A study on the quantitative single and dual fault diagnosis of residential split type air conditioners in static operation using support vector machine method

被引:10
作者
Kim, Donghyuk [1 ]
Kang, Sukkyung [1 ]
Yoo, Jaisuk [1 ]
Kim, Dong-Kwon [1 ]
Youn, Baek [1 ]
机构
[1] Ajou Univ, Dept Mech Engn, Suwon 16499, Gyeonggi Do, South Korea
关键词
Air conditioner; Fault detection; Machine learning; Quantitative fault detection; Support vector machine; REFRIGERATION;
D O I
10.1016/j.ijrefrig.2021.07.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Owing to the recent uprise in summer temperatures, the use of air conditioners has been increasing accordingly. Air conditioners consume a significant amount of energy, and defects in air conditioners usually could lead to even more consumption of energy. Hence, early detection of defects could not only enhance user satisfaction, but also conserve energy. In the present work, quantitative fault detection models for single-and dual-failure modes have been developed using a support vector machine technique based on refrigeration cycle simulation data including normal and defective conditions. The defect modes investigated in the present work include refrigerant shortage and degraded air flow rates for the evaporator and condenser of an air conditioner. The results indicate that the proposed method can predict the values of more than 95% of the defective parameters within +/- 5% for the single-failure mode, and more than 90% of the data within +/- 10% for the dual-failure mode.
引用
收藏
页码:206 / 217
页数:12
相关论文
共 22 条
[1]   Optimal Fault Detection and Diagnosis in Transcriptional Circuits Using Next-Generation Sequencing [J].
Bahadorinejad, Arghavan ;
Braga-Neto, Ulisses M. .
IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2018, 15 (02) :516-525
[2]   PERFORMANCE DEGRADATION OF AN AIR-CONDITIONER CAUSED BY CYCLIC OPERATIONS [J].
BAHEL, V ;
BAKHSH, H ;
ZUBAIR, S .
ENERGY, 1988, 13 (02) :191-195
[3]   Support Vector Machines for classification and regression [J].
Brereton, Richard G. ;
Lloyd, Gavin R. .
ANALYST, 2010, 135 (02) :230-267
[4]   Fuzzy Algorithm for FDD Technique Development of System Multi-Air Conditioner [J].
Choi, C. S. ;
Tae, S. J. ;
Kim, H. M. ;
Cho, K. N. ;
Moon, J. M. ;
Kim, J. Y. ;
Kwon, H. J. .
TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2005, 29 (11) :1220-1228
[5]  
Elsayed Amr O., 2011, P WORLD REN EN C SWE, P2134
[6]   SYSTEM PERFORMANCE-CHARACTERISTICS OF AN AIR-CONDITIONER OVER A RANGE OF CHARGING CONDITIONS [J].
FARZAD, M ;
ONEAL, DL .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (06) :321-328
[7]  
Fischer S.K., 1983, ORNL/CON-80/RI
[8]  
HYLAND R, 1983, ASHRAE J, V25, P64
[9]  
HYLAND R, 1983, ASHRAE J, V25, P64
[10]  
Inatsu H., 1992, SAE TRANSACTIONS, V101, P165