On-line analysis of a continuous-flow ozonolysis reaction using Raman spectroscopy

被引:16
|
作者
Pelletier, M. J. [1 ]
Fabiilli, M. L. [1 ]
Moon, Brian [1 ]
机构
[1] Pfizer Global Res & Dev, Res Analyt, Pharmaceut Sci, Devlopmental API, Ann Arbor, MI 48105 USA
关键词
Raman; quantitative analysis; ozonolysis; trans-stilbene; benzaldehyde; alpha-methoxybenzyl hydroperoxide; spectral stripping; partial least squares; PLS;
D O I
10.1366/000370207782217725
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the use of an on-line Raman analyzer to quantitatively track the levels of trans-stilbene, benzaldehyde, and alpha-metboxybenzyl hydroperoxide in a continuous flow ozonolysis reactor. Quantitative analysis is carried out using spectral stripping in order to overcome baseline artifacts inherent in simple peak area determinations and to incorporate prior knowledge into the analytical model. The performance of spectral stripping is compared to partial least squares (PLS) analysis. The effect of two process variables, feed flow rate and ozone concentration, are also explored. Finally, the benefit of utilizing an on-line technique is illustrated by demonstrating the bias introduced by sampling for off-line analysis.
引用
收藏
页码:1107 / 1115
页数:9
相关论文
共 50 条
  • [31] Continuous flow and continuous publication: the challenges of on-line scientific
    da Silva, Eli Lopes
    Presser, Nadi Helena
    NAVUS-REVISTA DE GESTAO E TECNOLOGIA, 2019, 9 (03): : 5 - 6
  • [32] Membrane permeation continuous-flow isotope ratio mass spectrometry for on-line carbon isotope ratio determination
    Tremblay, Patrice
    Savard, Martine M.
    Smirnoff, Anna
    Paquin, Real
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (14) : 2213 - 2220
  • [33] On-line estimation of molecular orientation in polypropylene fibers using polarized Raman spectroscopy
    Paradkar, RP
    Sakhalkar, SS
    He, XJ
    Ellison, MS
    APPLIED SPECTROSCOPY, 2001, 55 (05) : 534 - 539
  • [34] Analysis of continuous-flow grain dryers
    BakkerArkema, FW
    Montross, MD
    Qiang, L
    Maier, DE
    GRAIN DRYING IN ASIA, 1996, (71): : 123 - 131
  • [35] HYDRODYNAMIC VOLTAMMETRY IN CONTINUOUS-FLOW ANALYSIS
    GUNASINGHAM, H
    FLEET, B
    ELECTROANALYTICAL CHEMISTRY, 1990, 16 : 89 - 180
  • [36] CONTINUOUS-FLOW ANALYSIS - PRESENT AND FUTURE
    SNYDER, LR
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 3 - 18
  • [37] CONTINUOUS-FLOW ANALYSIS OF SELECTED VITAMINS
    EGBERG, DC
    CEREAL FOODS WORLD, 1979, 24 (09) : 451 - 451
  • [38] INTERFACING OF HPLC WITH CONTINUOUS-FLOW ANALYSIS
    MACDONALD, JC
    AMERICAN LABORATORY, 1977, 9 (08) : 69 - &
  • [39] LAG FACTOR IN CONTINUOUS-FLOW ANALYSIS
    WALKER, WHC
    ANDREW, KR
    CLINICA CHIMICA ACTA, 1974, 57 (02) : 181 - 185
  • [40] INVESTIGATION OF TURBOMIXERS IN CONTINUOUS-FLOW ANALYSIS
    SPINKS, TL
    PACEY, GE
    FABIAN, L
    LEE, S
    BUBNIS, BP
    TALANTA, 1992, 39 (03) : 293 - 297