共 50 条
Modeling and optimization of a commercial permeate gap spiral wound membrane distillation module for seawater desalination
被引:65
作者:
Ruiz-Aguirre, A.
[1
]
Andres-Manas, J. A.
[2
]
Fernandez-Sevilla, J. M.
[1
]
Zaragoza, G.
[2
]
机构:
[1] Univ Almeria, CIESOL, Ctra Sacramento S-N, La Canada De San Urbano 04120, Almeria, Spain
[2] CIEMAT Plataforma Solar Almeria, Ctra Senes S-N, Tabernas 04200, Almeria, Spain
来源:
关键词:
RESPONSE-SURFACE METHODOLOGY;
SOLAR DESALINATION;
MASS-TRANSFER;
WATER;
ENERGY;
HEAT;
EFFICIENCY;
SYSTEM;
PLANTS;
D O I:
10.1016/j.desal.2017.06.019
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
In this paper, a commercial spiral wound PGMD module was modeled and optimized for seawater desalination using Response Surface Methodology (RSM). Permeate flux (P-flux) and specific thermal energy consumption (STEC) were the main performance parameters to optimize, while evaporator inlet temperature (T-evap), condenser inlet temperature (T-cond) and feed flow rate (F) were the three operating parameters chosen. Analysis of variance (ANOVA) was used to evaluate statistically the response surface models. According to the study, T-evap, had the strongest effect on P-flux and STEC, increasing the former and decreasing the latter, F increased both responses, and T-cond had a weak effect on P-flux and practically none on STEC. The models were validated with further experimental data and a good correlation between experimental and predicted values of the responses was obtained for P-flux and STEC respectively. An optimization was performed to determine the operating conditions that produce a maximum value of P-flux and a minimum value of STEC simultaneously. The result of the multiple responses optimization using desirability function was a maximum Pflux of 2.661/h.m(2) and a minimum STEC of 255.8 kWh/m(3).
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条