The Effect of Blood Inflow and B1-Field Inhomogeneity on Measurement of the Arterial Input Function in Axial 3D Spoiled Gradient Echo Dynamic Contrast-Enhanced MRI

被引:53
作者
Roberts, Caleb [1 ,2 ]
Little, Ross [1 ,2 ]
Watson, Yvonne [1 ,2 ]
Zhao, Sha [1 ,2 ]
Buckley, David L. [1 ,3 ]
Parker, Geoff J. M. [1 ,2 ]
机构
[1] Univ Manchester, Sch Canc & Enabling Sci, Manchester M13 9PT, Lancs, England
[2] Univ Manchester, Univ Manchester Biomed Imaging Inst, Manchester M13 9PT, Lancs, England
[3] Univ Leeds, Div Med Phys, Leeds, W Yorkshire, England
关键词
arterial input function; dynamic contrast-enhanced MRI; blood inflow; tracer kinetic modeling; PHASE-I EVALUATION; PEGYLATED DI-FAB; RF PULSE-SHAPE; RADIOFREQUENCY FIELD; STEADY-STATE; T-1; ACCURATE; NONUNIFORMITY; TRANSMITTER; TUMORS;
D O I
10.1002/mrm.22593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A major potential confound in axial 3D dynamic contrast-enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this study was to use computer simulations, flow phantom, and in vivo studies to describe and understand the effect of blood inflow on the measurement of the arterial input function. All experiments were done at 1.5 T using a typical 3D dynamic contrast-enhanced magnetic resonance imaging sequence, and arterial input functions were extracted for each slice in the imaging volume. We simulated a set of arterial input functions based on the same imaging parameters and accounted for blood inflow and radiofrequency field inhomogeneities. Measured arterial input functions along the vessel length from both in vivo and the flow phantom agreed with simulated arterial input functions and show large overestimations in the arterial input function in the first 30 mm of the vessel, whereas arterial input functions measured more centrally achieve accurate contrast agent concentrations. Use of inflow-affected arterial input functions in tracer kinetic modeling shows potential errors of up to 80% in tissue microvascular parameters. These errors emphasize the importance of careful placement of the arterial input function definition location to avoid the effects of blood inflow. Magn Reson Med 65:108-119, 2011. (c) 2010 Wiley-Liss, Inc.
引用
收藏
页码:108 / 119
页数:12
相关论文
共 36 条
[1]   A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI [J].
Barker, GJ ;
Simmons, A ;
Arridge, SR ;
Tofts, PS .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :59-67
[2]   Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects [J].
Buckley, David L. ;
Shurrab, Ala'a E. ;
Cheung, Ching M. ;
Jones, Andrew P. ;
Mamtora, Hari ;
Kalra, Philip A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1117-1123
[3]  
BUCKLEY DL, 2004, P 12 ANN ISMRM KYOT
[4]   Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity [J].
Cheng, HLM ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :566-574
[5]   Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state [J].
Deoni, SCL ;
Rutt, BK ;
Peters, TM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :515-526
[6]   Measurement of the arterial concentration of Gd-DTPA using MRI: A step toward quantitative perfusion imaging [J].
FritzHansen, T ;
Rostrup, E ;
Larsson, HBW ;
Sondergaard, L ;
Ring, P ;
Henriksen, O .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :225-231
[7]   New algorithm for quantifying vascular changes in dynamic contrast-enhanced MRI independent of absolute T1 values [J].
Haacke, E. Mark ;
Filleti, Cristina L. ;
Gattu, Ramtilak ;
Ciulla, Carlo ;
Al-Bashir, Areen ;
Suryanarayanan, Krithivasan ;
Li, Meng ;
Latif, Zahid ;
DelProposto, Zach ;
Sehgal, Vivek ;
Li, Tao ;
Torquato, Vidya ;
Kanaparti, Rajesh ;
Jiang, Jing ;
Neelavalli, Jaladhar .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) :463-472
[8]   A fast 3D Look-Locker method for volumetric T1 mapping [J].
Henderson, E ;
McKinnon, G ;
Lee, TY ;
Rutt, BK .
MAGNETIC RESONANCE IMAGING, 1999, 17 (08) :1163-1171
[9]  
Jackson A., 2005, Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Oncology
[10]   Blockade of platelet-derived growth factor receptor-beta by CDP860, a humanized, PEGylated di-Fab', leads to fluid accumulation and is associated with increased tumor vascularized volume [J].
Jayson, GC ;
Parker, GJM ;
Mullamitha, S ;
Valle, JW ;
Saunders, M ;
Broughton, L ;
Lawrance, J ;
Carrington, B ;
Roberts, C ;
Issa, B ;
Buckley, DL ;
Cheung, S ;
Davies, K ;
Watson, Y ;
Zinkewich-Péotti, K ;
Rolfe, L ;
Jackson, A .
JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (05) :973-981