Transient modeling of zinc extraction with D2EHPA in a Kuhni column

被引:19
作者
Neto, Artur Pereira [1 ]
Mansur, Marcelo Borges [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Met & Mat Engn, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Zinc extraction; D2EHPA; Kuhni column; Back-mixing; Forward-mixing; POPULATION BALANCE EQUATION; DROP-SIZE DISTRIBUTION; PHASE HOLD-UP; MASS-TRANSFER; LIQUID; PREDICTION; HYDRODYNAMICS;
D O I
10.1016/j.cherd.2013.05.014
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The transient extraction of zinc sulfate with D2EHPA (di-2-ethylhexyl phosphoric acid) in a section of a Kuhni column operated with total recirculation of liquid phases was modeled using the back-mixing and the forward-mixing approaches. The mathematical developments for both models as well as their numerical solutions are given in detail. Operating parameters were calculated using recommended correlations available in the literature and simulations were confronted with experimental data. Both models revealed to describe column operation adequately under evaluated conditions. In addition, as back-mixing and forward-mixing approaches are particularly equivalent in very stirred conditions, the former approach seems to be more advantageous to describe practical situations due to its simplicity in comparison to the later approach. (C) 2013 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:2323 / 2332
页数:10
相关论文
共 43 条
[11]   Copper extraction from ammoniacal medium in a pulsed sieve-plate column with LIX 84-I [J].
Gameiro, M. Lurdes F. ;
Machado, Remigio M. ;
Ismael, M. Rosinda C. ;
Reis, M. Teresa A. ;
Carvalho, Jorge M. R. .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 183 (1-3) :165-175
[12]  
GAYLER R., 1951, T I CHEM ENG-LOND, V29, P110
[13]  
Godfrey J.C., 1994, LIQUID LIQUID EXTRAC
[14]  
GOLDMANN G, 1986, THESIS TU MUNCHEN MU
[15]  
GOURDON C, 1994, LIQUID LIQUID EXTRAC, P137
[16]   Review article: The existing models for simulation of pulsed and reciprocating Columns - How well do they work in the real world? [J].
Grinbaum, B. .
SOLVENT EXTRACTION AND ION EXCHANGE, 2006, 24 (06) :795-822
[17]  
Haverland H., 1987, Chem. Eng. Technol, V10, P151, DOI [10.1002/ceat.270100119, DOI 10.1002/CEAT.270100119]
[18]   DROP-SIZE DISTRIBUTION AND DISPERSED PHASE HOLD-UP IN A LARGE ROTATING-DISK CONTACTOR [J].
JEFFREYS, GV ;
ALASWAD, KKM ;
MUMFORD, CJ .
SEPARATION SCIENCE AND TECHNOLOGY, 1981, 16 (09) :1217-1245
[19]  
KORCHINSKY WJ, 1993, J CHEM TECHNOL BIOT, V58, P113
[20]   FORWARD MIXING MODEL - APPLICATION TO PULSED PLATE EXTRACTION COLUMN OPERATION IN THE EMULSION REGION [J].
KORCHINSKY, WJ ;
SHEIKH, QM .
CHEMICAL ENGINEERING COMMUNICATIONS, 1992, 115 :95-115