Simultaneous quantification of tiloronoxim and tilorone in human urine by liquid chromatography-tandem mass spectrometry

被引:4
作者
Zhang, Xianhua [1 ,2 ]
Yang, Li [1 ]
Zhai, Suodi [1 ]
Duan, Jingli [1 ,2 ]
机构
[1] Peking Univ, Hosp 3, Dept Pharm, Beijing 100083, Peoples R China
[2] Ctr Therapeut Drugs Monitoring & Clin Toxicol, Beijing 100083, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 875卷 / 02期
关键词
Tiloronoxim; Tilorone; LC-MS/MS; Urine;
D O I
10.1016/j.jchromb.2008.09.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple. sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3000 mass spectrometer was equipped with a TurbolonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3 -> 100.0, m/z 411.3 -> 100.0 and m/z 268.3 -> 116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard Curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput Of Urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers. (C) 2008 Elsevier BY. All rights reserved.
引用
收藏
页码:349 / 357
页数:9
相关论文
共 12 条
  • [1] High-resolution CT in the evaluation of occupational and environmental disease
    Akira, M
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2002, 40 (01) : 43 - +
  • [2] DYNAMIC-PROGRAMMING APPROACH TO THE SINGLE-MACHINE SEQUENCING PROBLEM WITH DIFFERENT DUE-DATES
    CHENG, TCE
    [J]. COMPUTERS & MATHEMATICS WITH APPLICATIONS, 1990, 19 (02) : 1 - 7
  • [3] CHENG YH, 1992, J HYG RES, V21, P1
  • [4] Conglomerated masses of silicosis in sandblasters: High-resolution CT findings
    Marchiori, Edson
    Ferreira, Angela
    Saez, Flavia
    Gabetto, Jose Manoel
    Souza, Arthur Soares, Jr.
    Escuissato, Dante L.
    Gasparetto, Emerson L.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (01) : 56 - 59
  • [5] Systemic silicosis that involves the pancreas
    Papachristou, GI
    Papachristou, DJ
    Schoedel, K
    McGrath, K
    Slivka, A
    [J]. GASTROINTESTINAL ENDOSCOPY, 2006, 63 (01) : 170 - 172
  • [6] SHARGEL L, 2005, APPL BIOPHARMACEUTIC, P216
  • [7] STARK P, 1992, RADIOL CLIN N AM, V30, P1147
  • [8] WANG L, 2005, CHIN J IND MED, V18, P292
  • [9] [杨丽 YANG Li], 2006, [中国新药杂志, Chinese Journal New Drugs], V15, P891
  • [10] PREPARATION AND IN-VITRO EVALUATION OF TETRANDRINE-ENTRAPPED ALBUMIN MICROSPHERES AS AN INHALED DRUG-DELIVERY SYSTEM
    ZENG, XM
    MARTIN, GP
    MARRIOTT, C
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1995, 3 (02) : 87 - 93