Depth Analysis of Planar Array for 3D Electrical Impedance Tomography

被引:9
作者
Chen, Bo [1 ]
Soleimani, Manuchehr [1 ]
机构
[1] Univ Bath, Elect & Elect Engn Dept, ETL, Bath BA1 7AY, Avon, England
关键词
Electrical resistance tomography; image reconstruction; total generalized variation; ELECTRODE MODELS; RECONSTRUCTION;
D O I
10.1109/JSEN.2019.2929625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) imaging modality has great potential on industrial applications with the advantages of being high temporal resolution. It is especially useful in cases, such as geophysical detection, landmine detection, and detections on non-transparent region, where the measurement data are only available from single surface, for data acquisition. Instead of the circular EIT model that uses the traditional circular electrode model, in this paper, planar array EIT is implemented, aiming to visualize a pipeline transporting a two-phase flow. The planar array can explore spatial information within its detectable region by producing 3D images, which have a higher spatial resolution in the axis direction than a traditional EIT with a dual-plane electrode sensor. However, in solving the inverse problem of a 3D subsurface EIT using a planar array, the images may be degraded, especially in cases where the location of the target is relatively deep. The total variation (TV) algorithm as block prior assumption-based regularization method has the potential to improve the image quality, and some works have shown that TV reconstructs sharper images, which provides an advantage when representing spatial information. In this paper, the performance of subsurface EIT using the TV algorithm for 3D visualization is presented based on simulations and experiments, and the results of quantitative measurement of depth are discussed.
引用
收藏
页码:10710 / 10718
页数:9
相关论文
共 22 条
[1]   Electrical impedance tomography reconstruction for three-dimensional imaging of the prostate [J].
Borsic, A. ;
Halter, R. ;
Wan, Y. ;
Hartov, A. ;
Paulsen, K. D. .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) :S1-S16
[2]   Reconstruction of inhomogeneities in fluids by means of capacitance tomography [J].
Brandstätter, B ;
Holler, G ;
Watzenig, D .
COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2003, 22 (03) :508-519
[3]  
Cheney M, 1990, Int J Imaging Syst Technol, V2, P66, DOI 10.1002/ima.1850020203
[4]   ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
CHENG, KS ;
ISAACSON, D ;
NEWELL, JC ;
GISSER, DG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) :918-924
[5]   An electrical impedance tomography system for gynecological application GIT with a tiny electrode array [J].
Cherepenin, V. A. ;
Gulyaev, Y., V ;
Korjenevsky, A., V ;
Sapetsky, S. A. ;
Tuykin, T. S. .
PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) :849-862
[6]   The Split Bregman Method for L1-Regularized Problems [J].
Goldstein, Tom ;
Osher, Stanley .
SIAM JOURNAL ON IMAGING SCIENCES, 2009, 2 (02) :323-343
[7]  
Holder D., 2005, ELECT IMPEDANCE TOMO, P23
[8]   Total Variation Regularization With Split Bregman-Based Method in Magnetic Induction Tomography Using Experimental Data [J].
Li, Fang ;
Abascal, Juan F. P. J. ;
Desco, Manuel ;
Soleimani, Manuchehr .
IEEE SENSORS JOURNAL, 2017, 17 (04) :976-985
[9]   Image reconstruction by nonlinear Landweber iteration for complicated distributions [J].
Li, Yi ;
Yang, Wuqiang .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
[10]   Reconstruction of conductivity changes due to ventilation and perfusion from EIT data collected on a rectangular electrode array [J].
Mueller, JL ;
Isaacson, D ;
Newell, JC .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :97-106