Permanent left atrial pacing: A 2-year follow-up of coronary sinus leads

被引:2
|
作者
Mirza, I
James, S
Holt, P
机构
[1] John Radcliffe Hosp, Dept Cardiol, Oxford OX3 9DU, England
[2] Maidstone Gen Hosp, Maidstone, Kent, England
[3] Guys & St Thomas Hosp, London SE1 9RT, England
来源
关键词
coronary sinus; biatrial pacing; a trial fibrillation;
D O I
10.1111/j.1540-8159.2004.00434.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left atrial pacing is feasible via the coronary sinus. However, long-term characteristics of coronary sinus pacing parameters are largely undefined as yet. This study assessed the feasibility and long-term pacing parameters of coronary sinus pacing. Twenty four patients (13 men, 11 women) with a history of paroxysmal AF refractory to drug therapy underwent biatrial pacemaker implantation. Leads were sited in the high right atrium or right atrial appendage and in either proximal (PCS) or distal coronary sinus (DCS). Pacemaker parameters were measured at implant, 24 hours postimplunt, 1 month, 3 months, and at 3 monthly intervals over a period of 2 years. Threshold, impedance, and energy requirements (E = Threshold(2)/impedonce x pulse width) were measured. There was one lead displacement from the PCS within 24 hours postimplant. There were no other acute or chronic complications. The energy values at implant and at 2 years were 0.49 +/- 0.47 and 2.18 +/- 1.69 mJ for the PCS leads and 0.94 +/- 1.47 and 1.27 +/- 0.75 mJ for the DCS leads. P values were > 0.05 at all points and suggested no significant difference between the two sites over the long-term. Chronic coronary sinus pacing is a safe and feasible technique. There was no significant difference in energy parameters for leads positioned in the proximal or distal coronary sites. The trends seen at both sites for chronic changes in pacing characteristics are analogous to those described for endocardial leads at other sites.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 50 条
  • [1] Safety and efficacy of Coronary Sinus Reducer implantation at 2-year follow-up
    Ponticelli, Francesco
    Tzanis, Giorgos
    Gallone, Guglielmo
    Baldetti, Luca
    Mangieri, Antonio
    Colombo, Antonio
    Giannini, Francesco
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 292 : 87 - 90
  • [2] CORONARY SINUS PACING - CLINICAL FOLLOW-UP
    GREENBERG, P
    CASTELLANET, M
    MESSENGER, J
    ELLESTAD, MH
    CIRCULATION, 1978, 57 (01) : 98 - 103
  • [4] Permanent left atrial pacing with a specifically designed coronary sinus lead
    Daubert, C
    Leclercq, C
    LeBreton, H
    Gras, D
    Pavin, D
    Pouvreau, Y
    VanVerooij, P
    Bakels, N
    Mabo, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (11): : 2755 - 2764
  • [5] SINUS NODE DYSFUNCTION TREATED OR NOT BY PACEMAKER - 2-YEAR FOLLOW-UP
    MEDVEDOWSKY, JL
    BARNAY, C
    MEDVEDOWSKY, A
    COSTE, A
    JOUVEN, JC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A49 - A49
  • [6] LONG-TERM FOLLOW UP OF PERMANENT PERVENOUS ATRIAL-PACING (PPAP) FROM CORONARY SINUS
    RIVERS, R
    MOSS, AJ
    KRAMER, D
    CIRCULATION, 1972, 46 (04) : 108 - &
  • [7] RESULTS OF LONG-TERM FOLLOW-UP OF PERMANENT ATRIAL-PACING IN PATIENTS WITH SICK SINUS SYNDROME
    KOLK, R
    LAANE, P
    ROOSE, I
    SAMARUTEL, J
    KARDIOLOGIYA, 1994, 34 (7-8) : 5 - 7
  • [8] Inflammatory markers in a 2-year follow-up of coronary artery disease
    Mizia-Stec, Katarzyna
    Gasior, Zbigniew
    Zahorska-Markiewiez, Barbara
    Holecki, Michat
    Kumor, Pawel
    HEART AND VESSELS, 2006, 21 (05) : 302 - 308
  • [9] Inflammatory markers in a 2-year follow-up of coronary artery disease
    Katarzyna Mizia-Stec
    Zbigniew Gąsior
    Barbara Zahorska-Markiewicz
    Michalł Holecki
    Pawelł Kumor
    Heart and Vessels, 2006, 21 : 302 - 308
  • [10] PERMANENT PERVENOUS ATRIAL-PACING FROM CORONARY VEIN - LONG-TERM FOLLOW-UP
    MOSS, AJ
    RIVERS, RJ
    KRAMER, DH
    CIRCULATION, 1974, 49 (02) : 222 - 225