摘要
Ionophore-doped sensing membranes exhibit greater selectivities and wider measuring ranges if their membrane matrixes are noncoordinating and solvate interfering ions poorly. This is particularly true for fluorous phases, which are the least polar and polarizable condensed phases known. In this work, fluorous membrane matrixes were used to prepare silver ion-selective electrodes (ISEs). Sensing membranes composed of perfluoroperhydrophenanthrene, sodium tetrakis[3,5-bis(perfluorohexyl)phenyl]borate, and one of four fluorophilic Agtselective ionophores with one or two thioether groups were investigated. All electrodes exhibited Nernstian responses to Ag+ in a wide range of concentrations. Their selectivities for Ag+ over interfering ions were found to depend on host preorganizztion and the length of the -(CH2)- spacers separating the coordinating thioether group from the strongly electron withdrawing perfluoroalkyl groups. ISEs based on the most selective of the four ionophores, that is, 1,3-bis(perfluorodecylethylthiomethypbenzene, provided much higher selectivities for Ag+ over many alkaline and heavy metal ions than most Ag+ ISEs reported in the literature (e.g., log KZ for IC+, 11.6; Pb2(+), 10.2; Cu2+, 13.0; Cd2+, 13.2). Moreover, the use of this ionophore with a linear perfluorooligoether as membrane matrix and solid contacts consisting of three-dimensionally ordered macroporous (3DOM) carbon resulted in a detection limit for Ag+ of 4.1 ppt (3.8 x 1 0(-11) M).
引用
收藏
页码:7634 / 7640
页数:7
相关论文
共 56 条
  • [1] Silver(I) complexes of the derivatized crown thioether ligands 3,6,9,12,15,18-hexathianonadecanol and 3,6,9,13,16,19-hexathiaicosanol. Determination of stability constants and the crystal structures of [Ag(19-aneS6-OH)][CF3SO3] and [Ag(20-aneS6-OH)][BF4]
    Alberto, R
    Nef, W
    Smith, A
    Kaden, TA
    Neuburger, M
    Zehnder, M
    Frey, A
    Abram, U
    Schubiger, PA
    [J]. INORGANIC CHEMISTRY, 1996, 35 (11) : 3420 - 3427
  • [2] Syntheses of a series of S6 thioether cages and their coordination chemistry with Ag+
    Alberto, Roger
    Angst, Daniela
    Ortner, Kirstin
    Abram, Ulrich
    Schubiger, P. August
    Kaden, Thomas A.
    [J]. NEW JOURNAL OF CHEMISTRY, 2007, 31 (03) : 409 - 417
  • [3] Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores
    Amemiya, S
    Bühlmann, P
    Pretsch, E
    Rusterholz, B
    Umezawa, Y
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1618 - 1631
  • [4] [Anonymous], 1976, Pure and Applied Chemistry, V48, P127, DOI [10.1351/pac197648010127, DOI 10.1351/PAC197648010127]
  • [5] [Anonymous], 1991, FED REGISTER, V56, P3526
  • [6] *ASS OFF AN CHEM, 1990, OFF METH AN, P324
  • [7] Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes
    Bakker, E
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (06) : 1061 - 1069
  • [8] OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES
    BAKKER, E
    XU, AP
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1994, 295 (03) : 253 - 262
  • [9] Bakker E, 1999, ELECTROANAL, V11, P915, DOI 10.1002/(SICI)1521-4109(199909)11:13<915::AID-ELAN915>3.0.CO
  • [10] 2-J