Analysis of the Flow Pattern and Flow Rectification Measures of the Side-Intake Forebay in a Multi-Unit Pumping Station

被引:23
|
作者
Nasr, Ahmed [1 ,2 ]
Yang, Fan [1 ,3 ]
Zhang, Yiqi [1 ]
Wang, Tieli [4 ]
Hassan, Mahmoud [5 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Yangzhou 225009, Jiangsu, Peoples R China
[2] Egyptian Minist Water Resources & Irrigat, Giza 12666, Egypt
[3] Minist Educ, Key Lab Fluid & Power Machinery, Chengdu 610039, Peoples R China
[4] Jiangsu Surveying & Design Inst Water Resources C, Yangzhou 225127, Jiangsu, Peoples R China
[5] Misr Univ Sci & Technol MUST, Fac Engn, Ind & Syst Engn Dept, Giza 12511, Egypt
基金
中国国家自然科学基金;
关键词
pumping station; forebay; flow pattern; numerical simulation; whirlpools; NUMERICAL-SIMULATION; OPTIMAL-DESIGN; WATER; CHANNEL; VORTEX; MODEL; BAY;
D O I
10.3390/w13152025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To improve the problem of turbulence in the forebay of the lateral inlet pumping station, a typical lateral inlet pumping station project in Xuzhou, Jiangsu Province, China was taken as the research object. The forebay of the pumping station is a building connecting the river channel and the pumping station into the water tank. Based on the Reynolds-averaged Navier-Stokes (RANS) law and the k-epsilon turbulence model, the computational fluid dynamics method (CFD) technology compares and analyzes the numerical simulation with or without rectification measures for the forebay of the lateral intake pumping station when multiple units are operating. The three-dimensional model was created by SolidWorks modeling software and the numerical simulation simulated by CFX-ANSYS. To alter the flow pattern in the forebay of the pumping station, various rectification measures were chosen. Internal rectification flow patterns in the forebay under multiple plans, uniformity of flow velocity distribution in the measuring section, and vortex area reduction rates are investigated and compared. Based on the analysis and comparison of numerical simulation results, when the parabolic wall and some rectification piers are set significantly it improves the flow pattern of the forebay of the lateral inlet pumping station. It also makes the flow pattern of the inlet pool better and increases the uniformity of the flow velocity distribution by 8%. Further, it reduced the vortex area by 70%, effectively improving the operating efficiency of the pump. The research results of this paper provide a technical reference for the improvement of the flow pattern in the forebay of the lateral inlet pumping station.
引用
收藏
页数:18
相关论文
共 10 条
  • [1] Numerical and Experimental Investigations of Flow Pattern and Anti-Vortex Measures of Forebay in a Multi-Unit Pumping Station
    Yang, Fan
    Zhang, Yiqi
    Liu, Chao
    Wang, Tieli
    Jiang, Dongjin
    Jin, Yan
    WATER, 2021, 13 (07)
  • [2] Improvement of the Flow Pattern of a Forebay with a Side-Intake Pumping Station by Diversion Piers Based on Orthogonal Test Method
    Zhang, Chen
    Yan, Haodi
    Jamil, Muhammad Tahir
    Yu, Yonghai
    WATER, 2022, 14 (17)
  • [3] NUMERICAL SIMULATION ON THE FLOW PATTERN IN FOREBAY OF PUMPING STATION
    Liu, Chao
    Lu, Meining
    PROCEEDINGS OF THE ASME 11TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2012, VOL 2, 2012, : 29 - 36
  • [4] Numerical Study on the Influence of Combined Rectification Facilities on the Flow in the Forebay of Pumping Station
    Zheng, Xiaobo
    Zhang, Pengli
    Zhang, Wenjing
    Yu, Yue
    Zhao, Yaping
    WATER, 2023, 15 (21)
  • [5] Influence of diffusion angle on flow field structure in forward intake forebay of pumping station
    Fan X.
    Dong C.
    Wang Z.
    Lu Y.
    Yao W.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2023, 39 (01): : 92 - 99
  • [6] Research on the measures of improve the flow pattern of the forebay of city intake water pumping stations
    Feng, Jiangang
    Li, Xin
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 1856 - 1861
  • [7] Analysis and Optimization of Flow Pattern in Inlet Passage of Pumping Station
    Bo, Yuan
    Feng, Wei-min
    Liu, Mei-qing
    Li, Qiu-wei
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 2485 - +
  • [8] Research on the influence of start-up combinations on the flow pattern in forebay of side-inlet pumping station on sandy river
    Xu C.
    Wang R.
    Liu H.
    Lian H.
    Wang Y.
    Wang G.
    Shuili Xuebao/Journal of Hydraulic Engineering, 2020, 51 (01): : 92 - 101
  • [9] Numerical analysis of pressure fluctuation characteristics of axial flow pump device of edge pump unit in multi-unit pumping station
    Li, Sihai
    Luan, Yi
    Xu, Yongbing
    Liu, Xizhu
    Yang, Fan
    Xu, Guiying
    AIP ADVANCES, 2024, 14 (07)
  • [10] Three-dimensional Numerical Analysis of Flow Pattern in Pressure Forebay of Hydropower Station
    Hou Caishui
    2012 INTERNATIONAL CONFERENCE ON MODERN HYDRAULIC ENGINEERING, 2012, 28 : 128 - 135