Radiation levels and image quality in patients undergoing chest X-ray examinations

被引:2
作者
Campos de Oliveira, Paulo Marcio [1 ]
Santana, Priscila do Carmo [1 ]
de Sousa Lacerda, Marco Aurelio [2 ]
da Silva, Teogenes Augusto [2 ,3 ]
机构
[1] Fed Univ Minas Gerais UFMG, Anat & Image Dept, Av Prof Alfredo Balena 190, BR-30130100 Belo Horizonte, MG, Brazil
[2] Dev Ctr Nucl Technol CDTN CNEN, Av Presidente Antonio Carlos,6627 Campus UFMG, BR-31270901 Belo Horizonte, MG, Brazil
[3] Fed Univ Minas Gerais UFMG, Postgrad Program Nucl Sci & Tech, Av Presidente Antonio Carlos,6627,Campus UFMG, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Patient dosimetry; Image quality; X-ray chest examination; Radiation protection; DOSE MEASUREMENTS;
D O I
10.1016/j.radphyschem.2016.12.016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Patient dose monitoring for different radiographic procedures has been used as a parameter to evaluate the performance of radiology services; skin entrance absorbed dose values for each type of examination were internationally established and recommended aiming patient protection. In this work, a methodology for dose evaluation was applied to three diagnostic services: one with a conventional film and two with digital computerized radiography processing techniques. The x-ray beam parameters were selected and "doses" (specifically the entrance surface and incident air kerma) were evaluated based on images approved in European criteria during postero-interior (PA) and lateral (TAT) incidences. Data were collected from 200 patients related to 200 PA and 100 TAT incidences. Results showed that doses distributions in the three diagnostic services were very different; the best relation between dose and image quality was found in the institution with the chemical film processing. This work contributed for disseminating the radiation protection culture by emphasizing the need of a continuous dose reduction without losing the quality of the diagnostic image.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 19 条
[1]  
Azevedo Ana Cecília Pedrosa de, 2005, Radiol Bras, V38, P343, DOI 10.1590/S0100-39842005000500007
[2]  
Brazil, 1998, RADIOL PROT DIR MED
[3]  
Brazil, 2005, MED DIAGN RADIOL PER
[4]   Assessment of organ absorbed doses in patients undergoing chest X-ray examinations by Monte Carlo based softwares and phantom dosimetry [J].
Campos de Oliveira, Paulo Marcio ;
Squair, Peterson L. ;
Lacerda, Marco A. ;
da Silva, Teogenes A. .
RADIATION MEASUREMENTS, 2011, 46 (12) :2073-2076
[5]   First results on patient dose measurements from conventional diagnostic radiology procedures in Serbia and Montenegro [J].
Ciraj, O ;
Markovic, S ;
Kosutic, D .
RADIATION PROTECTION DOSIMETRY, 2005, 113 (03) :330-335
[6]   Assessment of dosimetric quantities for patients undergoing X-ray examinations in a large public hospital in Brazil-025EFa preliminary study [J].
de Sousa Lacerda, Marco Aurelio ;
da Silva, Teogenes Augusto ;
Khoury, Helen Jamil .
RADIATION PROTECTION DOSIMETRY, 2008, 132 (01) :73-79
[7]  
EU, 1996, 16260 EU EN
[8]   Dose measurements in chest diagnostic X rays: Adult and paediatric patients [J].
Freitas, MB ;
Yoshimura, EM .
RADIATION PROTECTION DOSIMETRY, 2004, 111 (01) :73-76
[9]  
IAEA, 2002, IAEA SER
[10]  
IAEA, 2011, 1667 IAEA TEC DOC