共 35 条
Visualization of Vascular Compression of the Trigeminal Nerve With High-Resolution 3T MRI: A Prospective Study Comparing Preoperative Imaging Analysis to Surgical Findings in 40 Consecutive Patients Who Underwent Microvascular Decompression for Trigeminal Neuralgia
被引:112
作者:
Lacerda Leal, Paulo Roberto
[1
,4
]
Hermier, Marc
[2
]
Souza, Miguel Angelo
[3
]
Cristino-Filho, Gerardo
[4
]
Froment, Jean Claude
[2
]
Sindou, Marc
机构:
[1] Univ Lyon 1, Dept Neurosurg, Neurol Hosp Pierre Wertheimer, Grp Hosp Est, F-69003 Lyon, France
[2] Univ Lyon 1, Dept Neuroradiol, F-69003 Lyon, France
[3] Univ Fed Ceara, Fac Med Fortaleza, Dept Clin Med, Fortaleza, Ceara, Brazil
[4] Univ Fed Ceara, Fac Med Sobral, Dept Neurosurg, Sobral, Brazil
关键词:
Microvascular decompression;
MRI;
Neurovascular compression;
Three-dimensional imaging;
Trigeminal neuralgia;
PREDICTING NEUROVASCULAR COMPRESSION;
MAGNETIC-RESONANCE ANGIOGRAPHY;
PARTIAL SENSORY RHIZOTOMY;
LONG-TERM EFFECTIVENESS;
SERIES;
ACCURATE;
ANATOMY;
SITE;
PAIN;
D O I:
10.1227/NEU.0b013e318212bafa
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
BACKGROUND: High-resolution three-dimensional (3D) magnetic resonance imaging (MRI) has demonstrated its ability to predict fine trigeminal neurovascular anatomy. OBJECTIVE: To address the predictive value of 3-Tesla (3T) MRI in detecting and assessing features of neurovascular compression (NVC), particularly regarding the degree of compression exerted on the root, in patients who underwent microvascular decompression (MVD) for classic primary trigeminal neuralgia. METHODS: This prospective study includes 40 consecutive patients who underwent MVD for classic primary trigeminal neuralgia. All patients underwent a preoperative 3T MRI with 3D T2-weighted driven equilibrium (DRIVE), 3D time-of-flight (TOF) magnetic resonance angiography (MRA), and 3D T1-weighted gadolinium-enhanced sequences in combination. Evaluations were performed by 2 independent observers and compared with the operative findings. RESULTS: For prediction of NVC, image analysis corresponded with surgical findings in 39 cases. Of the 3 patients in whom image analysis did not show NVC, 2 did not have NVC at the time of intraoperative observation. MRI sensitivity was 97.4% (37/38), and specificity was 100% (2/2). The kappa coefficients (kappa) for predicting the offending vessel, its location, and the site of compression were 0.882, 0.813, and 0.942, respectively. Image analysis correctly defined the severity of the compression in 31 of the 37 cases. The kappa coefficients predicting the degree of compression were 0.813, 0.833, and 0.852, respectively, for Grades 1 (simple contact), 2 (distortion), and 3 (marked indentation). CONCLUSION: 3T MRI using 3D T2-weighted DRIVE in combination with 3D TOF-MRA and 3D T1-weighted gadolinium-enhanced sequences proved to be reliable in detecting NVC and in predicting the degree of root compression, the outcome being correlated with the latter.
引用
收藏
页码:15 / 25
页数:11
相关论文