3D laser scanning in conjunction with surface texturing to evaluate shift and reduction of the tibiofemoral contact area after meniscectomy

被引:11
|
作者
De Santis, Roberto [1 ]
Gloria, Antonio [1 ]
Viglione, Stefano [2 ]
Maietta, Saverio [3 ]
Nappi, Francesco [2 ]
Ambrosio, Luigi [1 ]
Ronca, Dante [1 ]
机构
[1] Natl Res Council Italy, Inst Polymers Composites & Biomat, Viale JF Kennedy,54 Mostra Oltremare Pad 20, I-80125 Naples, Italy
[2] Campania Univ Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Dent Sci, Via Luigi De Crecchio 4, I-80138 Naples, Italy
[3] Univ Naples Federico II, Fraunhofer JL IDEAS, Dept Ind Engn, Ple V Tecchio 80, I-80125 Naples, Italy
关键词
Biomechanics; Tibiofemoral contact area; Laser scanning; Image analysis; Surface texturing; Centroid; ARTICULAR-CARTILAGE; KNEE-ARTHROPLASTY; THICKNESS; JOINT; MODEL; MRI; BONE; VALIDATION; MECHANICS; SCAFFOLDS;
D O I
10.1016/j.jmbbm.2018.08.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Meniscectomy significantly change the kinematics of the knee joint by reducing the contact area between femoral condyles and the tibial plateau, but the shift in the contact area has been poorly described. The aim of our investigation was to measure the shift of the tibiofemoral contact area occurring after meniscectomy. We used laser scans combined to surface texturing for measuring the 3D position and area of the femoral and tibial surfaces involved in the joint. In particular, natural condyles (porcine model) were analysed and the reverse engineering approach was used for the interpretation of the results from compression tests and local force measurements in conjunction with staining techniques. The results suggested that laser scans combined to surface texturing may be considered as a powerful tool to investigate the stained contours of the contact area. Beside the largely documented reduction of contact area and local pressure increase, a shift of the centroid of the contact area toward the intercondylar notch was measured after meniscectomy. As a consequence of the contact area shift and pressure increase, cartilage degeneration close to the intercondylar notch may occur.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 21 条
  • [1] 3D Laser Scanning System for Rock Surface Measurement
    Liu Bin
    Sun Chang-ku
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: LASER SENSING AND IMAGING AND BIOLOGICAL AND MEDICAL APPLICATIONS OF PHOTONICS SENSING AND IMAGING, 2011, 8192
  • [2] Femtosecond laser surface texturing of 3D poly-ε-caprolactone matrices for bone tissue engineering applications
    Daskalova, A.
    Bliznakova, I.
    Zhelyazkova, A.
    Ostrowska, B.
    Trifonov, A.
    Buchvarov, I.
    Avramov, L.
    Husinsky, W.
    20TH INTERNATIONAL SUMMER SCHOOL ON VACUUM, ELECTRON AND ION TECHNOLOGIES, 2017, 2018, 992
  • [3] 3D Surface reconstruction of transparent objects using laser scanning with LTFtF method
    He, Kejing
    Sui, Congying
    Huang, Tianyu
    Dai, Rong
    Lyu, Congyi
    Liu, Yun-Hui
    OPTICS AND LASERS IN ENGINEERING, 2022, 148
  • [4] CAD-Based Path Planning for 3D Laser Scanning of Complex Surface
    Ding, Li-jun
    Dai, Shu-guang
    Mu, Ping-an
    2ND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING, COMMUNICATION & CONVERGENCE, ICCC 2016, 2016, 92 : 526 - 535
  • [5] Automated extraction of tunnel leakage location and area from 3D laser scanning point clouds
    Li, Pei
    Wang, Qiusheng
    Li, Jiahao
    Pei, Ying
    He, Peng
    OPTICS AND LASERS IN ENGINEERING, 2024, 178
  • [6] A novel method for approximating local changes in the surface absorption for laser marking using 3D laser scanning
    Mikkelstrup, Anders F.
    Thomsen, Anders N.
    Kristiansen, Morten
    18TH NORDIC LASER MATERIALS PROCESSING CONFERENCE (18TH NOLAMP), 2021, 1135
  • [7] 3D Laser Scanning Assisted by Ordinary Plane Mirror for Non-direct Viewing Area
    Zhang F.
    Huang Y.
    Huang X.
    Xu S.
    Huang, Xianfeng (hwangxf@qq.com), 1950, SinoMaps Press (46): : 1950 - 1958
  • [8] Surface area coverage of four extra-oral 3D scanning strategies for edentulous arches
    Alajmi, S.
    Muhanna, H.
    Alfozan, M.
    Asadallah, M.
    Alkhamees, Z.
    Wu, J.
    Khalid, S.
    Osnes, C.
    Hyde, T. P.
    Keeling, A.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : S279 - S284
  • [9] Deformation measurement using terrestrial laser scanning data and least squares 3D surface matching
    Monserrat, O.
    Crosetto, M.
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2008, 63 (01) : 142 - 154
  • [10] Application of laser scanning for developing a 3D digital model of an open-pit side surface
    Oparin, V. N.
    Seredovich, V. A.
    Yushkin, V. F.
    Ivanov, A. V.
    Prokop'eva, S. A.
    JOURNAL OF MINING SCIENCE, 2007, 43 (05) : 545 - 554