJ
    MOHAN, R
    LAUGHLIN, JS
    GOODMAN, M
    KARPOVSKY, A
    GABRIEL, T
    MEDICAL PHYSICS, 1981, 8 (05) : 741 - 741
  • [5] Monte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
    Sikora, Marcin
    Muzik, Jan
    Soehn, Matthias
    Weinmann, Martin
    Alber, Markus
    RADIATION ONCOLOGY, 2009, 4
  • [6] Monte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
    Marcin Sikora
    Jan Muzik
    Matthias Söhn
    Martin Weinmann
    Markus Alber
    Radiation Oncology, 4
  • [7] Electron fields in clinical use - a comparison of the pencil beam method and Monte Carlo code
    Treutwein, M.
    Bogner, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 100 - 100
  • [8] USE OF MONTE-CARLO GENERATED PENCIL BEAM DATA FOR ELECTRON TREATMENT PLANNING
    RILEY, R
    MOHAN, R
    CHUI, C
    MEDICAL PHYSICS, 1985, 12 (04) : 516 - 516
  • [9] Effects of physics change in Monte Carlo code on electron pencil beam dose distributions
    Toutaoui, Abdelkader
    Khelassi-Toutaoui, Nadia
    Brahimi, Zakia
    Chami, Ahmed Chafik
    RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (01) : 1 - 8
  • [10] Electron fields in clinical application. A comparison of pencil beam and Monte Carlo algorithm
    Treutwein, Marius
    Bogner, Ludwig
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 (08) : 454 - 458