On-line analysis of a continuous-flow ozonolysis reaction using Raman spectroscopy

被引:16
|
作者
Pelletier, M. J. [1 ]
Fabiilli, M. L. [1 ]
Moon, Brian [1 ]
机构
[1] Pfizer Global Res & Dev, Res Analyt, Pharmaceut Sci, Devlopmental API, Ann Arbor, MI 48105 USA
关键词
Raman; quantitative analysis; ozonolysis; trans-stilbene; benzaldehyde; alpha-methoxybenzyl hydroperoxide; spectral stripping; partial least squares; PLS;
D O I
10.1366/000370207782217725
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the use of an on-line Raman analyzer to quantitatively track the levels of trans-stilbene, benzaldehyde, and alpha-metboxybenzyl hydroperoxide in a continuous flow ozonolysis reactor. Quantitative analysis is carried out using spectral stripping in order to overcome baseline artifacts inherent in simple peak area determinations and to incorporate prior knowledge into the analytical model. The performance of spectral stripping is compared to partial least squares (PLS) analysis. The effect of two process variables, feed flow rate and ozone concentration, are also explored. Finally, the benefit of utilizing an on-line technique is illustrated by demonstrating the bias introduced by sampling for off-line analysis.
引用
收藏
页码:1107 / 1115
页数:9
相关论文
共 50 条
  • [41] C PHASE IN CONTINUOUS-FLOW ANALYSIS
    SPENCER, K
    DIXON, K
    NORTHAM, BE
    CLINICA CHIMICA ACTA, 1977, 77 (02) : 189 - 196
  • [42] CONTINUOUS-FLOW ANALYSIS OF CHOLESTEROL DIGITONIDE
    FRANZ, RL
    CLINICAL CHEMISTRY, 1978, 24 (04) : 725 - 726
  • [43] CONTINUOUS-FLOW AUTOMATED HPLC ANALYSIS
    KARGER, BL
    DOLAN, J
    GANT, JR
    GIESE, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 173 (MAR20): : 10 - 10
  • [44] IMMOBILIZED ENZYMES IN CONTINUOUS-FLOW ANALYSIS
    WERNER, M
    MOHRBACHER, RJ
    RIENDEAU, CJ
    MURADOR, E
    CAMBIAGHI, S
    CLINICAL CHEMISTRY, 1979, 25 (01) : 20 - 23
  • [45] Continuous-flow cytomorphological staining and analysis
    Tan, Andrew P.
    Dudani, Jaideep S.
    Arshi, Armin
    Lee, Robert J.
    Tse, Henry T. K.
    Gossett, Daniel R.
    Di Carlo, Dino
    LAB ON A CHIP, 2014, 14 (03) : 522 - 531
  • [46] Series DNA amplification using the continuous-flow polymerase chain reaction chip
    Joung, Seung-Ryong
    Kang, Chi Jung
    Kim, Yong-Sang
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (02) : 1342 - 1345
  • [47] Ethyl acetate synthesis on-line measurement by Raman spectroscopy
    Liu, DF
    Du, WM
    Zhou, HT
    Wang, JJ
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (03) : 301 - 303
  • [48] On-line prediction of antibody titer by Raman spectroscopy and chemometrics
    Andre, Silvere
    Saint Cristau, Lydia
    Gaillard, Sabine
    Devos, Olivier
    Calvosa, Eric
    Duponchel, Ludovic
    JOURNAL OF BIOTECHNOLOGY, 2015, 208 : S28 - S28
  • [49] A CONTINUOUS-FLOW SYSTEM FOR SENSITIVE URUSHIOL DETECTION USING A NEW CHEMILUMINESCENT REACTION
    ISHII, M
    TAKIMOTO, M
    MIYAKOSHI, T
    NAKAMURA, T
    ANALYTICAL SCIENCES, 1995, 11 (01) : 79 - 83
  • [50] On-line detection of electrophoretic separations on a microchip by Raman spectroscopy
    Reshni, KA
    Morris, MD
    Johnson, BN
    Burns, MA
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 109 - 112