Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis

被引:321
|
作者
Kim, WY [1 ]
Han, CH [1 ]
Park, JI [1 ]
Kim, JY [1 ]
机构
[1] Catholic Univ Korea, Dept Orthopaed Surg, Daejon St Marys Hosp, Jung Gu, Taejon 301010, South Korea
关键词
D O I
10.1007/s002640100287
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have reviewed 178 intertrochanteric fractures treated by dynamic hip screw (DHS) fixation between March 1995 and December 1999 and followed for a minimum of 1 year. We used Singh's classification of the trabecular bone structure in the proximal femur as a measure of osteoporosis and also classified the fractures according to three different systems (Boyd-Griffin, Evans, AO). The postoperative radiographs were examined for loss of reduction, i.e. varus angulation >100, perforation of the femoral head, more than 20-mm extrusion of a lag screw or metal failure. We found 49 cases which showed radiographic failures. Two were stable fractures and 47 unstable fractures (Evans' classification). Unstable fractures with osteoporosis had a failure rate of more than 50%. In such cases DHS should not be the first choice for treatment.
引用
收藏
页码:360 / 362
页数:3
相关论文
共 50 条
  • [1] Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis
    Weon-Yoo Kim
    Chang-Hwan Han
    Jin-Il Park
    Jin-Young Kim
    International Orthopaedics, 2001, 25 : 360 - 362
  • [2] Screw fracture after sliding hip screw fixation of an intertrochanteric fracture
    Manicom, O.
    Karoubi, M.
    Mseddi, M.
    Demoura, A.
    Hernigou, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (06): : 602 - 605
  • [3] Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
    Emami, Mohamad
    Manafi, Alireza
    Hashemi, Behrooz
    Nemati, Ali
    Safari, Saeed
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2013, 1 (01): : 14 - 17
  • [4] Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture
    Wu, Hsu-Fu
    Chang, Chih-Han
    Wang, Gwo-Jaw
    Lai, Kuo-An
    Chen, Chung-Hwan
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (1)
  • [5] Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture
    Hsu-Fu Wu
    Chih-Han Chang
    Gwo-Jaw Wang
    Kuo-An Lai
    Chung-Hwan Chen
    BioMedical Engineering OnLine, 18
  • [6] Intertrochanteric fracture fixation with Dynamic Hip Screw: Is tip-apex distance measurement useful for predicting fixation failure?
    Goh, K. L.
    Zamzuri, Z.
    Ariff, Mohd S.
    Azril, Mohamed M. A.
    INTERNATIONAL MEDICAL JOURNAL MALAYSIA, 2016, 15 (01) : 31 - 34
  • [7] Functional and Radiological Outcome of Unstable Intertrochanteric Fracture Post Dynamic Hip Screw Fixation
    Lakho, Muhammad T.
    Jatoi, Asif A.
    Azfar, Muhammad Khanzada
    Ali, Aijaz
    Javed, Safiya
    Bhatti, Anisuddin
    Karim, Musa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [8] Iatrogenic Injury to Profunda Femoris During a Dynamic Hip Screw Fixation for Intertrochanteric Fracture
    Lal, Anuj
    Jesudason, Edwin
    Gwyn, Rhodri
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [9] Total hip arthroplasty for intertrochanteric fracture fixation failure
    Liyun Liu
    Yongqiang Sun
    Linlin Wang
    Qiankun Gao
    Ang Li
    Jialin Wang
    Yanzheng Gao
    European Journal of Medical Research, 24
  • [10] Total hip arthroplasty for intertrochanteric fracture fixation failure
    Liu, Liyun
    Sun, Yongqiang
    Wang, Linlin
    Gao, Qiankun
    Li, Ang
    Wang, Jialin
    Gao, Yanzheng
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2019, 24 (01)