LC-MS/MS approaches for the assay of bis-quaternary pyridinium oximes used as AChE reactivators in biological matrices

被引:0
作者
Voicu, Victor [1 ,2 ]
Albu, Florin [3 ]
Tache, Florentin [4 ]
Musilek, Kamil [5 ]
Kuca, Kamil [5 ,6 ]
Medvedovici, Andrei [3 ,4 ]
机构
[1] Univ Med & Pharm Carol Davila, Fac Med, Dept Clin Pharmacol Toxicol & Psychopharmacol, Bucharest 011643, Romania
[2] Romanian Army Ctr Med Res, Bucharest 020012, Romania
[3] SC Labormed Pharma SA, Bioanalyt Lab, Bucharest 032266, Romania
[4] Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest 050663, Romania
[5] Univ Hradec Kralove, Fac Sci, Dept Chem, Hradec Kralove 50003, Czech Republic
[6] Univ Def, Fac Mil Hlth Sci, Ctr Adv Studies, Hradec Kralove 50001, Czech Republic
关键词
TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; FAST-ATOM-BOMBARDMENT; ION-PAIRING AGENTS; ACETYLCHOLINESTERASE REACTIVATORS; PRALIDOXIME; 2-PAM; NERVE AGENTS; AMINO-ACIDS; HI-6; RETENTION;
D O I
10.4155/BIO.13.41
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Extreme efforts are made for the structural diversification of oximes used as AChE reactivators. Co-administration of different oximes should also be considered as a solution in therapy. Consequently, development of selective assays of oximes in biological matrices is of major importance. Results: Three chromatographic separation mechanisms were evaluated: hydrophilic-interaction LC; mixed reversed-phase/cation exchange (DUET); and reversed-phase ion pairing based on per-fluorinated agents. MS was used to identify and quantify oximes. Alternative preparation of whole blood and plasma samples were used based on protein precipitation through addition of acetonitrile or ionic liquids. Quality characteristics of the proposed analytical approaches are discussed. Conclusion: The reversed-phase ion pairing based on per-fluorinated agents chromatographic separation mechanism and positive ESI-MS/MS detection produced the best results for the assay of bis-quaternary pyridinium oximes. LLOQ in the tenths of nanogram per milliliter range are achievable.
引用
收藏
页码:793 / 809
页数:17
相关论文
共 33 条
  • [1] High-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of diazepam, atropine and pralidoxime in human plasma
    Abbara, Chadi
    Bardot, Isabelle
    Cailleux, Annie
    Lallement, Guy
    Le Bouil, Anne
    Turcant, Alain
    Clair, Pascal
    Diquet, Bertrand
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 874 (1-2): : 42 - 50
  • [2] FAST-ATOM-BOMBARDMENT, FRIT FAST-ATOM-BOMBARDMENT AND ELECTROSPRAY-IONIZATION MASS-SPECTROMETRIC STUDY OF ORGANIC SALTS C2+ 2X(-) - MATRIX AND ANION EFFECTS
    AUBAGNAC, JL
    GILLES, I
    CALAS, M
    CORDINA, G
    PIQUET, G
    PORTEFAIX, P
    GIRAL, L
    [J]. JOURNAL OF MASS SPECTROMETRY, 1995, 30 (07): : 985 - 992
  • [3] Purity of antidotal oxime HI-6 DMS as an active pharmaceutical ingredient for auto-injectors and infusions
    Bogan, Reinhard
    Koller, Marianne
    Klaubert, Bernd
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (3-4) : 199 - 207
  • [4] Photostability of antidotal oxime HI-6, impact on drug development
    Bogan, Reinhard
    Worek, Franz
    Koller, Marianne
    Klaubert, Bernd
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (3-4) : 208 - 214
  • [5] Development and validation of a sensitive HPLC method for the quantification of HI-6 in guinea pig plasma and evaluated in domestic swine
    Bohnert, Sara
    Vair, Cory
    Mikler, John
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (17-18): : 1407 - 1413
  • [6] A liquid chromatographic-mass spectrometric (LC-MS) method for the analysis of the bis-pyridinium oxime ICD-585 in plasma: Application in a guinea pig model
    Capacio, B. R.
    Dusick, B.
    Smith, J. R.
    McDonough, J. H.
    Shih, T-M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (17-18): : 1420 - 1425
  • [7] DAgostino PA, 1996, RAPID COMMUN MASS SP, V10, P805
  • [8] European Medicines Agency, 2009, GUIDELINE ON VALIDAT
  • [9] Simple high-performance liquid chromatographic method for determination of atropine and obidoxime in a parenteral injection device
    Gören, AC
    Bilsel, G
    Bilsel, M
    Yenisoy-Karakas, S
    Karakas, D
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) : 237 - 239
  • [10] Quantification of pralidoxime (2-PAM) in urine by ion pair chromatography-diode array detection: application to in vivo samples from minipig
    John, Harald
    Eddleston, Michael
    Clutton, R. Eddie
    Worek, Franz
    Thiermann, Horst
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (3-4) : 169 - 178