Assessment of fetal optic chiasm: an echoanatomic and reproducibility study

被引:13
|
作者
Paladini, D. [1 ]
Birnbaum, R. [1 ]
Donarini, G. [1 ]
Maffeo, I. [1 ]
Fulcheri, E. [2 ]
机构
[1] Ist Giannina Gaslini, Fetal Med & Surg Unit, Via Gerolamo Gaslini, I-16147 Genoa, Italy
[2] Ist Giannina Gaslini, Fetopathol Unit, Genoa, Italy
关键词
3D; fetus; optic chiasm; septo-optic dysplasia; ultrasound; SEPTUM PELLUCIDUM; DYSPLASIA; DIAGNOSIS; FETUSES;
D O I
10.1002/uog.17227
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives Our aims were: (1) to perform an echoanatomic correlation study, in order to confirm that the structure identified as the optic chiasm (OC) on ultrasound (US) is indeed this anatomical structure; (2) to assess and compare the reproducibility of two(2D) and three-(3D) dimensional US in measurement of the OC in normal fetuses; and (3) to assess whether the spatial orientation of the OC changes with increasing gestational age. Methods For the echoanatomic study, the OC was studied in a neonatal specimen, deceased at 29+4 weeks, by passing a suture around the OC and visualizing the supposed OC structure on US while pulling gently on the suture. The reproducibility study included 39 women with normal pregnancy at 20-33 weeks undergoing routine obstetric US examination. After the routine exam, the OC was visualized on 2D-US, and a 2D image and 3D volume dataset were stored for offline measurement. On the 2D images, the diameters of the OC decussation and the optic tract proximal to the transducer were measured. For the 3D volume dataset, multiplanar image correlation with volume contrast imaging (VCI) was used to measure both these diameters and the chiasmocallosal angle (CCA). Two operators each took two sets of measurements of the diameters on 2D- and 3D-US, and intra-and interoperator variability were analyzed using Cronbach's alpha intraclass correlation coefficient (ICC), while a single operator took two sets of CCA measurements for assessment of intraoperator variability. Differences in CCA with increasing gestational age were also analyzed by regression, and CCA measurements were divided into three groups according to gestational age and their means compared by one-way ANOVA. Results During the echoanatomic experiment, when the sling suture was pulled, the hyperechoic X-shaped structure just below the circle of Willis identified on 2D-US as the OC was displaced slightly and was eventually cut by the sling, confirming its identity as the OC. Intraoperator variability was low and almost identical for the two operators and the two imaging modalities for measurement of the decussation (ICC for 2D-US: 0.96 vs 0.95; 3D-US: 0.95 vs 0.96), but less so for the optic tract (ICC for 2D-US: 0.95 vs 0.91; 3D-US: 0.94 vs 0.83). Interoperator variability was low for the decussation (2D-US: 0.92; 3D-US: 0.92), but higher for the optic tracts (ICC for 2D-US: 0.80; 3D-US: 0.78). The difference between the mean measurement of the two operators was not statistically significantly different for the decussation, but it was for the optic tracts (P=0.04). The CCA increased steadily between 20 and 30 gestational weeks and plateaued thereafter, at least until 33 weeks. Conclusions The hyperechoic structure evident on 2D-and 3D-US, just below the circle of Willis, is indeed the OC. 2D-US is apparently as good as 3D-US for visualization of the OC. However, only measurement of the decussation showed low intra-and interoperator variability, whereas measurement of the optic tract is of questionable variability. As gestation advances between 20 and 30 weeks, the OC becomes more oblique in orientation. Copyright (C) 2016 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [21] Anterior interhemispheric approach for microsurgical resection of an optic chiasm cavernoma
    Sbeih, Ibrahim
    Darwazeh, Rami
    Shehadeh, Mahmoud
    Nisah, Mahmoud
    Sbeih, Aseel
    Abu-Farsakh, Hussam
    Asseidat, Ibrahim
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2020, 21
  • [22] Cavernous malformation of the optic chiasm: case report
    Muta, Daisuke
    Nishi, Toru
    Koga, Kazunari
    Yamashiro, Shigeo
    Fujioka, Shodo
    Kuratsu, Jun-Ichi
    BRITISH JOURNAL OF NEUROSURGERY, 2006, 20 (05) : 312 - 315
  • [23] The "Hand as Foot" teaching method in optic chiasm
    Li, Dongrui
    Zhang, Jinfeng
    Liu, Xiuzhen
    Liu, Guorong
    ASIAN JOURNAL OF SURGERY, 2023, 46 (03) : 2025 - 2026
  • [24] Solitary metastasis of breast carcinoma in the optic chiasm
    Baeesa, SS
    Benoit, BG
    BRITISH JOURNAL OF NEUROSURGERY, 1999, 13 (03) : 319 - 321
  • [25] Glioma of the optic nerve and chiasm: a case report
    Pas, Camila Batista
    Tanajura, Guilherme Henrique
    Giampani Junior, Jair
    Brito, Amanda Garcia de
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (01)
  • [26] Intra- and interobserver reproducibility study of early fetal growth parameters
    Verburg, Bero O.
    Mulder, Paul G. H.
    Hofman, Albert
    Jaddoe, Vincent W. V.
    Witteman, Jacqueline C. M.
    Steegers, Eric A. P.
    PRENATAL DIAGNOSIS, 2008, 28 (04) : 323 - 331
  • [27] Extrinsic and intrinsic blood supply to the optic chiasm
    Salaud, Celine
    Ploteau, Stephane
    Blery, Pauline
    Pilet, Paul
    Armstrong, Olivier
    Hamel, Antoine
    CLINICAL ANATOMY, 2018, 31 (03) : 432 - 440
  • [28] Microvascular decompression of the optic chiasm Case report
    McLaughlin, Nancy
    Bojanowski, Michel W.
    JOURNAL OF NEUROSURGERY, 2011, 114 (03) : 857 - 860
  • [29] Cavernous hemangioma of the optic chiasm: A surgical review
    Crocker, Matthew
    DeSouza, Ruth
    King, Andrew
    Connor, Steve
    Thomas, Nick
    SKULL BASE-AN INTERDISCIPLINARY APPROACH, 2008, 18 (03): : 201 - 212
  • [30] Quantifying nerve decussation abnormalities in the optic chiasm
    Puzniak, Robert J.
    Ahmadi, Khazar
    Kaufmann, Joern
    Gouws, Andre
    Morland, Antony B.
    Pestilli, Franco
    Hoffmann, Michael B.
    NEUROIMAGE-CLINICAL, 2019, 24