Artifact reduction strategies for prosthetic heart valve CT imaging

被引:16
作者
Habets, Jesse [1 ]
Symersky, Petr [2 ]
Leiner, Tim [1 ]
de Mol, Bas A. J. M. [2 ]
Mali, Willem P. Th M. [1 ]
Budde, Ricardo P. J. [1 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
[3] Gelre Hosp, Dept Radiol, Apeldoorn, Netherlands
关键词
Computed tomography; Prosthetic heart valve; Metal artifact reduction; Iterative reconstruction; Tube voltage; COMPUTED-TOMOGRAPHY; ECHOCARDIOGRAPHY;
D O I
10.1007/s10554-012-0041-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multislice CT evaluation of prosthetic heart valves (PHV) is limited by PHV-related artifacts. We assessed the influence of different kV settings, a metal artifact reduction filter (MARF) and an iterative reconstruction algorithm (IR) on PHV-induced artifacts in an in vitro model. A Medtronic-Hall tilting disc and St Jude bileafet PHV were imaged using a 64-slice scanner with 100 kV/165 mAs, 120 kV/100 mAs, 140 kV/67 mAs at an equal CTDIvol. Images were reconstructed with (1) filtered back projection (FBP), (2) IR, (3) MARF and (4) MARF and IR. Hypo- and hyperdense artifacts volumes (mean mm(3) +/- SD) were quantified with 2 thresholds (<=-50 and >= 175 Hounsfield Units). Image noise was measured and the presence of secondary artifacts was scored by 2 observers independently. Mean hypodense artifacts for the Medtronic-Hall/St Jude valve (FBP) were 966 +/- 23/1,738 +/- 21 at 100 kV, 610 +/- 13/991 +/- 12 at 120 kV, and 420 +/- 9/634 +/- 9 at 140 kV. Compared to FBP, hypodense artifact reductions for IR were 9/8 %, 10/7 % and 12/6 % respectively, for MARF 92 %/84 %, 89/81 % and 86/77 % respectively; for MARF + IR 94/85 %, 92/82 %, and 90/79 % respectively. Mean hyperdense artifacts for the Medtronic-Hall/St Jude valve were 5,530 +/- 48/6,940 +/- 70 at 100 kV, 5,120 +/- 42/6,250 +/- 53 at 120 kV, and 5,011 +/- 52/6,000 +/- 0 at 140 kV. Reductions for IR were 2/2 %, 2/3 % and 3/4 % respectively, for MARF were 9/30 %, 0/25 %, 5/22 % respectively, MARF + IR 12/32 %, 4/27 % and 7/25 % respectively. Secondary artifacts were found in all MARF images. Image noise was reduced in the IR images. In vitro PHV-related artifacts can be reduced by increasing kV despite maintaining identical CTDIvol. Although MARF is more effective than IR, it induces secondary artifacts.
引用
收藏
页码:2099 / 2108
页数:10