DETERMINATION OF ESTROGENS IN WATER SAMPLES BY IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

被引:24
|
作者
Wu, Cui-Qin [1 ]
Chen, Di-Yun [1 ]
Feng, Yin-Si [1 ]
Deng, Hong-Mei [1 ]
Liu, Yong-Hui [1 ]
Zhou, Ai-Ju [2 ]
机构
[1] Guangzhou Univ, Sch Environm Sci & Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangzhou Univ, Sch Chem & Chem Engn, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Dispersive liquid-liquid microextraction; Estrogens; Fluorescence detector; Ionic liquid; Photodiode array detector; SOLID-PHASE MICROEXTRACTION; TANDEM MASS-SPECTROMETRY; STEROID SEX-HORMONES; GAS-CHROMATOGRAPHY; DISRUPTING COMPOUNDS; WASTE-WATER; EXTRACTION; UV; OPTIMIZATION; ENDOCRINE;
D O I
10.1080/00032719.2012.680086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) ionic liquid as extraction solvent, five estrogens including estrone (E-1), 17 beta-estradiol (E-2), estriol (E-3), 17 alpha-ethynylestradiol (EE2), and diethylstilbestrol (DES) in water samples were determined by dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with a photodiode array detector and a fluorescence detector (HPLC-DAD-FLD). The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of [C6MIM][PF6] dispersed entirely into the sample solution with the help of a disperser solvent (acetone). Parameters including both extraction and disperser solvents and their volumes, extraction and centrifugal time, sample pH, and salt effect were investigated and optimized. Under the optimized conditions, 110-349 fold enrichment factors of analytes were obtained. The calibration curves were linear in the concentration range of 0.2-100 mu g L-1 for E-2, E-3, and EE2 detected with FLD, and 1-100 mu g L-1 for E-1 and DES detected with DAD. The correlation coefficient of the calibration curve was between 0.9990 and 0.9997. The limits of detection (LOD, S/N = 3) for the five estrogens were in the range of 0.08-0.5 mu g L-1. The relative standard deviations (RSD) for six replication experiments at the concentration of 5.0 mu g L-1 were <= 5.7%. The proposed method was applied to the analysis of three water samples from different sources (river water, waste water, and sea water). The relative recoveries of spiked water samples are satisfied with 89.3-102.4% and 88.7-105.2% at two different concentration levels of 5.0 and 50.0 mu g L-1, respectively.
引用
收藏
页码:1995 / 2005
页数:11
相关论文
共 50 条
  • [1] Ionic liquid-based dispersive liquid-liquid microextraction combined with ultra performance liquid chromatography for the determination of metal ions
    Razmisleviciene, Ina
    Olsauskaite, Vilma
    Padarauskas, Audrius
    CHEMIJA, 2011, 22 (04): : 197 - 203
  • [2] Determination of Estrogens in Water Samples Using Dispersive Liquid Liquid Microextraction and High Performance Liquid Chromatography
    Hadjmohammadi, Mohammad Reza
    Ghoreishi, Seyedeh Saboora
    ACTA CHIMICA SLOVENICA, 2011, 58 (04) : 765 - 771
  • [3] Ionic liquid-based dispersive liquid-liquid microextraction followed high-performance liquid chromatography for the determination of organophosphorus pesticides in water sample
    He, Lijun
    Luo, Xianli
    Xie, Hongxue
    Wang, Chunjian
    Jiang, Xiuming
    Lu, Kui
    ANALYTICA CHIMICA ACTA, 2009, 655 (1-2) : 52 - 59
  • [4] Ionic-liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography for the determination of multiclass pesticide residues in water samples
    Tadesse, Bezuayehu
    Teju, Endale
    Gure, Abera
    Megersa, Negussie
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (05) : 829 - 835
  • [5] USE OF IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY TO DETECT FORMALDEHYDE IN AIR, WATER, AND SOIL SAMPLES
    Peng, Bing
    Zhang, Jiaheng
    Wu, Chenghao
    Li, Songqing
    Li, Yubo
    Gao, Haixiang
    Lu, Runhua
    Zhou, Wenfeng
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (06) : 815 - 828
  • [6] Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection
    Zhang, Rui
    Wang, Chuanliu
    Yue, Qiaohong
    Zhou, Tiecheng
    Li, Na
    Zhang, Hanqi
    Hao, Xiaoke
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (21) : 3133 - 3141
  • [7] Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with Flame Atomic Absorption Spectrometry for Determination of Silver in Water Samples
    Abadi, M. Dehghani Mohammad
    Chamsaz, M.
    Arbab-Zavar, M. H.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (07) : 3984 - 3988
  • [8] Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Following High-Performance Liquid Chromatography for the Determination of Fungicides in Fruit Juices
    Wang, Suli
    Liu, Congyun
    Yang, Suping
    Liu, Fengmao
    FOOD ANALYTICAL METHODS, 2013, 6 (02) : 481 - 487
  • [9] Ionic liquid dispersive liquid-liquid microextraction combined with high performance liquid chromatography for determination of tetracycline drugs in eggs
    Song, Jiao
    Zhang, Zhen Hong
    Zhang, Ying Qun
    Feng, Cheng
    Wang, Geng Nan
    Wang, Jian Ping
    ANALYTICAL METHODS, 2014, 6 (16) : 6459 - 6466
  • [10] Dispersive liquid-liquid microextraction based on ionic liquid in combination with high-performance liquid chromatography for the determination of bisphenol A in water
    Li, Yu
    Liu, Jianlin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (11) : 880 - 890