Best Practices of Aortic Valve Replacement With the Edwards Intuity Elite Valve

被引:8
作者
Malaisrie, S. Chris [1 ]
Mumtaz, Mubashir A. [2 ]
DiGiorgi, Paul L. [3 ]
Hoffberger, Jonathan D. [4 ]
Slachman, Frank N. [5 ]
Grosner, Gary [6 ]
Herskowitz, Kenneth [7 ]
Segurola, Romualdo J., Jr. [8 ]
Accola, Kevin D. [9 ]
Davies, James E. [10 ]
机构
[1] Northwestern Univ, Div Cardiac Surg, Northwestern Med, 201 E Huron St, Chicago, IL 60611 USA
[2] UPMC Pinnacle Hlth, Dept Cardiovasc & Thorac Surg, Harrisburg, PA USA
[3] Lee Mem Hlth Syst, Shipley Cardiothorac Ctr, Ft Myers, FL USA
[4] Sarasota Mem Hosp, Dept Cardiothorac Surg, Sarasota, FL USA
[5] Mercy Gen Hosp, Dept Surg, Dign Hlth, Sacramento, CA USA
[6] Gates Vasc Inst, Dept Cardiac Surg, Buffalo, NY USA
[7] Broward Hlth Med Ctr, Div Cardiac Surg, Ft Lauderdale, FL USA
[8] Jackson Mem Hosp, Jackson Heart Surg Inst, Dept Cardiac Surg, Doral, FL USA
[9] AdventHlth Orlando Cardiovasc Inst, Dept Thorac Cardiovasc Surg, Orlando, FL USA
[10] Univ Alabama Birmingham, Dept Surg, Birmingham, AL 35294 USA
关键词
RAPID DEPLOYMENT;
D O I
10.1016/j.athoracsur.2019.10.042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. The Edwards Intuity Elite (EIE; Edwards Lifesciences, Irvine, CA) valve system is a recent surgical aortic valve designed to expedite implantation, facilitate minimally invasive approaches, and provide low gradients, particularly in smaller valve sizes. The report reviews various best practices learned through experience with the EIE valve system. Description. With its sealing frame designed to anchor and seal the valve after resection of the diseased native aortic valve, EIE use differs from that of conventional sutured valves. Evaluation. Critical technical aspects include patient selection, aortotomy and debridement, valve sizing, guiding suture technique and valve seating and deployment. In addition, special anatomic and pathologic conditions are considered, as well as intraoperative transesophageal echocardiography and postimplantation cardiac rhythm monitoring. Conclusions. These best practices simplify and standardize the use of the EIE valve system and may benefit surgeons adopting this valve. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:1289 / 1293
页数:5
相关论文
共 11 条
[1]   Step-by-Step Aortic Valve Replacement With a New Rapid Deployment Valve [J].
Accola, Kevin D. ;
Chitwood, W. Randolph, Jr. ;
Mumtaz, Mubashir A. ;
Barnhart, Glenn R. .
ANNALS OF THORACIC SURGERY, 2018, 105 (03) :966-971
[2]   TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve [J].
Barnhart, Glenn R. ;
Accola, Kevin D. ;
Grossi, Eugene A. ;
Woo, Y. Joseph ;
Mumtaz, Mubashir A. ;
Sabik, Joseph F. ;
Slachman, Frank N. ;
Patel, Himanshu J. ;
Borger, Michael A. ;
Garrett, H. Edward, Jr. ;
Rodriguez, Evelio ;
McCarthy, Patrick M. ;
Ryan, William H. ;
Duhay, Francis G. ;
Mack, Michael J. ;
Chitwood, W. Randolph, Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (02) :241-+
[3]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA) [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Lluis ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Luis Zamorano, Jose ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hector ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Luis Tamargo, Juan ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Baensch, Dietmar ;
Baumgartner, Helmut .
EUROPEAN HEART JOURNAL, 2013, 34 (29) :2281-2329
[4]   Early and Mid-Term Results of Rapid Deployment Valves: The Intuity Italian Registry (INTU-ITA) [J].
