Multi-channel deep tissue flowmetry based on temporal diffuse speckle contrast analysis

被引:51
作者
Bi, Renzhe [1 ]
Dong, Jing [1 ]
Lee, Kijoon [1 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 637457, Singapore
关键词
CEREBRAL-BLOOD-FLOW; LOW-FREQUENCY OSCILLATIONS; CORRELATION SPECTROSCOPY; HEMODYNAMICS; VALIDATION; DYNAMICS; INFANTS; TIME;
D O I
10.1364/OE.21.022854
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, diffuse speckle contrast analysis (DSCA) was introduced as a competent modality for deep tissue blood flow measurement, where the speckle contrast is calculated over spatial domain on the CCD image of diffuse reflectance. In this paper, we introduce time-domain DSCA where temporal statistics are used for speckle contrast calculation and results in the same deep tissue flow measurement. This new modality is especially suitable for multi-channel real-time flowmetry, and we demonstrate its performance on human arm during cuff occlusion test. Independent component analysis (ICA) study on multi-channel data shows promising results about underlying physiology. (c) 2013 Optical Society of America
引用
收藏
页码:22854 / 22861
页数:8
相关论文
共 33 条
[1]   Speckle-visibility spectroscopy: A tool to study time-varying dynamics [J].
Bandyopadhyay, R ;
Gittings, AS ;
Suh, SS ;
Dixon, PK ;
Durian, DJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09)
[2]   Deep tissue flowmetry based on diffuse speckle contrast analysis [J].
Bi, Renzhe ;
Dong, Jing ;
Lee, Kijoon .
OPTICS LETTERS, 2013, 38 (09) :1401-1403
[3]   Laser speckle contrast imaging in biomedical optics [J].
Boas, David A. ;
Dunn, Andrew K. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
[4]  
Briers J D, 1996, J Biomed Opt, V1, P174, DOI 10.1117/12.231359
[5]   Sodium bicarbonate causes dose-dependent increases in cerebral blood flow in infants and children with single-ventricle physiology [J].
Buckley, Erin M. ;
Naim, Maryam Y. ;
Lynch, Jennifer M. ;
Goff, Donna A. ;
Schwab, Peter J. ;
Diaz, Laura K. ;
Nicolson, Susan C. ;
Montenegro, Lisa M. ;
Lavin, Natasha A. ;
Durduran, Turgut ;
Spray, Thomas L. ;
Gaynor, J. William ;
Putt, Mary E. ;
Yodh, A. G. ;
Fogel, Mark A. ;
Licht, Daniel J. .
PEDIATRIC RESEARCH, 2013, 73 (05) :668-673
[6]   Validation of diffuse correlation spectroscopic measurement of cerebral blood flow using phase-encoded velocity mapping magnetic resonance imaging [J].
Buckley, Erin M. ;
Hance, Dalton ;
Pawlowski, Thomas ;
Lynch, Jennifer ;
Wilson, Felice B. ;
Mesquita, Rickson C. ;
Durduran, Turgut ;
Diaz, Laura K. ;
Putt, Mary E. ;
Licht, Daniel J. ;
Fogel, Mark A. ;
Yodh, Arjun G. .
JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (03)
[7]   Cerebral hemodynamics in preterm infants during positional intervention measured with diffuse correlation spectroscopy and transcranial Doppler ultrasound [J].
Buckley, Erin M. ;
Cook, Noah M. ;
Durduran, Turgut ;
Kim, Meeri N. ;
Zhou, Chao ;
Choe, Regine ;
Yu, Guoqiang ;
Shultz, Susan ;
Sehgal, Chandra M. ;
Licht, Daniel J. ;
Arger, Peter H. ;
Putt, Mary E. ;
Hurt, Hallam ;
Yodh, Arjun G. .
OPTICS EXPRESS, 2009, 17 (15) :12571-12581
[8]   Validation of diffuse correlation spectroscopy measurements of rodent cerebral blood flow with simultaneous arterial spin labeling MRI; towards MRI-optical continuous cerebral metabolic monitoring [J].
Carp, S. A. ;
Dai, G. P. ;
Boas, D. A. ;
Franceschini, M. A. ;
Kim, Y. R. .
BIOMEDICAL OPTICS EXPRESS, 2010, 1 (02) :553-565
[9]   Temporal statistical analysis of laser speckle images and its application to retinal blood-flow imaging [J].
Cheng, Haiying ;
Yan, Yumei ;
Duong, Timothy Q. .
OPTICS EXPRESS, 2008, 16 (14) :10214-10219
[10]   Noninvasive optical evaluation of spontaneous low frequency oscillations in cerebral hemodynamics [J].
Cheng, Ran ;
Shang, Yu ;
Hayes, Don, Jr. ;
Saha, Sibu P. ;
Yu, Guoqiang .
NEUROIMAGE, 2012, 62 (03) :1445-1454