Acute and subacute ischemic stroke at high-field-strength (3.0-T) diffusion-weighted MR imaging: Intraindividual comparative study

被引:77
作者
Kuhl, CK [1 ]
Textor, J [1 ]
Gieseke, I [1 ]
von Falkenhausen, M [1 ]
Gernert, S [1 ]
Urbach, H [1 ]
Schild, HH [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
D O I
10.1148/radiol.2342031323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), image quality, and confidence in diagnosis between 1.5- and 3.0-T diffusion-weighted (DW) magnetic resonance (MR) imaging of ischemic stroke lesions. MATERIALS AND METHODS: The study design was approved by the institutional review board, and all patients gave informed consent. In a prospective intraindividual study, 25 patients who had clinical symptoms consistent with ischemic stroke underwent DW MR imaging at both 1.5 T and 3.0 T. The 3.0- or 1.5-T examination was performed immediately one after the other, in random order. Two. readers in consensus recorded the presence and number of ischemic lesions and rated image quality and lesion conspicuity. The image SNR and the CNR of the ischemic lesions were quantified. Paired Student t and Wilcoxon matched-pairs signed rank tests were used to test for statistical significance. RESULTS: Image quality at 3.0-T DW MR imaging was consistently lower than that at 1.5-T DW MR imaging owing to greater image distortions (P < .05). Yet, overall SNR and lesion CNR at 3.0 T increased,significantly; mean increases were 48.8% (P < .001) and 96.3% (P < .01), respectively. The higher overall SNR and lesion CNR t translated into a significantly higher sensitivity in the detection of ischemic lesions a 3.0 T than at 1.5 T. Of the total of 48 lesions that were identified in 19 of the 25 patients, 47 (98%) were diagnosed at 3.0 T and 36 (75%) were diagnosed at 1.5 T. In addition, the conspicuity of the lesions that were visible with both systems was significantly higher at 3.0 T (P < .001). CONCLUSION: Although 3.0-T DW MR imaging, generates greater image distortions, it yields increased SNR and CNR compared with DW MR imaging at 1.5 T. The increased CNR at 3.0 T translates into a significantly improved diagnostic confidence. in the detection of focal apparent diffusion coefficient changes in the setting of subacute and acute ischemic stroke. (C) RSNA, 2004.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 28 条
[1]   Differences in the diagnostic accuracy of acute stroke clinical subtypes defined by multimodal magnetic resonance imaging [J].
Allder, SJ ;
Moody, AR ;
Martel, AL ;
Morgan, PS ;
Delay, GS ;
Gladman, JR ;
Lennox, GG .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2003, 74 (07) :886-888
[2]   Diffusion tensor imaging using single-shot SENSE-EPI [J].
Bammer, R ;
Auer, M ;
Keeling, SL ;
Augustin, M ;
Stables, LA ;
Prokesch, RW ;
Stollberger, R ;
Moseley, ME ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :128-136
[3]   Clinical radiologic correlations in acute stroke: is the signal intensity at the end of the tunnel getting brighter quicker? [J].
Brown, DM ;
Levine, SR .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2003, 74 (07) :840-841
[4]   In vivo diffusion tensor imaging of rat spinal cord at 7 T [J].
Elshafiey, I ;
Bilgen, M ;
He, RJ ;
Narayana, PA .
MAGNETIC RESONANCE IMAGING, 2002, 20 (03) :243-247
[5]   Trend of stroke hospitalization, United States, 1988-1997 [J].
Fang, J ;
Alderman, MH .
STROKE, 2001, 32 (10) :2221-2225
[6]   Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging [J].
Forbes, KP ;
Pipe, JG ;
Karis, JP ;
Heiserman, JE .
RADIOLOGY, 2002, 225 (02) :551-555
[7]   Diffusion-weighted MR imaging:: Diagnostic accuracy in patients imaged within 6 hours of stroke symptom onset [J].
González, RG ;
Schaefer, PW ;
Buonanno, FS ;
Schwamm, LH ;
Budzik, RF ;
Rordorf, G ;
Wang, B ;
Sorensen, AG ;
Koroshetz, WJ .
RADIOLOGY, 1999, 210 (01) :155-162
[8]   Diffusion-tensor MR imaging at 1.5 and 3.0 T: Initial observations [J].
Hunsche, S ;
Moseley, ME ;
Stoeter, P ;
Hedehus, M .
RADIOLOGY, 2001, 221 (02) :550-556
[9]   Origin and minimization of residual motion-related artifacts in navigator-corrected segmented diffusion-weighted EPI of the human brain [J].
Jiang, HY ;
Golay, X ;
van Zijl, PCM ;
Mori, S .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :818-822
[10]  
Kidwell CS, 2000, ANN NEUROL, V47, P462, DOI 10.1002/1531-8249(200004)47:4<462::AID-ANA9>3.0.CO