D'Onofrio, Augusto ;
Tessari, Chiara ;
Filippini, Claudia ;
Bagozzi, Lorenzo ;
Diena, Marco ;
Alamanni, Francesco ;
Massetti, Massimo ;
Livi, Ugolino ;
Di Eusanio, Marco ;
Mignosa, Carmelo ;
Russo, Claudio ;
Rinaldi, Mauro ;
Di Bartolomeo, Roberto ;
Salvador, Loris ;
Antona, Carlo ;
Maselli, Daniele ;
De Paulis, Ruggero ;
Luzi, Giampaolo ;
Alfieri, Ottavio ;
De Filippo, Carlo Maria ;
Portoghese, Michele ;
Musumeci, Francesco ;
Bortolotti, Uberto ;
Gerosa, Gino ;
Rahmanian, Parwis B. .
ANNALS OF THORACIC SURGERY, 2018, 106 (06) :1742-1750
[5]   Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR): early results from 3343 patients [J].
Di Eusanio, Marco ;
Phan, Kevin ;
Berretta, Paolo ;
Carrel, Thierry P. ;
Andreas, Martin ;
Santarpino, Giuseppe ;
Di Bartolomeo, Roberto ;
Folliguet, Thierry ;
Meuris, Bart ;
Mignosa, Carmelo ;
Martinelli, Gianluca ;
Misfeld, Martin ;
Glauber, Mattia ;
Kappert, Utz ;
Shrestha, Malak ;
Albertini, Alberto ;
Teoh, Kevin ;
Villa, Emmanuel ;
Yan, Tristan ;
Solinas, Marco .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (04) :768-773
[6]   Rapid Deployment Versus Conventional Bioprosthetic Valve Replacement for Aortic Stenosis [J].
Ensminger, Stephan ;
Fujita, Buntaro ;
Bauer, Timm ;
Moellmann, Helge ;
Beckmann, Andreas ;
Bekeredjian, Raffi ;
Bleiziffer, Sabine ;
Landwehr, Sandra ;
Hamm, Christian W. ;
Mohr, Friedrich W. ;
Katus, Hugo A. ;
Harringer, Wolfgang ;
Walther, Thomas ;
Frerker, Christian .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (13) :1417-1428
[7]  
Glauber M, 2016, INNOVATIONS, V11, P165, DOI 10.1097/IMI.0000000000000287
[8]   Alternative Implantation Technique for Rapid Deployment Valve [J].
Kaku, Yuji ;
Segurola, Romualdo J. ;
Rego, Alfredo ;
McCarthy, Patrick M. ;
Malaisrie, S. Chris .
ANNALS OF THORACIC SURGERY, 2019, 107 (04) :E291-E292
[9]   Long-term outcomes of a rapid deployment aortic valve: data up to 5 years [J].
Laufer, Guenther ;
Haverich, Axel ;
Andreas, Martin ;
Mohr, Friedrich W. ;
Walther, Thomas ;
Shrestha, Malakh ;
Rahmanian, Parwis ;
Holzhey, David ;
Roth, Matthias ;
Schmitz, Christoph ;
Schramm, Rene ;
Giot, Christophe ;
Wahlers, Thorsten C. W. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (02) :281-287
[10]   Current era minimally invasive aortic valve replacement: Techniques and practice [J].
Malaisrie, S. Chris ;
Barnhart, Glenn R. ;
Farivar, R. Saeid ;
Mehall, John ;
Hummel, Brian ;
Rodriguez, Evelio ;
Anderson, Mark ;
Lewis, Clifton ;
Hargrove, Clark ;
Ailawadi, Gorav ;
Goldman, Scott ;
Khan, Junaid ;
Moront, Michael ;
Grossi, Eugene ;
Roselli, Eric E. ;
Agnihotri, Arvind ;
Mack, Michael J. ;
Smith, J. Michael ;
Thourani, Vinod H. ;
Duhay, Francis G. ;
Kocis, Mark T. ;
Ryan, William H. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (01) :6-14