The validity and reliability of the exposure index as a metric for estimating the radiation dose to the patient

被引:8
作者
Erenstein, H. G. [1 ]
Browne, D. [3 ]
Curtin, S. [2 ]
Dwyer, R. S. [4 ]
Higgins, R. N. [2 ]
Hommel, S. F. [1 ]
Menzinga, J. [1 ]
Jorge, J. A. Pires [5 ]
Sauty, M. [5 ]
de Vries, G. [6 ]
England, A. [2 ]
机构
[1] Hanze Univ Appl Sci, Dept Med Imaging & Radiat Therapy, Groningen, Netherlands
[2] Univ Salford, Directorate Allied & Publ Hlth, Salford, Lancs, England
[3] Tameside & Glossop Integrated Care Unit NHS Fdn T, Ashton Under Lyne, England
[4] Univ Johannesburg, Dept Med Imaging & Radiat Sci, Johannesburg, South Africa
[5] HES SO Univ Appl Sci & Arts Western Switzerland, Sch Hlth Sci HESAV, Delemont, Switzerland
[6] Inholland Univ Appl Sci, Dept Med Imaging & Radiat Therapy, Haarlem, Netherlands
关键词
Exposure index; Radiation dose; Radiography; DIGITAL RADIOGRAPHY;
D O I
10.1016/j.radi.2020.03.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: With the introduction of digital radiography, the feedback between image quality and overexposure has been partly lost which in some cases has led to a steady increase in dose. Over the years the introduction of exposure index (EI) has been used to resolve this phenomenon referred to as 'dose creep'. Even though EI is often vendor specific it is always a related of the radiation exposure to the detector. Due to the nature of this relationship EI can also be used as a patient dose indicator, however this is not widely investigated in literature. Methods: A total of 420 dose-area-product (DAP) and EI measurements were taken whilst varying kVp, mAs and body habitus on two different anthropomorphic phantoms (pelvis and chest). Using linear regression, the correlation between EI and DAP were examined. Additionally, two separate region of interest (ROI) placements/per phantom where examined in order to research any effect on EI. Results: When dividing the data into subsets, a strong correlation between EI and DAP was shown with all R-squared values > 0.987. Comparison between the ROI placements showed a significant difference between EIs for both placements. Conclusion: This research shows a clear relationship between EI and radiation dose which is dependent on a wide variety of factors such as ROI placement, body habitus. In addition, pathology and manufacturer specific EI's are likely to be of influence as well. Implications for practice: The combination of DAP and EI might be used as a patient dose indicator. However, the influencing factors as mentioned in the conclusion should be considered and examined before implementation. (C) 2020 The College of Radiographers. Published by Elsevier Ltd.
引用
收藏
页码:S94 / S99
页数:6
相关论文
共 50 条
  • [21] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [22] Automated Framework for Digital Radiation Dose Index Reporting From CT Dose Reports
    Shih, George
    Lu, Zheng Feng
    Zabih, Ramin
    Kennedy, Devin
    Loftus, Michael
    Shih, Wei-Jen
    Osborne, Joseph
    Nickoloff, Edward
    Schwartz, Lawrence
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : 1170 - 1174
  • [23] Radiation Dose to PET Technologists and Strategies to Lower Occupational Exposure
    Roberts, Fiona O.
    Gunawardana, Dishan H.
    Pathmaraj, Kunthi
    Wallace, Anthony
    Paul, L. U.
    Mi, Tian
    Berlangieri, Sam U.
    O'Keefe, Graeme J.
    Rowe, Chris C.
    Scott, Andrew M.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2005, 33 (01) : 44 - 47
  • [24] Automatic patient centering for MDCT: Effect on radiation dose
    Li, Jianhai
    Udayasankar, Unni K.
    Toth, Thomas L.
    Seamans, John
    Small, William C.
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 547 - 552
  • [25] Monitoring clinical exposure index and deviation index for dose optimization based on national diagnostic reference level: Focusing on general radiography of extremities
    Park, Hyemin
    Yoon, Yongsu
    Kim, Eunhye
    Jeong, Hoiwoun
    Kim, Jungsu
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 419 - 432
  • [26] Patient radiation exposure during general fluoroscopy examinations
    Wambani, Jeska S.
    Korir, Geoffrey K.
    Tries, Mark A.
    Korir, Ian K.
    Sakwa, Jedidah M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 262 - 270
  • [27] Patient exposure dose for chest and skull radiographies in Mazandaran hospitals
    Etemadinezhad, Siavash
    Rahimi, Seyed Ali
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (01) : 87 - 91
  • [28] Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT
    Kanal, Kalpana M.
    Stewart, Brent K.
    Kolokythas, Orpheus
    Shuman, William P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (01) : 219 - 225
  • [29] New patient-controlled abdominal compression method in radiography: radiation dose and image quality
    Piippo-Huotari, Oili
    Norrman, Eva
    Anderzen-Carlsson, Agneta
    Geijer, Hakan
    ACTA RADIOLOGICA OPEN, 2018, 7 (05): : 1 - 8
  • [30] Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Christopher H.
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2017, 44 (08) : 4262 - 4275