New method to determine the mass transfer resistance of sterile closures for shaken Bioreactors

被引:18
作者
Anderlei, Tibor [1 ]
Mrotzek, Christian [1 ]
Bartsch, Stefan [1 ]
Amoabediny, Ghassem [1 ]
Peter, Cyril P. [1 ]
Buechs, Jochen [1 ]
机构
[1] Univ Aachen, Rhein Westfal TH Aachen, D-52056 Aachen, Germany
关键词
aeration; mass transfer resistance; oxygen transfer rate; sterile closure; shake flask; water evaporation; relative humidity;
D O I
10.1002/bit.21490
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this paper a novel and easily applied method to measure the mass transfer resistance of the sterile closures (e.g. cotton plug) of shaken bioreactors is introduced. This method requires no investment in special equipment (e.g. an oxygen sensor) and can be performed with the materials usually available in typical laboratories. The method is based on the model of Henzler et al. (1986), which mechanistically describes mass transfer through the sterile closure of a shaken bioreactor based on diffusion coupled with Stefan convection. The concentration dependency of the multi-component diffusion coefficients is taken into account. The water loss from two equivalent shaken bioreactors equipped with sterile clo- sures during several days of shaking is measured. One flask contains distilled water, the other a saturated salt solution. From the water evaporation rate in each of the two flasks, the new model presented calculates the relative humidity in the environment, the average diffusion coefficient of oxygen in the sterile closure (D-O2), and the diffusion coefficient of carbon dioxide (D-CO2). The diffusion coefficient of carbon dioxide (D-CO2) only depends on the density and material properties of the sterile closure and not on the gas concentrations and is, therefore, an ideal parameter for the characterization of the mass transfer resistance. This new method is validated experimentally by comparing the diffusion coefficient of oxygen (D-O2) to a measurement by the classic dynamic method; and by comparing the calculated relative humidity in the environment to a humidity sensor measurement.
引用
收藏
页码:999 / 1007
页数:9
相关论文
共 25 条
[1]  
Aiba S, 1973, BIOCH ENG
[2]  
CHAIN EB, 1954, AERATION STUDIES, V17, P5
[3]   OXYGEN ABSORPTION RATES IN LABORATORY AND PILOT PLANT EQUIPMENT [J].
CORMAN, J ;
TSUCHIYA, HM ;
KOEPSELL, HJ ;
BENEDICT, RG ;
KELLEY, SE ;
FEGER, VH ;
DWORSCHACK, RG ;
JACKSON, RW .
APPLIED MICROBIOLOGY, 1957, 5 (05) :313-318
[4]  
DREW SW, 1981, LIQUID CULTURES METH
[5]   AGITATION-AERATION IN THE LABORATORY AND IN INDUSTRY [J].
FINN, RK .
BACTERIOLOGICAL REVIEWS, 1954, 18 (04) :254-274
[6]  
FLACH FA, 1963, BIOTECHNOL BIOENG, V5, P211
[7]  
Freedman D., 1969, PROCESS BIOCHEM, V2, P35
[8]   IMPROVED SHAKEN FLASK PERFORMANCE [J].
GADEN, EL .
BIOTECHNOLOGY AND BIOENGINEERING, 1962, 4 (01) :99-&
[9]   HUMIDITY FIXED-POINTS OF BINARY SATURATED AQUEOUS-SOLUTIONS [J].
GREENSPAN, L .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1977, 81 (01) :89-96
[10]   NON-EQUIMOLAR DIFFUSION IN SHAKING FLASKS - METHOD FOR DETERMINATION OF RESPIRATORY ACTIVITY OF BIOLOGICAL CULTURES [J].
HENZLER, HJ ;
SCHEDEL, M ;
MULLER, PF .
CHEMIE INGENIEUR TECHNIK, 1986, 58 (03) :234-235