Design of Shimming Rings for Small Permanent MRI Magnet Using Sensitivity-Analysis-Based Particle Swarm Optimization Algorithm

被引:6
作者
Cheng, Yiyuan [1 ]
He, Wei [1 ]
Xia, Ling [1 ]
Liu, Feng [2 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
关键词
Magnetic resonance imaging; Permanent magnet; Shimming ring; Sensitivity analysis; Particle swarm optimization; RESONANCE; FIELDS; ARRAY;
D O I
10.1007/s40846-015-0051-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main magnet in a magnetic resonance imaging (MRI) system creates a static magnetic field that determines the final imaging quality. In a permanent MRI system, shimming rings are commonly used to improve field homogeneity. However, the optimization of the ring structure is challenging owing to the nonlinear properties of the ferromagnetic material. To design a small permanent magnet system, this study explores the application of sensitivity analysis (SA) and particle swarm optimization (PSO) algorithm for the optimization of shimming rings. SA is used to identify the most important parameter of the shimming rings that affects the quality of the magnetic field to simplify the optimization process and improve optimization accuracy and efficiency. PSO is used to solve the complex and nonlinear optimizations of the magnetic field. To illustrate the effectiveness of the proposed method, a specific permanent MRI magnet was modeled. The results show that the inner radius of the shimming ring crucially affects magnetic field quality, with ring height having relatively smaller impact. Compared with the PSO-only optimization procedure, the combined SA-PSO optimization more rapidly converges to a better solution. The optimized shimming rings significantly improve the magnetic field uniformity (similar to 10 fold) compared with that of the initial magnet without shimming rings.
引用
收藏
页码:448 / 454
页数:7
相关论文
共 23 条
[1]   A Survey of Particle Swarm Optimization Applications in Electric Power Systems [J].
AlRashidi, M. R. ;
El-Hawary, M. E. .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2009, 13 (04) :913-918
[2]   A mobile NMR device for measurements of porosity and pore size distributions of drilled core samples [J].
Anferova, S ;
Anferov, V ;
Rata, DG ;
Blümich, B ;
Arnold, J ;
Clauser, C ;
Blümler, P ;
Raich, H .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 23B (01) :26-32
[3]   Sensitivity analysis of model output: Variance-based methods make the difference [J].
Chan, K ;
Saltelli, A ;
Tarantola, S .
PROCEEDINGS OF THE 1997 WINTER SIMULATION CONFERENCE, 1997, :261-268
[4]   Particle swarm optimization: Basic concepts, variants and applications in power systems [J].
del Valle, Yamille ;
Venayagamoorthy, Ganesh Kumar ;
Mohagheghi, Salman ;
Hernandez, Jean-Carlos ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2008, 12 (02) :171-195
[5]   Design optimization of shell and tube heat exchangers using global sensitivity analysis and harmony search algorithm [J].
Fesanghary, M. ;
Damangir, E. ;
Soleimani, I. .
APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) :1026-1031
[6]   Importance measures in global sensitivity analysis of nonlinear models [J].
Homma, T ;
Saltelli, A .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 1996, 52 (01) :1-17
[7]   Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields [J].
Juchem, Christoph ;
Muller-Bierl, Bernd ;
Schick, Fritz ;
Logothetis, Nikos K. ;
Pfeuffer, Josef .
JOURNAL OF MAGNETIC RESONANCE, 2006, 183 (02) :278-289
[8]   A design of permanent magnet array for unilateral NMR device [J].
Kato, Hirokazu ;
Kishi, Kanji ;
Takahashi, Norio ;
Asaumi, Jun-Ichi ;
Honda, Yasutoshi ;
Yanagi, Yoshinobu ;
Aoki, Masaaki .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2008, 33B (03) :201-U2
[9]  
Kennedy J, 1995, 1995 IEEE INTERNATIONAL CONFERENCE ON NEURAL NETWORKS PROCEEDINGS, VOLS 1-6, P1942, DOI 10.1109/icnn.1995.488968
[10]   Passive shim design and a shimming approach for biplanar permanent magnetic resonance imaging magnets [J].
Lopez, Hector Sanchez ;
Liu, Feng ;
Weber, Ewald ;
Crozier, Stuart .
IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (03) :394-402