A Wearable Cellulose Acetate-Coated Mouthguard Biosensor for In Vivo Salivary Glucose Measurement

被引:208
作者
Arakawa, Takahiro [2 ]
Tomoto, Keisuke [1 ]
Nitta, Hiroki [2 ]
Toma, Koji [2 ]
Takeuchi, Shuhei [3 ]
Sekita, Toshiaki [3 ]
Minakuchi, Shunsuke [3 ]
Mitsubayashi, Kohji [1 ,2 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Bunkyo Ku, Tokyo 1138510, Japan
[2] Tokyo Med & Dent Univ, Dept Biomed Devices & Instrumentat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[3] Tokyo Med & Dent Univ, Gerodontol & Oral Rehabil, Bunkyo Ku, Tokyo 1138549, Japan
基金
日本学术振兴会;
关键词
SENSORS; BIOCOMPATIBILITY; ACETONE; SYSTEM;
D O I
10.1021/acs.analchem.0c01201
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a cellulose acetate (CA) membrane is formed as an interference rejection membrane on a glucose sensor to measure glucose in saliva. Glucose in saliva is successfully measured in vivo without any pretreatment of human saliva. A mouthguard (MG) glucose sensor is developed to monitor salivary glucose, which is reported to be correlated with the blood glucose level. Salivary components of ascorbic acid (AA) and uric acid (UA) hinder the accurate measurement of the glucose concentration of human saliva. CA-coated electrodes are prepared to investigate the interference rejection membrane. To measure hydrogen peroxide, which is a reaction product of glucose oxidase, effects of AA and UA are examined. Characteristics of the fabricated biosensor are examined on the basis of artificial saliva. The as-developed MG sensor can quantify the glucose concentration in the range of 1.75-10 000 mu mol/L, which includes a salivary sugar concentration of 20-200 mu mol/L. For the measurement of saliva samples collected from healthy subjects, the output corresponding to the concentration is confirmed; this suggests the possibility of glucose measurement. This MG glucose sensor can provide a useful method for the unrestricted and noninvasive monitoring of saliva glucose for the management of diabetes patients.
引用
收藏
页码:12201 / 12207
页数:7
相关论文
共 41 条
[1]   Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor [J].
Arakawa, Takahiro ;
Kuroki, Yusuke ;
Nitta, Hiroki ;
Chouhan, Prem ;
Toma, Koji ;
Sawada, Shin-ichi ;
Takeuchi, Shuhei ;
Sekita, Toshiaki ;
Akiyoshi, Kazunari ;
Minakuchi, Shunsuke ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2016, 84 :106-111
[2]   The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System [J].
Bailey, Timothy ;
Bode, Bruce W. ;
Christiansen, Mark P. ;
Klaff, Leslie J. ;
Alva, Shridhara .
DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) :787-794
[3]   Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study [J].
Bandodkar, Amay J. ;
Jia, Wenzhao ;
Yardimci, Ceren ;
Wang, Xuan ;
Ramirez, Julian ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :394-398
[4]   Non-invasive wearable electrochemical sensors: a review [J].
Bandodkar, Amay J. ;
Wang, Joseph .
TRENDS IN BIOTECHNOLOGY, 2014, 32 (07) :363-371
[5]   Glucose Sensing for Diabetes Monitoring: Recent Developments [J].
Bruen, Danielle ;
Delaney, Colm ;
Florea, Larisa ;
Diamond, Dermot .
SENSORS, 2017, 17 (08)
[6]   The worldwide epidemiology of type 2 diabetes mellitus-present and future perspectives [J].
Chen, Lei ;
Magliano, Dianna J. ;
Zimmet, Paul Z. .
NATURE REVIEWS ENDOCRINOLOGY, 2012, 8 (04) :228-236
[7]   Biochemical Gas Sensors (Biosniffers) Using Forward and Reverse Reactions of Secondary Alcohol Dehydrogenase for Breath Isopropanol and Acetone as Potential Volatile Biomarkers of Diabetes Mellitus [J].
Chien, Po-Jen ;
Suzuki, Takuma ;
Tsujii, Masato ;
Ye, Ming ;
Minami, Isao ;
Toda, Kanako ;
Otsuka, Hiromi ;
Toma, Koji ;
Arakawa, Takahiro ;
Araki, Kouji ;
Iwasaki, Yasuhiko ;
Shinada, Kayoko ;
Ogawa, Yoshihiro ;
Mitsubayashi, Kohji .
ANALYTICAL CHEMISTRY, 2017, 89 (22) :12261-12268
[8]   Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents [J].
Chu, MingXing ;
Shirai, Takayuki ;
Takahashi, Daishi ;
Arakawa, Takahiro ;
Kudo, Hiroyuki ;
Sano, Kenji ;
Sawada, Shin-ichi ;
Yano, Kazuyoshi ;
Iwasaki, Yasuhiko ;
Akiyoshi, Kazunari ;
Mochizuki, Manabu ;
Mitsubayashi, Kohji .
BIOMEDICAL MICRODEVICES, 2011, 13 (04) :603-611
[9]   Blood, sweat, and tears: developing clinically relevant protein biosensors for integrated body fluid analysis [J].
Corrie, S. R. ;
Coffey, J. W. ;
Islam, J. ;
Markey, K. A. ;
Kendall, M. A. F. .
ANALYST, 2015, 140 (13) :4350-4364
[10]   Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring [J].
de Castro, Lucas F. ;
de Freitas, Soraia V. ;
Duarte, Lucas C. ;
de Souza, Joao Antonio C. ;
Paixao, Thiago R. L. C. ;
Coltro, Wendell K. T. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (19) :4919-4928