Effects of hot-wire length on the measurement of turbulent spectra in anisotropic flows

被引:14
作者
Cameron, J. D. [1 ]
Morris, S. C. [1 ]
Bailey, S. [2 ]
Smits, A. J. [2 ]
机构
[1] Univ Notre Dame, Dept Aerosp & Mech Engn, Notre Dame, IN 46530 USA
[2] Princeton Univ, Dept Mech & Aerosp Engn, Princeton, NJ 08540 USA
关键词
hot-wire; spatial filtering; anisotropy; turbulence; IMPERFECT SPATIAL-RESOLUTION; REGION; PIPE;
D O I
10.1088/0957-0233/21/10/105407
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Fluid velocity measurements obtained using hot-wire anemometry are subject to spatial filtering due to the finite length of the heated sensing element. This effect can lead to a negative bias error in the magnitude of the velocity fluctuations in turbulent flows when the smallest length scales of the flow are comparable to the wire length. Here an analytical model is used to provide a quantitative description of these errors in anisotropic flows. The model is then applied to a high Reynolds number pipe flow in which two hot-wire probes of different lengths were used to measure velocity spectra at three locations in the boundary layer. These data were used to estimate the anisotropy of the turbulence as a function of frequency (or streamwise wavenumber) and wall-normal distance.
引用
收藏
页数:10
相关论文
共 19 条
[1]  
Bruun HH., 1995, Hot-Wire Anemometry, Principles and Signal Analysis
[2]   Use of direct numerical simulation (DNS) data to investigate spatial resolution issues in measurements of wall-bounded turbulence [J].
Chin, C. C. ;
Hutchins, N. ;
Ooi, A. S. H. ;
Marusic, I. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (11)
[3]  
Comte-Bellot G., 2007, Springer handbook of experimental fluid mechanics
[4]   On the limitations of Taylor's hypothesis in constructing long structures in a turbulent boundary layer [J].
Dennis, David J. C. ;
Nickels, Timothy B. .
JOURNAL OF FLUID MECHANICS, 2008, 614 :197-206
[5]   EFFECT OF FINITE SPATIAL-RESOLUTION OF HOT-WIRE ANEMOMETRY ON MEASUREMENTS OF TURBULENCE ENERGY-DISSIPATION [J].
ELSNER, JW ;
DOMAGALA, P ;
ELSNER, W .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (04) :517-523
[6]   FREQUENCY-RESPONSE AND ELECTRONIC TESTING FOR CONSTANT-TEMPERATURE HOT-WIRE ANEMOMETERS [J].
FREYMUTH, P .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1977, 10 (07) :705-710
[7]   Evidence of very long meandering features in the logarithmic region of turbulent boundary layers [J].
Hutchins, N. ;
Marusic, Ivan .
JOURNAL OF FLUID MECHANICS, 2007, 579 :1-28
[8]   Hot-wire spatial resolution issues in wall-bounded turbulence [J].
Hutchins, N. ;
Nickels, T. B. ;
Marusic, I. ;
Chong, M. S. .
JOURNAL OF FLUID MECHANICS, 2009, 635 :103-136
[9]   EFFECTS OF IMPERFECT SPATIAL-RESOLUTION ON MEASUREMENTS OF WALL-BOUNDED TURBULENT SHEAR FLOWS [J].
JOHANSSON, AV ;
ALFREDSSON, PH .
JOURNAL OF FLUID MECHANICS, 1983, 137 (DEC) :409-421
[10]   Effects of imperfect spatial resolution on turbulence measurements in the very near-wall viscous sublayer region [J].
Khoo, BC ;
Chew, YT ;
Li, GL .
EXPERIMENTS IN FLUIDS, 1997, 22 (04) :327-335