Analysis of OPD-Scan and Pentacam Parameters for Early Keratoconus Detection

被引:12
作者
Donoso, Rodrigo [1 ,2 ]
Rodriguez, Alvaro [1 ,2 ]
Esteffan, Karim [1 ,2 ]
Lagos, Claudio [3 ]
Aranguiz, Diego [2 ]
Hernandez, Nicolas [2 ]
机构
[1] Univ Chile, Fac Med, Dept Ophthalmol, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Clin Oftalmol Pasteur, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Dept Radiol, Santiago, Chile
关键词
OPTICAL COHERENCE TOMOGRAPHY; SUBCLINICAL KERATOCONUS; BIOMECHANICAL CHARACTERIZATION; CORNEAL TOPOGRAPHY; FELLOW EYES; PROGRESSION; THICKNESS; INDEXES; ECTASIA; ASYMMETRY;
D O I
10.1016/j.ajo.2021.01.012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND: PURPOSE: To evaluate Pentacam and OPD-Scan parameters in the early detection of keratoconus. DESIGN: Retrospective case-control study. METHODS: Case group included 50 clinically unaffected fellow eyes diagnosed with asymmetric keratoconus showing subtle qualitative changes at the 0.5-D sensitivity OPD-Scan scale, as well as normal anterior and back elevation difference map at Belin/Ambrosio enhanced ectasia display (BAD) at the Pentacam. Control group included 172 normal eyes that underwent Lasik surgery and presented no complications throughout the 2-year follow-up period. OPD-Scan and Pentacam parameters were compared, calculating sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). A multivariate analysis was performed using Pentacam or OPD-Scan variables, and a model using variables of both devices. RESULTS: Pentacam variables with AUC >0.8 were keratoconus index (0.85), index of height decentration (0.81), and overall deviation at BAD (0.8). OPD-Scan variables with AUC >0.8 were keratoconus prediction index (0.83), surface asymmetry index (0.83), and total of higher-order trefoil aberration (0.8). In the multivariate analysis, the AUC was 0.85 in the case of OPD-Scan whereas it was 0.89 in the case of Pentacam. When combining all variables from the 2 devices, the AUC was 0.93, with a sensitivity of 82% and a specificity of 94%. CONCLUSIONS: Several parameters of OPD-Scan and Pentacam can be useful to differentiate cases from nor-mal control eyes, demonstrating even better results when combining parameters of both devices. Anterior corneal indexes were the most important parameters to discriminate both groups. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 51 条
  • [21] Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography
    Li, Yan
    Chamberlain, Winston
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (02) : 284 - 295
  • [22] Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic Eyes
    Li, Yan
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    [J]. OPHTHALMOLOGY, 2012, 119 (12) : 2425 - 2433
  • [23] Detection of ectatic corneal diseases based on Pentacam
    Lopes, Bernardo T.
    Ramos, Isaac C.
    Dawson, Daniel G.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (02): : 136 - 142
  • [24] MAEDA N, 1994, INVEST OPHTH VIS SCI, V35, P2749
  • [25] IDENTIFYING PROGRESSION OF SUBCLINICAL KERATOCONUS BY SERIAL TOPOGRAPHY ANALYSIS
    MAGUIRE, LJ
    LOWRY, JC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 112 (01) : 41 - 45
  • [26] New perspectives on the detection and progression of keratoconus
    Martinez-Abad, Antonio
    Pinero, David P.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (09) : 1213 - 1227
  • [27] Motlagh Mahsaw N, 2019, Med Hypothesis Discov Innov Ophthalmol, V8, P177
  • [28] Comparison of multimetric D index with keratometric, pachymetric, and posterior elevation parameters in diagnosing subclinical keratoconus in fellow eyes of asymmetric keratoconus patients
    Muftuoglu, Orkun
    Ayar, Orhan
    Hurmeric, Volkan
    Orucoglu, Faik
    Kilic, Ilkay
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03) : 557 - 565
  • [29] Nidek Inc, 2011, TOK JAP OPD SCAN 3 O TOK JAP OPD SCAN 3 O
  • [30] The Genetics of Keratoconus
    Nowak, Dorota M.
    Gajecka, Marzena
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2011, 18 (01) : 2 - 6