Durable mechanical circulatory support in teenagers and adults with congenital heart disease: A systematic review

被引:23
作者
Steiner, Jill M. [1 ]
Krieger, Eric V. [1 ,2 ]
Stout, Karen K. [1 ]
Stempien-Otero, April [1 ]
Mahr, Claudius [1 ]
Mokadam, Nahush A. [3 ]
Hermsen, Joshua L. [3 ]
机构
[1] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[2] Seattle Childrens Hosp, Div Cardiol, Seattle, WA USA
[3] Univ Washington, Div Cardiothorac Surg, Seattle, WA 98195 USA
关键词
Mechanical circulatory support; Adult congenital; Heart failure; VENTRICULAR ASSIST DEVICE; TOTAL ARTIFICIAL-HEART; GREAT-ARTERIES; CORRECTED TRANSPOSITION; DEXTRO-TRANSPOSITION; PATIENT; TRANSPLANTATION; FAILURE; BRIDGE; IMPLANTATION;
D O I
10.1016/j.ijcard.2017.07.107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bac: kground: Heart failure is the leading cause of morbidity and mortality for adults with congenital heart disease (ACHD). Many patients are ineligible for transplantation, and those who are eligible often face long wait Limes with high wait-list morbidity. Durable mechanical circulatory support (MCS) may be an option for many patients. This systematic review evaluates the published literature on the use of durable MCS in teenagers and adults with congenital heart disease. Methods: A comprehensive search of MEDLINE (PubMed), EMBASE, and the Cochrane Library was performed electronically in July 2015 and updated in March 2016, guided by the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Results: Individual case reports and several case series identified 66 patients with ACHD treated with durable MCS. More than half were INTERMACS 1 or 2 at the time of implantation. Patients with Fontan repairs were more frequently classified as INTERMACS 1 or 2 (89% compared to 59%, Of less among other groups). Cases published after 2010 showed a trend toward less severe INTERMACS status, and patients were less likely to have received transplants by the time of reporting (31% compared to 61%, prior). Durable MCS was implanted as bridge-to-transplant in 77%. Patients with Fontan repair accounted for 14%, of cases. Conclusion: Reports of durable MCS utilization in patients with ACHD are becoming more frequent and devices are being implanted in more stable patients. Reports are mostly case reports or small case series so reporting bias is likely and prospective protocolecl reporting is needed. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
[21]   Seventh INTERMACS annual report: 15,000 patients and counting [J].
Kirklin, James K. ;
Naftel, David C. ;
Pagani, Francis D. ;
Kormos, Robert L. ;
Stevenson, Lynne W. ;
Blume, Elizabeth D. ;
Myers, Susan L. ;
Miller, Marissa A. ;
Baldwin, J. Timothy ;
Young, James B. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) :1495-1504
[22]   Ventricular Assist Device Implantation Late After Double Switch Operation for L-Transposition of the Great Arteries [J].
Komagamine, Masahide ;
Nishinaka, Tomohiro ;
Ichihara, Yuki ;
Nagashima, Mitsugi ;
Shimizu, Mikiko ;
Shinohara, Tokuko ;
Nakanishi, Toshio ;
Yamazaki, Kenji .
ANNALS OF THORACIC SURGERY, 2014, 98 (05) :E109-E111
[23]   Heart failure treatment in adults with congenital heart disease: where do we stand in 2014? [J].
Krieger, Eric V. ;
Valente, Anne Marie .
HEART, 2014, 100 (17) :1329-1334
[24]   Bridge to transplantation with long-term mechanical assist device in adults after the Mustard procedure [J].
Maly, Jiri ;
Netuka, Ivan ;
Besik, Josef ;
Dorazilova, Zora ;
Pirk, Jan ;
Szarszoi, Ondrej .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (09) :1177-1181
[25]   Heart transplantation with or without prior mechanical circulatory support in adults with congenital heart disease [J].
Maxwell, Bryan G. ;
Wong, Jim K. ;
Sheikh, Ahmad Y. ;
Lee, Peter H. U. ;
Lobato, Robert L. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (05) :842-846
[26]  
MEHTA SM, 1995, J HEART LUNG TRANSPL, V14, P585
[27]   Initial Experience of Left Ventricular Assist Device Support for Adult Patients with Transposition of the Great Vessels [J].
Menachem, Jonathan N. ;
Swaminathan, Aparna C. ;
Bashore, Thomas M. ;
Ward, Cary C. ;
Rogers, Joseph G. ;
Milano, Carmelo A. ;
Patel, Chetan B. .
CONGENITAL HEART DISEASE, 2015, 10 (05) :382-386
[28]  
Moher D, 2015, SYST REV-LONDON, V4, DOI [10.1186/2046-4053-4-1, 10.1136/bmj.i4086, 10.1016/j.ijsu.2010.07.299, 10.1371/journal.pmed.1000097, 10.1136/bmj.b2700, 10.1136/bmj.b2535, 10.1016/j.ijsu.2010.02.007]
[29]   Ventricular assist device outflow graft in congenitally corrected transposition of great arteries - a surgical challenge [J].
Mohite, Prashant N. ;
Popov, Aron F. ;
Garcia, Diana ;
Hards, Rachel ;
Zych, Bartlomeij ;
Khaghani, Asghar ;
Simon, Andre R. .
JOURNAL OF CARDIOTHORACIC SURGERY, 2012, 7
[30]   A new era: Use of an intracorporeal systemic ventricular assist device to support a patient with a failing Fontan circulation [J].
Morales, David L. S. ;
Adachi, Iki ;
Heinle, Jeffrey S. ;
Fraser, Charles D., Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (03) :E138-E140