Split-bolus single scan CTA for evaluation of mesenteric ischemia

被引:7
作者
Jo, Patricia C. [1 ]
Cabral, Fernanda C. [1 ]
Sahin, Azize [1 ]
Camacho, Andres [1 ]
Brook, Alexander [1 ]
Brook, Olga R. [1 ]
机构
[1] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Radiol, 330 Brookline Ave,1 Deaconess Rd,WCC-3, Boston, MA 02215 USA
关键词
Mesenteric ischemia; diagnostic imaging; computed tomography; split-bolus; MULTIDETECTOR ROW CT; CONTRAST-ENHANCED CT; MDCT UROGRAPHY; OPACIFICATION; ANGIOGRAPHY; DIAGNOSIS; PERFORMANCE; HEMATURIA; MORTALITY; ACCURACY;
D O I
10.1007/s00261-017-1333-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate split-bolus single scan CTA protocol for evaluation of acute mesenteric ischemia. Materials and methods: In this HIPAA-compliant IRB-approved study, consecutive patients evaluated for mesenteric ischemia between 11/2015 and 10/2016 were included. Patients scanned prior to 4/2016 were scanned with multiphasic CTA protocol and after with split-bolus single scan CTA. Objective and subjective evaluation was performed by three board-certified readers. Findings were correlated to composite clinical reference outcome. Results: Eighty patients were included: 40 with split-bolus and 40 with multiphasic CTA protocol with similar age (60.3 +/- 16.2 years vs. 64.7 +/- 17.0 years, p = 0.19) and BMI (28.0 +/- 6.7 vs. 27.0 +/- 8.7, p = 0.56). SMA attenuation was higher in multiphasic protocol compared to split-bolus protocol (336.5 +/- 97.5 HU vs. 258.0 +/- 67.3 HU, p < 0.001) with similar SMV attenuation (multiphasic 213.7 +/- 58.4 HU vs. split-bolus 194.2 +/- 52.2 HU, p = 0.14). Optimal phase of bowel, liver, and spleen enhancement was seen in similar high proportion (94-99%) in both protocols. There were 8/40 (20%) positive cases of mesenteric ischemia in each group. There was no difference in the diagnostic confidence of the readers for evaluation of the mesenteric vessels and bowel ischemia. There were no missed cases of mesenteric ischemia in either group. Mean effective dose was 42% lower in the split-bolus group, p < 0.001. There was a higher number of axial images to review in multiphasic protocol compared to split-bolus protocol (437.9 +/- 48.7 vs. 263.5 +/- 31.2, p < 0.001). Conclusions: The split-bolus protocol for evaluation of mesenteric ischemia is clinically feasible with confident and accurate diagnostic ability, while reducing number of images and decreasing radiation exposure to the patient.
引用
收藏
页码:1368 / 1378
页数:11
相关论文
共 30 条
[1]  
[Anonymous], 2017, ACR MAN CONTR MED VE
[2]   Evaluation of acute mesenteric ischemia: accuracy of biphasic mesenteric multi-detector CT angiography [J].
Aschoff, A. J. ;
Stuber, G. ;
Becker, B. W. ;
Hoffmann, M. H. K. ;
Schmitz, B. L. ;
Schelzig, H. ;
Jaeckle, T. .
ABDOMINAL IMAGING, 2009, 34 (03) :345-357
[3]  
Boos J, 2017, ABDOM RADIOL, P1
[4]  
Boos J, 2017, AJR AM J ROENTGENOL
[5]  
Brady Adrian, 2012, Ulster Med J, V81, P3
[6]   Split-Bolus Spectral Multidetector CT of the Pancreas: Assessment of Radiation Dose and Tumor Conspicuity [J].
Brook, Olga R. ;
Gourtsoyianni, Sofia ;
Brook, Alexander ;
Siewert, Bettina ;
Kent, Tara ;
Raptopoulos, Vassilios .
RADIOLOGY, 2013, 269 (01) :139-148
[7]   Diagnostic Performance of Split-Bolus Portal Venous Phase Dual-Energy CT Urography in Patients With Hematuria [J].
Chen, Chiao-Yun ;
Tsai, Tzu-Hsueh ;
Jaw, Twei-Shiun ;
Lai, Ming-Lai ;
Chao, Min-Fang ;
Liu, Gin-Chung ;
Hsu, Jui-Sheng .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (05) :1013-1022
[8]   Split-bolus MDCT urography with synchronous nephrographic and excretory phase enhancement [J].
Chow, Lawrence C. ;
Kwan, Sharon W. ;
Olcott, Eric W. ;
Sommer, Graham .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) :314-322
[9]   Assessment of Bowel Wall Enhancement for the Diagnosis of Intestinal Ischemia in Patients with Small Bowel Obstruction: Value of Adding Unenhanced CT to Contrast-enhanced CT [J].
Chuong, Anh Minh ;
Corno, Lucie ;
Beaussier, Helesne ;
Boulay-Coletta, Isabelle ;
Millet, Ingrid ;
Hodel, Jerone ;
Taourel, Patrice ;
Chatellier, Gilles ;
Zins, Marc .
RADIOLOGY, 2016, 280 (01) :98-107
[10]   Comparison of urinary tract distension and opacification using single-bolus 3-phase vs split-bolus 2-phase multidetector row CT urography [J].
Dillman, Jonathan R. ;
Caoili, Elaine M. ;
Cohan, Richard H. ;
Ellis, James H. ;
Francis, Isaac R. ;
Nan, Bin ;
Zhang, Yong .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (05) :750-757