Effects of External Field Orientation on Permanent Magnet Demagnetization

被引:18
作者
Peng, Peng [1 ]
Xiong, Han [1 ]
Zhang, Julia [1 ]
Li, Wanfeng [2 ]
Leonardi, Franco [2 ]
Rong, Chuanbing [2 ]
Degner, Michael W. [2 ]
Liang, Feng [2 ]
Zhu, Leyi [2 ]
机构
[1] Oregon State Univ, Corvallis, OR 97331 USA
[2] Ford Motor Co, Dearborn, MI 48121 USA
关键词
Demagnetizing magnetomotive force (MMF) orientation; demagnetization test; demagnetization test fixture; finite-element analysis (FEA); permanent magnet (PM); MACHINES;
D O I
10.1109/TIA.2017.2686344
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper investigates how the orientation of the applied demagnetizing magnetomotive force (MMF) affects the demagnetization behavior of Nd-Fe-B magnets that are widely used for permanent-magnet synchronous machines (PMSMs). This paper designs and builds a customized test fixture that can produce a magnetic field with varying orientation and intensity to demagnetize magnet samples. A computer-controlled 2-D mapping device is used to record the flux density above the test samples. The measurement results are compared with the 3-D finite-element analysis simulations. The understanding and insights obtained fromthis paperwill be used to improve the robustness ofmagnet design for high power density PMSMs with improved capability of withstanding demagnetization during overcurrent faults.
引用
收藏
页码:3438 / 3446
页数:9
相关论文
共 10 条
  • [1] CHOW LG, 1974, IEEE T MAGN, VMA10, P31, DOI 10.1109/TMAG.1974.1058296
  • [2] Demagnetization Analysis of Permanent Magnets According to Rotor Types of Interior Permanent Magnet Synchronous Motor
    Kim, Ki-Chan
    Kim, Kwangsoo
    Kim, Hee Jun
    Lee, Ju
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (06) : 2799 - 2802
  • [3] Partial Irreversible Demagnetization Assessment of Flux-Switching Permanent Magnet Machine Using Ferrite Permanent Magnet Material
    Li, Silong
    Li, Yingjie
    Sarlioglu, Bulent
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (07)
  • [4] Investigation of the Rotor Demagnetization Characteristics of Interior PM Synchronous Machines During Fault Conditions
    McFarland, James D.
    Jahns, Thomas M.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (04) : 2768 - 2775
  • [5] McFarland JD, 2013, IEEE ENER CONV, P4380, DOI 10.1109/ECCE.2013.6647286
  • [6] Post-Demagnetization Performance Assessment for Interior Permanent Magnet AC Machines
    Nair, Sreeju S.
    Patel, Vipulkumar I.
    Wang, Jiabin
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (04)
  • [7] Peng P., 2016, P IEEE C COMP VIS PA, P1
  • [8] Partial demagnetization of permanent magnets in electrical machines caused by an inclined field
    Ruoho, Sami
    Arkkio, Antero
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (07) : 1773 - 1778
  • [9] Permanent Magnet Demagnetization Process Considering the Inclination of the Demag Field
    Tizianel, S.
    Novello, N.
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (08)
  • [10] Permanent-Magnet Demagnetization Design and Validation
    Xiong, Han
    Zhang, Julia
    Degner, Michael W.
    Rong, Chuanbing
    Liang, Feng
    Li, Wanfeng
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (04) : 2961 - 2970