The effect of monomer-to-powder ratio on the material properties of cranioplastic

被引:29
作者
Jasper, LE [1 ]
Deramond, H [1 ]
Mathis, JM [1 ]
Belkoff, SM [1 ]
机构
[1] Univ Maryland, Dept Surg, Div Orthopaed Surg, Orthopaed Biomech Lab, Baltimore, MD 21201 USA
关键词
bone cement; polymethylmethacrylate; monomer; strength; modulus; biomechanical testing; vertebroplasty;
D O I
10.1016/S8756-3282(99)00129-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Percutaneous vertebroplasty consists of injecting polymethylmethacrylate cement into the cancellous bone of vertebral bodies for the treatment of various lesions of the spine, including osteoporotic compression fractures. Clinicians practicing vertebroplasty commonly alter the mixture of monomer-to-powder recommended by the manufacturer in an effort to decrease viscosity and increase the working time. The purpose of the current study was to measure the effect that varying the monomer-to-powder ratio has on the compressive material properties of a cement (Cranioplastic) commonly used in vertebroplasty, Cylindrical specimens were prepared varying a monomer-to-polymer ratio of 0.40 to 1.07 mL/g and tested per the American Society for Testing and Materials standard F451. Specimens prepared at 0.53 mL/g, which is near the manufacturer's recommended monomer-to-polymer mixture of 0.57 mL/g, exhibited the greatest mean values for ultimate compressive stress, yield stress, and elastic modulus. Specimens prepared at higher or lower ratios exhibited diminished strength, in some cases by as much as 24%. Although altering the monomer-to-powder ratio affects the cement's material properties, it is as Set unknown if the decrease Is clinically significant. (Bone 25:27S-29S 1999) (C) 1999 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:27S / 29S
页数:3
相关论文
共 13 条
  • [1] Percutaneous vertebroplasty: State of the art
    Cotten, A
    Boutry, N
    Cortet, B
    Assaker, R
    Demondion, X
    Leblond, D
    Chastanet, P
    Duquesnoy, B
    Deramond, H
    [J]. RADIOGRAPHICS, 1998, 18 (02) : 311 - 320
  • [2] INFLUENCE OF ANTIBIOTIC IMPREGNATION ON THE FATIGUE LIFE OF SIMPLEX-P AND PALACOS-R ACRYLIC BONE CEMENTS, WITH AND WITHOUT CENTRIFUGATION
    DAVIES, JP
    OCONNOR, DO
    BURKE, DW
    HARRIS, WH
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (04): : 379 - 397
  • [3] EFFECT OF HAND MIXING TOBRAMYCIN ON THE FATIGUE-STRENGTH OF SIMPLEX-P
    DAVIES, JP
    HARRIS, WH
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (11): : 1409 - 1414
  • [4] Debussche-Depriester C., 1991, NEURORADIOLOGY, V33, P149
  • [5] Deramond H., 1997, Semin Musculoskelet Radiol, V1, P285, DOI 10.1055/s-2008-1080150
  • [6] GALIBERT P, 1987, NEUROCHIRURGIE, V33, P166
  • [7] CHARACTERIZATION OF POLYMETHYLMETHACRYLATE BONE CEMENT
    HAAS, SS
    BRAUER, GM
    DICKSON, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, A 57 (03) : 380 - 391
  • [8] Jensen ME, 1997, AM J NEURORADIOL, V18, P1897
  • [9] LAPRAS C, 1989, ANN CHIR, V43, P371
  • [10] Mathis JM, 1998, ARTHRITIS RHEUM, V41, P171, DOI 10.1002/1529-0131(199801)41:1<171::AID-ART21>3.3.CO