Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver material

被引:27
作者
Matsuura, Yusuke [1 ]
Kuniyoshi, Kazuki [1 ]
Suzuki, Takane [2 ]
Ogawa, Yasufumi [1 ]
Sukegawa, Koji [1 ]
Rokkaku, Tomoyuki [3 ]
Takahashi, Kazuhisa [1 ]
机构
[1] Chiba Univ, Dept Orthoped Surg, Grad Sch Med, Chuo Ku, Chiba 2608670, Japan
[2] Chiba Univ, Dept Bioenvironm Med, Grad Sch Med, Chuo Ku, Chiba 2608670, Japan
[3] Chiba Aoba Municipal Hosp, Dept Orthoped Surg, Chuo Ku, Chiba 2600852, Japan
关键词
EXPERIMENTAL VALIDATION; MECHANICAL-PROPERTIES; CORTICAL BONE; PREDICTION; MODEL; BIOMECHANICS;
D O I
10.1007/s00776-014-0616-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Distal radius fracture, which often occurs in the setting of osteoporosis, can lead to permanent deformity and disability. Great effort has been directed toward developing noninvasive methods for evaluating the distal radius strength, with the goal of assessing fracture risk. The aim of this study was to evaluate distal radius strength using a finite element model and to gauge the accuracy of finite element model measurement using cadaver material. Ten wrists were obtained from cadavers with a mean age of 89.5 years at death. CT images of each wrist in an extended position were obtained. CT-based finite element models were prepared with Mechanical Finder software. Fracture on the models was simulated by applying a mechanical load to the palm in a direction parallel to the forearm axis, after which the fracture load and the site at which the fracture began were identified. For comparison, the wrists were fractured using a universal testing machine and the fracture load and the site of fracture were identified. The fracture load was 970.9 N in the finite element model group and 990.0 N in the actual measurement group. The site of the initial fracture was extra-articular to the distal radius in both groups. The finite element model was predictive for distal radius fracture when compared to the actual measurement. In this study, a finite element model for evaluation of distal radius strength was validated and can be used to predict fracture risk. We conclude that a finite element model is useful for the evaluation of distal radius strength. Knowing distal radius strength might avoid distal radius fracture because appropriate antiosteoporotic treatment can be initiated.
引用
收藏
页码:1012 / 1018
页数:7
相关论文
共 30 条
[1]   Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies [J].
Anderson, AE ;
Peters, CL ;
Tuttle, BD ;
Weiss, JA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03) :364-373
[2]   THE ELASTIC-MODULI OF HUMAN SUBCHONDRAL, TRABECULAR, AND CORTICAL BONE TISSUE AND THE SIZE-DEPENDENCY OF CORTICAL BONE MODULUS [J].
CHOI, K ;
KUHN, JL ;
CIARELLI, MJ ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1990, 23 (11) :1103-1113
[3]   Femoral strength is better predicted by finite element models than QCT and DXA [J].
Cody, DD ;
Gross, GJ ;
Hou, FJ ;
Spencer, HJ ;
Goldstein, SA ;
Fyhrie, DP .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1013-1020
[4]   Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography [J].
Crawford, RP ;
Cann, CE ;
Keaveny, TM .
BONE, 2003, 33 (04) :744-750
[5]   Bone strength: The whole is greater than the sum of its parts [J].
Davison, K. Shawn ;
Siminoski, Kerry ;
Adachi, J. D. ;
Hanley, David A. ;
Goltzman, David ;
Hodsman, Anthony B. ;
Josse, Robert ;
Kaiser, Stephanie ;
Olszynski, Wojciech P. ;
Papaioannou, Alexandra ;
Ste-Marie, Louis-George ;
Kendler, David L. ;
Tenenhouse, Alan ;
Brown, Jacques P. .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 2006, 36 (01) :22-31
[6]   Fall-related upper body injuries in the older adult: a review of the biomechanical issues [J].
DeGoede, KM ;
Ashton-Miller, JA ;
Schultz, AB .
JOURNAL OF BIOMECHANICS, 2003, 36 (07) :1043-1053
[7]   Finite element prediction of surface strain and fracture strength at the distal radius [J].
Edwards, W. Brent ;
Troy, Karen L. .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) :290-298
[8]   EFFECT OF BONE DISTRIBUTION ON VERTEBRAL STRENGTH - ASSESSMENT WITH PATIENT-SPECIFIC NONLINEAR FINITE-ELEMENT ANALYSIS [J].
FAULKNER, KG ;
CANN, CE ;
HASEGAWA, BH .
RADIOLOGY, 1991, 179 (03) :669-674
[9]   Experimental validation of a finite element model of a human cadaveric tibia [J].
Gray, Hans A. ;
Taddei, Fulvia ;
Zavatsky, Amy B. ;
Cristofolini, Luca ;
Gill, Harinderjit S. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (03)
[10]   Development and experimental validation of a three-dimensional finite element model of the human scapula [J].
Gupta, S ;
van der Helm, FCT ;
Sterk, JC ;
van Keulen, F ;
Kaptein, BL .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H2) :127-142