OUTCOME OF CONSERVATIVE MANAGEMENT OF SPIRAL/LONG OBLIQUE FRACTURES OF THE METACARPAL SHAFT OF THE FINGERS USING A PALMAR WRIST SPLINT AND IMMEDIATE MOBILISATION OF THE FINGERS

被引:28
作者
Al-Qattan, M. M. [1 ]
机构
[1] King Saud Univ, Coll Med, Dept Surg, Riyadh 11461, Saudi Arabia
关键词
D O I
10.1177/1753193408093559
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Conservative management of spiral/long oblique fractures of the shaft of the metacarpal almost always results in shortening and hence these fractures have the reputation of ending up with an extension lag and reduced grip strength. In a prospective study, 42 patients with 54 fractures were treated with a palmar wrist splint and immediate mobilisation of all finger joints. All fractures united. Extension lag of fractured fingers was initially seen in all fingers, but eventually recovered. Grip strength progressively increased to reach a mean of 94% of the contralateral hand by 1 year after injury.