Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in the selected reaction-monitoring mode for drug analysis

被引:72
作者
Sauvage, Francois-Ludovic [1 ,3 ]
Gaulier, Jean-Michel [1 ]
Lachatre, Gerard [1 ,2 ]
Marquet, Pierre [1 ,3 ]
机构
[1] CHU Limoges, Dept Pharmacol Toxicol, Limoges, France
[2] Univ Limoges, Fac Pharm, Toxicol Lab, Limoges, France
[3] INSERM, U850, Limoges, France
关键词
D O I
10.1373/clinchem.2008.105478
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: We observed cases of false-positive results with the use of liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Different LC-MS/MS techniques that use the selected reaction-monitoring mode, routinely employed for the analysis and quantification of drugs and toxic compounds in biological matrices, were involved in the false-positive and potentially false-positive results obtained. We sought to analyze the causes of and solutions to this problem. METHODS: We used a previously reported LC-MS/MS general unknown screening method, as well as manual spectral investigation in 1 case, to perform verification and identification of interfering compounds. RESULTS: We observed that false-positive results involved: a metabolite of zolpidem that might have been mistaken for lysergic acid diethylamide, benzoylecgonine mistaken for atropine, and clomipramine and 3 phenothiazines that share several common ion transitions. CONCLUSIONS: To prevent problems such as those we experienced, we recommend the use of stable-isotope internal standards when possible, relative retention times, 2 transitions or more per compound when possible, and acceptable relative abundance ratios between transitions, with an experience-based tolerance of +/- 15% for transitions with a relative abundance > 10% and with an extension to +/- 25% for transitions < 10% when the concentration is at the limit of quantification. A powerful general unknown screening procedure can help to confirm suspected interferences. Our results indicate that the specificity of screening procedures is questionable for LC-MS/MS analyses performed in the selected reaction-monitoring mode and involving a large number of compounds with only 1 transition per compound. (C) 2008 American Association for Clinical Chemistry.
引用
收藏
页码:1519 / 1527
页数:9
相关论文
共 38 条
[1]  
Ackermann Bradley L., 2002, Current Topics in Medicinal Chemistry, V2, P53, DOI 10.2174/1568026023394605
[2]  
Aderjans R, 1998, TOXICHEM KRIMTECH, V65, P18
[3]   Interference by venlafaxine ingestion in the detection of tramadol by liquid chromatography linked to tandem mass spectrometry for the screening of illicit drugs in human urine [J].
Allen, KR .
CLINICAL TOXICOLOGY, 2006, 44 (02) :147-153
[4]  
[Anonymous], 2002, FOR TOX LAB GUID
[5]  
[Anonymous], 2003, GUID IND MASS SPECTR
[6]   Quantification by HPLC-MS/MS of atropine in human serum and clinical presentation of six mild-to-moderate intoxicated atropine-adulterated-cocaine users [J].
Boermans, PAMM ;
Go, HS ;
Wessels, AMA ;
Uges, DRA .
THERAPEUTIC DRUG MONITORING, 2006, 28 (03) :295-298
[7]   Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[8]  
Clarkson ED, 1998, CLIN CHEM, V44, P287
[9]   Substance identification: the weak link in analytical toxicology [J].
de Zeeuw, RA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 811 (01) :3-12
[10]   Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring [J].
Gergov, M ;
Ojanperä, I ;
Vuori, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (01) :41-53