Natural compounds analysis using liquid and supercritical fluid chromatography hyphenated to mass spectrometry: Evaluation of a new design of atmospheric pressure ionization source

被引:17
作者
Ciclet, Oliver [1 ]
Barron, Denis [2 ]
Bajic, Steve [3 ]
Veuthey, Jean-Luc [1 ]
Guillarme, Davy [1 ]
Perrenoud, Alexandre Grand-Guillaume [2 ]
机构
[1] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, CMU Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
[2] Ecole Polytech Fed Lausanne, Nestle Inst Hlth Sci, Nat Bioact & Screening, Innovat Pk,H, CH-1015 Lausanne, Switzerland
[3] Waters Corp, Stamford Ave,Altrincham Rd, Wilmslow SK9 4AX, Cheshire, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2018年 / 1083卷
关键词
UniSpray ionization; RPLC-MS; SFC-MS; QqTOE-MS; Natural compounds; PHARMACEUTICAL ANALYSIS; SMALL-PARTICLE; METABOLOMICS; PRODUCTS; INTERFACE;
D O I
10.1016/j.jchromb.2018.02.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The MS hyphenation performance of UniSpray (R), a new design of atmospheric pressure ionization source was evaluated in both SFC and RPLC modes. Sensitivity, stability, versatility and matrix effects offered by the UniSpray were assessed in positive and negative ionization modes and systematically compared to an electrospray source (ESI) using 120 natural compounds covering an extended chemical space. In a first instance, a multivariate approach was used to screen and optimize the UniSpray source settings to maximize detection sensitivity. The position of the source capillary against the fixed charged rod was highlighted as the major parameter affecting the detection sensitivity. The sensitivity improvement in Unispray vs. ESI strongly depends on the compounds chemical class and the chromatographic mode. For a few compounds (i.e. anabasine, theanine, caproic acid, fumaric acid and protopanaxatriol), up to a 10-fold increase in sensitivity was noticed with UniSpray. The signal stability over multiple injections was also found to be equivalent between both sources with RSD values on peak intensity lower than 14% on > 100 injections, in both chromatographic modes. On complex plant extract, the matrix effects occurring from the secondary metabolites were also found to be comparable between ESI and UniSpray, at least in the positive ionization mode. However, a systematic decrease of MS signal intensity was observed in SFC mode when compounds were ionized using UniSpray in the negative ion mode.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 18 条
[1]   Functional components and medicinal properties of food: a review [J].
Abuajah, Christian Izuchukwu ;
Ogbonna, Augustine Chima ;
Osuji, Chijioke Maduka .
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2015, 52 (05) :2522-2529
[2]   Integration of Molecular Networking and In-Silico MS/MS Fragmentation for Natural Products Dereplication [J].
Allard, Pierre-Marie ;
Peresse, Tiphaine ;
Bisson, Jonathan ;
Gindro, Katia ;
Marcourt, Laurence ;
Van Cuong Pham ;
Roussi, Fanny ;
Litaudon, Marc ;
Wolfender, Jean-Luc .
ANALYTICAL CHEMISTRY, 2016, 88 (06) :3317-3323
[3]   Cancer Prevention With Natural Compounds [J].
Collett, Norleena P. ;
Amin, A. R. M. Ruhul ;
Bayraktar, Soley ;
Pezzuto, John M. ;
Shin, Dong M. ;
Khuri, Fadlo R. ;
Aggarwal, Bharat B. ;
Surh, Young-Joon ;
Kucuk, Omer .
SEMINARS IN ONCOLOGY, 2010, 37 (03) :258-281
[4]  
Dumitrache A., 2012, MATH MODELLING INVES
[5]   Method transfer for fast liquid chromatography in pharmaceutical analysis: Application to short columns packed with small particle. Part II: Gradient experiments [J].
Guillarme, Davy ;
Nguyen, Dao T. T. ;
Rudaz, Serge ;
Veuthey, Jean-Luc .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2008, 68 (02) :430-440
[6]   Method transfer for fast liquid chromatography in pharmaceutical analysis: Application to short columns packed with small particle. Part I: Isocratic separation [J].
Guillarme, Davy ;
Nguyen, Dao T. -T. ;
Rudaz, Serge ;
Veuthey, Jean-Luc .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2007, 66 (03) :475-482
[7]   Natural products in drug discovery [J].
Harvey, Alan L. .
DRUG DISCOVERY TODAY, 2008, 13 (19-20) :894-901
[8]   Atmospheric Pressure Ionization Using a High Voltage Target Compared to Electrospray Ionization [J].
Lubin, Arnaud ;
Bajic, Steve ;
Cabooter, Deirdre ;
Augustijns, Patrick ;
Cuyckens, Filip .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (02) :286-293
[9]   Enhanced performance for the analysis of prostaglandins and thromboxanes by liquid chromatography-tandem mass spectrometry using a new atmospheric pressure ionization source [J].
Lubin, Arnaud ;
Geerinckx, Suzy ;
Bajic, Steve ;
Cabooter, Deirdre ;
Augustijns, Patrick ;
Cuyckens, Filip ;
Vreeken, Rob J. .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1440 :260-265
[10]   Metabolomics technologies and metabolite identification [J].
Moco, Sofia ;
Bino, Raoul J. ;
De Vos, Ric C. H. ;
Vervoort, Jacques .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (09) :855-866