An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging

被引:24
作者
Larkman, DJ [1 ]
deSouza, NM [1 ]
Bydder, M [1 ]
Hajnal, JV [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Robert Steiner MRI Unit, London W12 0HS, England
关键词
breast; contrast; SENSE; gadolinium; parallel imaging;
D O I
10.1002/jmri.1190
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gadolinium-enhanced dynamic magnetic resonance (MR) imaging is playing an increasingly important diagnostic role in patients with breast cancer. Because of the multi-focal nature of the disease, it is mandatory to cover all of both breasts, not only in the initial scan, but also at subsequent follow-up. This requires volume acquisitions with a temporal resolution limited to 60-80 seconds, which is insufficient to clearly discriminate malignant from benign rates of contrast uptake. In this work, we performed sensitivity-encoded imaging using a commercially available four-channel breast coil (MRI Devices Corporation) on a commercial 0.5-T scanner with moderate gradient performance to give increased temporal resolution in these dynamic contrast-enhanced scans. A two-fold increase in temporal resolution was readily achievable with this coil. Image reconstruction was robust and image quality was assessed qualitatively to be good. We also investigated higher speed-up factors using two directions of sensitivity-encoded reduction and discussed some of the potential artifacts associated with such imaging. J. Magn. Reson. Imaging 2001;14:329-335. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 46 条
[21]   Discrimination between benign and malignant breast lesions using volumetric quantitative dynamic contrast-enhanced MR imaging [J].
Cheng, Ziliang ;
Wu, Zhuo ;
Shi, Guangzi ;
Yi, Zhilong ;
Xie, Mingwei ;
Zeng, Weike ;
Song, Chao ;
Zheng, Chushan ;
Shen, Jun .
EUROPEAN RADIOLOGY, 2018, 28 (03) :982-991
[22]   Discrimination between benign and malignant breast lesions using volumetric quantitative dynamic contrast-enhanced MR imaging [J].
Ziliang Cheng ;
Zhuo Wu ;
Guangzi Shi ;
Zhilong Yi ;
Mingwei Xie ;
Weike Zeng ;
Chao Song ;
Chushan Zheng ;
Jun Shen .
European Radiology, 2018, 28 :982-991
[23]   Differentiation between benign and malignant breast lesions detected by bilateral dynamic contrast-enhanced MRI: A sensitivity and specificity study [J].
Jansen, Sanaz A. ;
Fan, Xiaobing ;
Karczmar, Gregory S. ;
Abe, Hiroyuki ;
Schmidt, Robert A. ;
Newstead, Gillian M. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) :747-754
[24]   Combination of low and high resolution sequences in two orientations for dynamic contrast-enhanced MRI of the breast: more than a compromise [J].
Vomweg, TW ;
Teifke, A ;
Kunz, RP ;
Hintze, C ;
Hlawatsch, A ;
Kern, A ;
Kreitner, KF ;
Thelen, M .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1732-1742
[25]   Combination of low and high resolution sequences in two orientations for dynamic contrast-enhanced MRI of the breast: more than a compromise [J].
Toni W. Vomweg ;
Andrea Teifke ;
R. Peter Kunz ;
Christian Hintze ;
Alexander Hlawatsch ;
Annett Kern ;
Karl F. Kreitner ;
Manfred Thelen .
European Radiology, 2004, 14 :1732-1742
[26]   Quality assurance in MRI breast screening: comparing signal-to-noise ratio in dynamic contrast-enhanced imaging protocols [J].
Kousi, Evanthia ;
Borri, Marco ;
Dean, Jamie ;
Panek, Rafal ;
Scurr, Erica ;
Leach, Martin O. ;
Schmidt, Maria A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) :37-49
[27]   Abbreviated breast MRI combining FAST protocol and high temporal resolution (HTR) dynamic contrast enhanced (DCE) sequence [J].
Milon, Audrey ;
Vande Perre, Saskia ;
Poujol, Julie ;
Trop, Isabelle ;
Kermarrec, Edith ;
Bekhouche, Asma ;
Thomassin-Naggara, Isabelle .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 117 :199-208
[28]   Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7 T [J].
van der Velden, Tijl A. ;
Schmitz, Alexander M. Th. ;
Gilhuijs, Kenneth G. A. ;
Veldhuis, Wouter B. ;
Luijten, Peter R. ;
Boer, Vincent O. ;
Klomp, Dennis W. J. .
MAGNETIC RESONANCE IMAGING, 2016, 34 (04) :462-468
[29]   High temporal resolution dynamic contrast-enhanced MRI using compressed sensing-combined sequence in quantitative renal perfusion measurement [J].
Chen, Bin ;
Zhao, Kai ;
Li, Bo ;
Cai, Wenchao ;
Wang, Xiaoying ;
Zhang, Jue ;
Fang, Jing .
MAGNETIC RESONANCE IMAGING, 2015, 33 (08) :962-969
[30]   Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging [J].
Benkert, Thomas ;
Block, Kai Tobias ;
Heller, Samantha ;
Moccaldi, Melanie ;
Sodickson, Daniel K. ;
Kim, Sungheon Gene ;
Moy, Linda .
INVESTIGATIVE RADIOLOGY, 2017, 52 (10) :583-589