Experimental Analysis of Industry Standards on Derating of a Three-Phase Induction Motor due to Thermal Stress Caused by Voltage Unbalance

被引:0
作者
Springer, David [1 ]
Stolz, Erik [2 ]
Wiedenbrug, Ernesto [2 ]
机构
[1] Colorado State Univ, Ft Collins, CO 80523 USA
[2] Baker Instrument Comp, Ft Collins, CO 80523 USA
来源
2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6 | 2009年
关键词
Derating; Power Quality; Three-Phase Induction Motor; Unbalance; Voltage Unbalance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the results and analysis of an empirical verification of the NEMA standard MG-1 voltage unbalance derating graph using temperature sensors embedded in a 5 Hp motor. This verification process identifies a reference coil temperature and automatically regulates the load to maintain the reference temperature at the single hottest coil for a wide range of incoming voltage unbalances such that design lifespan is maintained. The experimental results are disparate with that of the NEMA MG-1 standard and display evidence that conditions of unbalance play a role in motor derating. An investigation between IEC and IEEE style unbalance calculations is presented with a clear indication that both styles represent the same physical system nearly identically.
引用
收藏
页码:1242 / +
页数:2
相关论文
共 6 条
[1]  
*EL APP SERV ASS E, PRINC LARG AC MOT
[2]  
*EL POW RES I E, 1992, EL MOT PRED PREV MAI
[3]  
*IEE, 2001, VOLT QUAL EL POW SYS
[4]  
*NAT EL MOT ASS, 2006, NEMA STAND
[5]   Derating of induction motors operating with a combination of unbalanced voltages and over or undervoltages [J].
Pillay, P ;
Hofmann, P ;
Manyage, M .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (04) :485-491
[6]  
Von Jouanne A., 2001, IEEE T POWER DELIVER