Control of DFIG Wind Turbine With Direct-Current Vector Control Configuration

被引:128
作者
Li, Shuhui [1 ]
Haskew, Timothy A. [1 ]
Williams, Keith A. [2 ]
Swatloski, Richard P. [3 ]
机构
[1] Univ Alabama, Dept Elect & Comp Engn, Tuscaloosa, AL 35487 USA
[2] Univ Alabama, Dept Mech Engn, Tuscaloosa, AL 35487 USA
[3] Univ Alabama, Off Technol Transfer, Tuscaloosa, AL 35487 USA
基金
美国国家科学基金会;
关键词
DC-link voltage control; direct-current vector control; doubly-fed induction generator (DFIG) wind turbine; grid voltage support control; maximum power extraction; reactive power control; POWER-CONTROL; EXTRACTION;
D O I
10.1109/TSTE.2011.2167001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The doubly-fed induction generator (DFIG) wind turbine is a variable speed wind turbine widely used in the modern wind power industry. At present, commercial DFIG wind turbines primarily make use of the technology that was developed a decade ago. But, it is found in this paper that there is a limitation in the conventional vector control technique. This paper presents a directcurrent vector control method in a DFIG wind turbine, based on which an integrated control strategy is developed for wind energy extraction, reactive power, and grid voltage support controls of the wind turbine. A transient simulation system using SimPower-System is built to validate the effectiveness of the proposed control method. The conventional control approach is compared with the proposed control technique for DFIG wind turbine control under both steady and gust wind conditions. The paper shows that under the dc vector control configuration, a DFIG system has a superior performance in various aspects.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 24 条
[1]  
Acha Enrique., 2004, FACTS MODELING SIMUL
[2]  
[Anonymous], 2006, DETAILED MODEL DOUBL
[3]   A Robust Predictive Current Control for Three-Phase Grid-Connected Inverters [J].
Castello Moreno, Jaime ;
Espi Huerta, Jose M. ;
Garcia Gil, Rafael ;
Alejandro Gonzalez, Sergio .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :1993-2004
[4]   Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters [J].
Dannehl, Joerg ;
Wessels, Christian ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) :380-388
[5]  
Giroux P., 2006, Static Synchronous Compensator (STATCOM) Used for Midpoint Voltage Regulation on a 500 kV Transmission Line
[6]  
Hansen A. D., 2004, Wind Engineering, V28, P411, DOI 10.1260/0309524042886441
[7]   Fault ride-through capability of DFIG wind turbines [J].
Hansen, Anca D. ;
Michalke, Gabriele .
RENEWABLE ENERGY, 2007, 32 (09) :1594-1610
[8]  
Haykin S., 1999, Neural Networks: A Comprehensive Foundation, DOI DOI 10.1017/S0269888998214044
[9]   Steady-State Characteristic Study for Integration of DFIG Wind Turbines into Transmission Grid [J].
Li, Shuhui ;
Haskew, Timothy A. ;
Challoo, Rajab .
INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2009, 10 (01)
[10]   Integrating electrical and aerodynamic characteristics for DFIG wind energy extraction and control study [J].
Li, Shuhui ;
Haskew, Timothy A. ;
Hong, Yang-Ki ;
Mazari, Shukul .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (12) :1052-1070