Transcatheter Aortic and Mitral Valve-in-Valve Implantation Using the Edwards Sapien 3 Heart Valve

被引:27
作者
Shivaraju, Anupama [1 ,2 ]
Michel, Jonathan [1 ]
Frangieh, Antonio H. [1 ]
Ott, Ilka [1 ]
Thilo, Christian [3 ]
Schunkert, Heribert [1 ,4 ]
Kastrati, Adnan [1 ,4 ]
Leon, Martin B. [5 ]
Dvir, Danny [6 ]
Kodali, Susheel [5 ]
Bapat, Vinayak [5 ]
Guerrero, Mayra [7 ]
Kasel, Albert M. [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum Munchen, Dept Cardiovasc Dis, Munich, Germany
[2] Advocate Christ Med Ctr, Dept Cardiol, Oak Lawn, IL USA
[3] Herzzentrum Augsburg Schwaben, Klinikum Augsburg, Dept Cardiol, Augsburg, Germany
[4] DZHK, Munich Heart Alliance, Partner Site, Munich, Germany
[5] Columbia Univ, Div Cardiol, Med Ctr, New York, NY USA
[6] Univ Washington, Med Ctr, Seattle, WA 98195 USA
[7] Univ Chicago, Pritzker Sch Med, Evanston Hosp, NorthShore Univ Hlth Syst, Evanston, IL USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2018年 / 7卷 / 14期
关键词
aortic valve implantation; aortic valve replacement; mitral valve; Sapien; 3; transcatheter aortic valve replacement; transcatheter mitral valve replacement; transcatheter valve implantation; valve-in-valve; PROSTHESIS-PATIENT MISMATCH; BIOPROSTHETIC VALVE; CLINICAL IMPACT; REPLACEMENT; OBSTRUCTION; COREVALVE; RING;
D O I
10.1161/JAHA.117.007767
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页数:25
相关论文
共 39 条
[1]   Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion [J].
Abbasi, Mostafa ;
Azadani, Ali N. .
Journal of Biomechanics, 2015, 48 (13) :3663-3671
[2]   Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation [J].
Allen, Keith B. ;
Chhatriwalla, Adnan K. ;
Cohen, David J. ;
Saxon, John T. ;
Aggarwal, Sanjeev ;
Hart, Anthony ;
Baron, Suzanne ;
Davis, J. Russell ;
Pak, Alex F. ;
Dvir, Danny ;
Borkon, A. Michael .
ANNALS OF THORACIC SURGERY, 2017, 104 (05) :1501-1508
[3]  
[Anonymous], 2015, CIRC CARDIOVASC INTE
[4]   Valve-in-Valve Implantation Using a Novel Supravalvular Transcatheter Aortic Valve: Proof of Concept [J].
Azadani, Ali N. ;
Jaussaud, Nicolas ;
Matthews, Peter B. ;
Ge, Liang ;
Guy, T. Sloane ;
Chuter, Timothy A. M. ;
Tseng, Elaine E. .
ANNALS OF THORACIC SURGERY, 2009, 88 (06) :1864-1870
[5]  
Bapat V., 2009, VIV AORTIC APP
[6]   Neo-Annulus: A Reference Plane in a Surgical Heart Valve to Facilitate a Valve-in-Valve Procedure [J].
Bapat, Vinayak ;
Adams, Benjamin ;
Attia, Rizwan ;
Noorani, Alia ;
Thomas, Martyn .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (04) :685-691
[7]   A guide to fluoroscopic identification and design of bioprosthetic valves: A reference for valve-in-valve procedure [J].
Bapat, Vinayak ;
Mydin, Izanne ;
Chadalavada, Sucharitha ;
Tehrani, Hassan ;
Attia, Rizwan ;
Thomas, Martyn .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) :853-861
[8]   Effect of Valve Design on the Stent Internal Diameter of a Bioprosthetic Valve A Concept of True Internal Diameter and Its Implications for the Valve-in-Valve Procedure [J].
Bapat, Vinayak N. ;
Attia, Rizwan ;
Thomas, Martyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (02) :115-127
[9]   Factors Influencing Left Ventricular Outflow Tract Obstruction Following a Mitral Valve-in-Valve or Valve-in-Ring Procedure, Part 1 [J].
Bapat, Vinnie ;
Pirone, Francesco ;
Kapetanakis, Stam ;
Rajani, Ronak ;
Niederer, Steven .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (04) :747-760
[10]   Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? [J].
Bleiziffer, Sabine ;
Eichinger, Walter B. ;
Hettich, Ina ;
Guenzinger, Ralf ;
Ruzicka, Daniel ;
Bauernschmitt, Robert ;
Lange, Ruediger .
HEART, 2007, 93 (05) :615-620