Highly sensitive detection of human cardiac myoglobin using a reverse sandwich immunoassay with a gold nanoparticle-enhanced surface plasmon resonance biosensor

被引:91
作者
Gnedenko, Oksana V. [1 ]
Mezentsev, Yury V. [1 ]
Molnar, Andrey A. [1 ]
Lisitsa, Andrey V. [1 ]
Ivanov, Alexis S. [1 ]
Archakov, Alexander I. [1 ]
机构
[1] IBMC RAMS, Moscow 119121, Russia
关键词
Surface plasmon resonance; Reverse sandwich immunoassay; Cardiac myoglobin; Gold nanoparticles; Signal amplification; ACUTE MYOCARDIAL-INFARCTION; PROSTATE-SPECIFIC ANTIGEN; BIOCHEMICAL MARKERS; SPR; ANTIBODIES; DIAGNOSIS; ASSAYS; ELISA; AMPLIFICATION; TECHNOLOGY;
D O I
10.1016/j.aca.2012.10.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive reverse sandwich immunoassay for the detection of human cardiac myoglobin (cMb) in serum was designed utilizing a gold nanoparticle (AuNP)-enhanced surface plasmon resonance (SPR) biosensor. First, a monoclonal anti-cMb antibody (Mab1) was covalently immobilized on the sensor surface. AuNPs were covalently conjugated to the second monoclonal anti-cMb antibody (Mab2) to form an immuno-gold reagent (Mab2-AuNP). The reverse sandwich immunoassay consists of two steps: (I) mixing the serum sample with Mab2-AuNP and incubation for the formation of cMb/Mab2-AuNP complexes and (2) sample injection over the sensor surface and evaluation of the Mab1/cMb/Mab2-AuNP complex formation, with the subsequent calculation of the cMb concentration in the serum. The biosensor signal was amplified approximately 30-fold compared with the direct reaction of cMb with Mab1 on the sensor surface. The limit of detection of cMb in a human blood serum sample was found to be as low as 10 pM (approx. 0.18 ngmL(-1)), and the inter-assay coefficient of variation was less than 3%. Thus, the developed SPR-based reverse sandwich immunoassay has a sensitivity that is sufficient to measure cMb across a wide range of normal and pathological concentrations, allowing an adequate estimation of the disease severity and the monitoring of treatment. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 109
页数:5
相关论文
共 28 条
[21]   Nanoparticle labels in immunosensing using optical detection methods [J].
Seydack, M .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2454-2469
[22]   Electrochemical nanobiosensor for express diagnosis of acute myocardial infarction in undiluted plasma [J].
Suprun, Elena ;
Bulko, Tatiana ;
Lisitsa, Alexander ;
Gnedenko, Oksana ;
Ivanov, Alexis ;
Shumyantseva, Victoria ;
Archakov, Alexander .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (07) :1694-1698
[23]   Enzymatically biocatalytic precipitates amplified antibody-antigen interaction for super low level immunoassay: An investigation combined surface plasmon resonance with electrochemistry [J].
Tanga, Hao ;
Wang, Qiong ;
Xie, Qingji ;
Zhang, Youyu ;
Tan, Liang ;
Yao, Shouzhuo .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (05) :668-674
[24]   Comparative study of SPR and ELISA methods based on analysis of CD166/ALCAM levels in cancer and control human sera [J].
Vaisocherova, Hana ;
Faca, Vitor M. ;
Taylor, Allen D. ;
Hanash, Samir ;
Jiang, Shaoyi .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) :2143-2148
[25]   Fe3O4 nanoparticles-enhanced SPR sensing for ultrasensitive sandwich bio-assay [J].
Wang, Jianlong ;
Zhu, Zanzan ;
Munir, Ahsan ;
Zhou, H. Susan .
TALANTA, 2011, 84 (03) :783-788
[26]   Aptamer-Au NPs conjugates-enhanced SPR sensing for the ultrasensitive sandwich immunoassay [J].
Wang, Jianlong ;
Munir, Ahsan ;
Li, Zhonghong ;
Zhou, H. Susan .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) :124-129
[27]   Application of impedance spectroscopy for monitoring colloid Au-enhanced antibody immobilization and antibody-antigen reactions [J].
Wang, MJ ;
Wang, LY ;
Wang, G ;
Ji, XH ;
Bai, YB ;
Li, TJ ;
Gong, SY ;
Li, JH .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :575-582
[28]   Sensitivity-enhancement of wavelength-modulation surface plasmon resonance biosensor for human complement factor 4 [J].
Xia, L ;
Ying, S ;
Song, DQ ;
Zhang, QL ;
Yuan, T ;
Bi, SY ;
Zhang, HQ .
ANALYTICAL BIOCHEMISTRY, 2004, 333 (01) :99-104