Permanent left atrial pacing: A 2-year follow-up of coronary sinus leads

被引:2
|
作者
Mirza, I
James, S
Holt, P
机构
[1] John Radcliffe Hosp, Dept Cardiol, Oxford OX3 9DU, England
[2] Maidstone Gen Hosp, Maidstone, Kent, England
[3] Guys & St Thomas Hosp, London SE1 9RT, England
来源
关键词
coronary sinus; biatrial pacing; a trial fibrillation;
D O I
10.1111/j.1540-8159.2004.00434.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left atrial pacing is feasible via the coronary sinus. However, long-term characteristics of coronary sinus pacing parameters are largely undefined as yet. This study assessed the feasibility and long-term pacing parameters of coronary sinus pacing. Twenty four patients (13 men, 11 women) with a history of paroxysmal AF refractory to drug therapy underwent biatrial pacemaker implantation. Leads were sited in the high right atrium or right atrial appendage and in either proximal (PCS) or distal coronary sinus (DCS). Pacemaker parameters were measured at implant, 24 hours postimplunt, 1 month, 3 months, and at 3 monthly intervals over a period of 2 years. Threshold, impedance, and energy requirements (E = Threshold(2)/impedonce x pulse width) were measured. There was one lead displacement from the PCS within 24 hours postimplant. There were no other acute or chronic complications. The energy values at implant and at 2 years were 0.49 +/- 0.47 and 2.18 +/- 1.69 mJ for the PCS leads and 0.94 +/- 1.47 and 1.27 +/- 0.75 mJ for the DCS leads. P values were > 0.05 at all points and suggested no significant difference between the two sites over the long-term. Chronic coronary sinus pacing is a safe and feasible technique. There was no significant difference in energy parameters for leads positioned in the proximal or distal coronary sites. The trends seen at both sites for chronic changes in pacing characteristics are analogous to those described for endocardial leads at other sites.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 50 条
  • [21] Allogeneic parathyroid: 2-year follow-up
    Manuel Hermosillo-Sandoval, Jose
    Lisseth Leonher-Ruezga, Karla
    Alfredo Jimenez-Gomez, Jose
    Fuentes-Orozco, Clotilde
    Gonzalez-Ojeda, Alejandro
    Ricardo Ramirez-Gonzalez, Luis
    CIRUGIA Y CIRUJANOS, 2015, 83 (03): : 188 - 192
  • [22] SMR - 2-YEAR FOLLOW-UP SURVEY
    THOMAS, JN
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1978, 92 (08): : 661 - 666
  • [23] BRIEF HOSPITALIZATION - 2-YEAR FOLLOW-UP
    HERZ, MI
    ENDICOTT, J
    SPITZER, RL
    AMERICAN JOURNAL OF PSYCHIATRY, 1977, 134 (05): : 502 - 507
  • [24] BRIEF HOSPITALIZATION - 2-YEAR FOLLOW-UP
    HERZ, MI
    ENDICOTT, J
    GIBBON, M
    ARCHIVES OF GENERAL PSYCHIATRY, 1979, 36 (06) : 701 - 705
  • [25] 2-YEAR FOLLOW-UP OF HYPERACTIVE PRESCHOOLERS
    CAMPBELL, SB
    SCHLEIFER, M
    WEISS, G
    PERLMAN, T
    AMERICAN JOURNAL OF ORTHOPSYCHIATRY, 1977, 47 (01) : 149 - 162
  • [26] Permanent coronary sinus pacing - UP and BP pacing/sensing is not the same
    Kutarski, A
    Poleszak, K
    Koziara, D
    Oleszczak, K
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 411 - 415
  • [27] REHABILITATION OF IMPAIRED PHYSICIANS - 1-YEAR FOLLOW-UP AND 2-YEAR FOLLOW-UP
    HERRINGTON, RE
    BENZER, DG
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1981, 5 (01) : 153 - 153
  • [28] TRANSVENOUS, TRANSMEDIASTINAL, AND TRANSTHORACIC VENTRICULAR PACING - COMPARISON AFTER COMPLETE 2-YEAR FOLLOW-UP
    BRENNER, AS
    ANDERSON, ST
    ROSATI, RA
    MORRIS, JJ
    WAGNER, GS
    CIRCULATION, 1974, 49 (03) : 407 - 414
  • [29] Transfemoral paediatric permanent pacing. 20-year follow-up
    Costa, R
    Martinelli, M
    Nishioka, SAD
    Tamaki, WT
    Crevelari, ES
    Moreira, LFP
    Oliveira, SA
    EUROPEAN HEART JOURNAL, 2001, 22 : 237 - 237
  • [30] Cardiac Resynchronization Therapy in Patients with Atrial Fibrillation: A 2-Year Follow-Up Study
    Eisen, Alon
    Nevzorov, Roman
    Goldenberg, Gustavo
    Kuznitz, Haim
    Porter, Avital
    Golovtziner, Gregory
    Strasberg, Boris
    Haim, Moti
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (07): : 872 - 877