Ultrasound imaging in women's arm flexor muscles: intra-rater reliability of muscle thickness and echo intensity

被引:10
作者
Vieira, Amilton [1 ]
Siqueira, Angelina F. [1 ]
Ferreira-Junior, Joao B. [1 ]
Pereira, Paulo [1 ]
Wagner, Dale [2 ]
Bottaro, Martim [1 ]
机构
[1] Univ Brasilia UnB, Fac Educ Fis, Lab Treinamento Forca, Brasilia, DF, Brazil
[2] Utah State Univ USU, Hlth Phys Educ & Recreat Dept HPER, Logan, UT USA
关键词
ultrasonography; rehabilitation; muscle hypertrophy; greyscale analysis; biceps brachii; elbow; TEST-RETEST RELIABILITY; SKELETAL-MUSCLE; SIZE; STRENGTH; VOLUME; YOUNG; ULTRASONOGRAPHY; EXERCISE; QUALITY; SESSION;
D O I
10.1590/bjpt-rbf.2014.0186
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Different ultrasound parameters have been frequently used to assess changes associated with training, aging, immobilization, and neuromuscular diseases. However, an exploratory reliability analysis of the echo intensity (EI) and muscle thickness (MT) of the forearm flexors is scarce, especially in women. Objective: The purpose of the present study was to determine the intra-rater reliability of MT and EI assessed by ultrasound in young women. Method: Ultrasonographic MT and EI were acquired in the forearm flexors of 41 young women (22 +/- 2 yrs). Reliability was calculated using intraclass correlation coefficient (ICC2,1), standard error of measurement (SEM), coefficient of variation (CV), smallest detectable change (SDC), and Bland and Altman plot analysis. Results: ICC values for MT and EI were 0.88 (95% CI: 0.78-0.93). The SEM and CV values were lower than 10%. Bland and Altman analysis revealed that ultrasound mean differences were 0.27 mm (Limits of Agreement -LOA 95%: -2.6 to 3.2 mm) and -0.09 a.u. (LOA 95%: - 10.9 to 10.7 a.u.). Conclusion: MT and EI assessed by ultrasonography in young women appear to be reliable and may be used to monitor changes in muscle mass induced by strength training when these changes exceed the precision of ultrasound.
引用
收藏
页码:535 / 542
页数:8
相关论文
共 33 条
[31]  
2-E
[32]   Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM [J].
Weir, JP .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2005, 19 (01) :231-240
[33]   Rehabilitative ultrasound imaging of pelvic floor muscle function [J].
Whittaker, Jackie L. ;
Thompson, Judith A. ;
Teyhen, Deydre S. ;
Hodges, Paul .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2007, 37 (08) :487-498